5-13
1. HALL Adjustment
For detecting the position of lens iris, adjust the HALL AMP
gain and offset.
Mode
STILL
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 2)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
2E, 2F, 34, 35
Specified Value
13 to 17 during IRIS OPEN
7B to 7F during IRIS CLOSE
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
The right two digits of the page: 1 displayed data of the
adjusting remote commander.
1:00:XX
    
Displayed data
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Select page: 6, address: 94, and set data: 15.
5)
Select page: 6, address: 95, and set data: 7D.
6)
Select page: 6, address: 01, set data: 6D, and press the PAUSE
button. (The HALL adjustment is performed and the adjustment
data is stored in page: F, addresses: 2E, 2F, 34 and 35)
7)
Select page: 6, address: 02, and check that the data is “01”.
8)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1)
Select page: 0, address: 03, and set data: 03.
2)
Select page: 6, address: 01,  set data: 01, and press the PAUSE
button of the adjusting remote commander.
3)
Select page: 1, and check that the displayed data (Note 2) during
IRIS OPEN satisfies the specified value.
4)
Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
5)
Select page: 1, and check that the displayed data (Note 2) during
IRIS CLOSE satisfies the specified value.
Processing after Completing Adjustments:
1)
Select page: 0, address: 03, and set data: 00.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
3)
Select page: 6, address: 95, and set data: 00.
4)
Select page: 6, address: 94, and set data: 00.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
7)
Select page: 0, address: 01, and set data: 00.
1-4. CAMERA SYSTEM ADJUSTMENT
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
5-14
Fig. 5-1-12
Adjusting method:
1)
Install the minipattern box so that the distance between it
and the front of lens of the camera is less than 3cm.
2)
Make the height of minipattern box and the camera equal.
3)
Check the output voltage of the regulated power supply is
the specified voltage ± 0.01 Vdc.
4)
Check that the center of Siemens star chart meets the center
of shot image screen with the zoom lens at TELE end and
WIDE end respectively.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: 5, address: F1, and set data: FF.
7)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
8)
Check that the data on page: F, addresses: 14 to 25 are initial
values (See table below).
9)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button.
10) Select page: 6, address: 01, set data: 27, and press the PAUSE
button. (The flange back adjustment is performed and the
adjustment data is stored in page: F, addresses: 14 to 25)
11) Select page: 6, address: 02, and check that the data is “01”.
Processing after completion of adjustment:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
4)
Select page: 0, address: 01, and set data: 00.
5)
Perform “Flange Back Check”.
2. Flange Back Adjustment
(Using the minipattern box)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual forcusing.
Mode
STILL
Subject
 Siemens star chart with ND filter
 for minipattern box (Note 1)
Measurement Point
 Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
14 to 25
Note 1:
 Dark Siemens star chart.
Note 2:
 Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Preparations before adjustments:
The minipattern box is installed as shown in the following figure.
Note 3:
The attachment lenses are not used.
Note 4:
Take care not to hit the mini-pattern box when extending
the lens.
Specified voltage: The specified voltage varies according to the
minipatternbox, so adjustment the power sup
ply output voltage to the specified voltage
written on the sheet which is supplied with the
minipattern box.
Minipattern box
Below 3 cm
Camera
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01 Vdc
Output current : more than 3.5 A
Address
Data
Address
Data
14
1C
1D
00
15
94
1E
46
16
26
1F
00
17
EC
20
20
18
13
21
20
19
B9
22
20
1A
00
23
44
1B
00
24
0A
1C
00
25
00
5-15
3. Flange Back Check
Mode
STILL
Subject
 Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
 Check operation on TV monitor
Measuring Instrument
Specified value
Focused at the TELE end and
WIDE end
Checking method:
1)
Place the Siemens star 2.0 m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: 5, address: F1, and set data: FF.
5)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
6)
Shoot the Siemens star with the zoom TELE end.
7)
Turn on the auto focus.
8)
Check that the lens is focused.
9)
Select page: 6, address: 2C, and set data: 01.
10) While observe the TV monitor, change the zoom to the WIDE
end and check that the lens is focused.
Processing after completion of adjustment:
1)
Select page: 6, address: 2C, and set data: 00.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button of the adjusting remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5-16
4. F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
STILL
Subject
Clear chart
(10 cm from the front of the lens)
Adjustment Page
F
Adjustment Address
29 to 2D
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Adjusting method:
1)
Shoot the Clear chart with the zoom WIDE end.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
5)
Select page: E, address: 51, after noting down the data, set
data: FF, and press the PAUSE button.
6)
Select page: 6, address: 01, set data: BB, and press the PAUSE
button. (The F No. standard data input is performed and the
standard data is stored in page: F, addresses: 29 to 2D)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2)
Select page: E, address: 51, set data noted down at step 5)
and press the PAUSE button.
3)
Select page: 5, address: F1, and set data: 00.
4)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
5)
Select page: 0, address: 01, and set data: 00.
5. Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed,
and compensate the exposure.
Mode
STILL
Subject
Clear chart
(10 cm from the front of the lens)
Adjustment Page
F
Adjustment Address
5A, 6C to 7F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Adjusting method:
1)
Shoot the Clear chart with the zoom WIDE end.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
5)
Select page: 6, address: 01, set data: AD, and press the PAUSE
button. (The mechanical shutter adjustment is performed and
the adjustment data is stored in page: F, addresses: 5A and
6C  to 7F)
6)
Select page: 6, address: 02, and check that the data is “01”.
7)
Select page: 6, address: AB, and check that the data is “00”.
(If the data other than “00”, mechanical shutter adjustment
has errors)
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
4)
Select page: 0, address: 01, and set data: 00.