Model
DSC-F505V (serv.man2)
Pages
109
Size
9.58 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-f505v-sm2.pdf
Date

Sony DSC-F505V (serv.man2) Service Manual ▷ View online

5-17
6. Picture Frame Setting
Mode
STILL
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video terminal of A/V OUT jack
(75 
 terminated)
Measuring Instrument Oscilloscope and TV monitor
Specified Value
A = B, C = D, E = F
Check on the oscilloscope
1. Horizontal period
Fig. 5-1-13
2. Vertical period
Fig. 5-1-14
Check on the TV monitor
Fig. 5-1-15
A=B
C=D
A
B
C
D
Color bar chart picture frame
TV monitor picture frame
E=F
V
E
F
Note 1:
 Displayed data of page 1 of adjusting remote commander.
1:XX:XX

  XL or YL data
  
XH or YH data
Setting method:
1)
Select page: 5, address: F1, and set data: FF.
2)
Adjust the zoom and the camera direction, and set to the pic-
ture frame to the specified position.
3)
Mark the position of the picture frame on the TV monitor,
and adjust the picture frame to this position in following ad-
justments using “Color reproduction adjustment frame”.
4)
Select page: 0, address: 03, and set data: 18.
5)
Select page: 1, and note down the XH and XL data. (Note 1)
6)
Select page: 0, address: 03, and set data: 22.
7)
Select page: 1, and note down the YH and YL data. (Note 1)
8)
Select page: 5, address: F1, and set data: 00.
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
1)
Select page: 6, address: 90, and set data: XL. (Note 2)
2)
Select page: 6, address: 91, and set data: XH. (Note 2)
3)
Select page: 6, address: 92, and set data: YL. (Note 3)
4)
Select page: 6, address: 93, and set data: YH. (Note 3)
5)
Select page: 6, address: 01, set data: 79, press the PAUSE
button.
6)
Wait for 1 second.
7)
Select page: 6, address: 2C, and set data: 01.
8)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Note 2:
 The data noted down at step 5) of “Setting method”.
Note 3:
 The data noted down at step 7) of “Setting method”.
5-18
7. Light Level Adjustment and ND  Shutter Check
Adjust the standard LV value.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Displayed data of page: 1 (Note 2)
Measuring Instrument Adjusting remote commander
Adjustment Page
F
Adjustment Address
26, 28
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: Below 1100
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
 
Displayed data
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Select page: 6, address: 01, set data: 0D, and press the PAUSE
button. (The light level adjustment is performed and the ad-
justment data is stored in page: F, addresses: 26 and 28)
5)
Select page: 6, address: 02, and check that the data is “01”.
6)
Select page: 0, address: 03, and set data: 06.
7)
Select page: 1, and check that the displayed data (Note 2)
satisfies the AE level 1 specified value.
8)
Select page: E, address: 41, set data: 6B, and press the PAUSE
button.
9)
Select page: 6, address: 1C, and set data: 03.
10) Select page: 1, and check that the displayed data (Note 2)
satisfies the AE level 2 specified value.
Processing after Completing Adjustments:
1)
Select page: 6, address: 1C, and set data: 00.
2)
Select page: E, address: 41, set data: 6A, and press the PAUSE
button of the adjusting remote commander.
3)
Select page: 0, address: 03, and set data: 00.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
7)
Select page: 0, address: 01, and set data: 00.
8. Mixed Color Cancel Adjustment
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
STILL
Subject
Color bar chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address A0 to A3
Note 1:
Perform “Light Level Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Select page: 6, address: 01, set data: D7, and press the PAUSE
button.
5)
Select page: 6, address: 01, set data: D5, and press the PAUSE
button. (The mixed color adjustment is performed and the
adjustment data is stored in page: F, addresses: A0 to A3)
6)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
4)
Select page: 0, address: 01, and set data: 00.
5-19
9. Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
3A to 3D, 59
Note 1:
Perform “Light Level Adjustment” and “Mixed Color
Cancel Adjustment” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button.
5)
Select page: 6, address: 01, set data: 0B, and press the PAUSE
button. (The auto white balance standard data input is per-
formed and the standard data is stored in page: F, addresses:
3A to 3D, 59)
6)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
4)
Select page: 0, address: 01, and set data: 00.
5)
Perform “Auto White Balance Adjustment”.
10. Auto White Balance ND Filter Compensation
Adjust to the proper auto white balance output data with Built-in
ND filter.
If it is not correct, auto white balance and color reproducibility
will be poor.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
4F, 50
Note 1:
Perform “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If
not, turn the power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Select page: 6, address: 1C, set data: 03, and press the PAUSE
button.
5)
Wait for 1 second.
6)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button.
7)
Select page: 6, address: 01, set data: 09, and press the PAUSE
button.
(The auto white balance adjustment ND filter compensation is
performed and the adjustment data is stored in page: F,
addresses: 4F and 50)
8)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 1C, and set data: 00.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
3)
Select page: 5, address: F1, and set data: 00.
4)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
6)
Select page: 0, address: 01, and set data: 00.
5-20
11. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument Adjusting remote commander
Adjustment Page
F
Adjustment Address
3F, 40, 80
Specified Value
R ratio: 2820 to 2A60
B ratio: 5DA0 to 5EE0
Note 1:
Perform “Auto White Balance Standard Data Input” and
“Auto White Balance ND Filter Compensation” before
this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
 
Displayed data
Adjusting method:
1)
Place the C14 filter for color temperature correction on the
lens.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
5)
Select page: 6, address: 01, set data: A7, and press the PAUSE
button.
6)
Select page: F, addresses: 49 to 4C, and noting down the data
of each address.
7)
Write data in page: F, addresses: 49 to 4C as shown in the
following table.
Adderss
49
4A
4B
4C
Data
29
C0
5E
40
Note:
After setting each data, be sure to press the PAUSE button
of the adjusting remote commander.
8)
Select page: 6, address: 01, set data: A5, and press the PAUSE
button. (The auto white balance adjustment is performed and
the adjustment data is stored in page: F, addresses: 3F, 40
and 80)
9)
Select page: 6, address: 02, and check that the data is “01”.
10) Select page: 6, address: 01, set data: 3F, and press the PAUSE
button.
11) Select page: 0, address: 03, and set data: 04.
12) Select page: 1, and check that the displayed data (Note 3)
satisfies the R ratio specified value.
13) Select page: 0, address: 03, and set data: 05.
14) Select page: 1, and check that the displayed data (Note 3)
satisfies the B ratio specified value.
15) Select page: F, addresses: 49 to 4C, and input the data noted
down at step 6).
Note:
After setting each data, be sure to press the PAUSE button
of the adjusting remote commander.
Processing after Completing Adjustments:
1)
Select page: 0, address: 03, and set data: 00.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
3)
Select page: 5, address: F1, and set data: 00.
4)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
5)
Select page: 0, address: 01, and set data: 00.