Sony XAV-701HD Service Manual ▷ View online
XAV-701HD
25
SECTION 4
ELECTRICAL ADJUSTMENTS
MONITOR SECTION
If any of the following parts was replaced, execute the “Flicker
Adjustment” as mentioned below.
•
Adjustment” as mentioned below.
•
Liquid crystal display panel (LCD1)
•
Complete DISP board
1. SETTINGS
1-1. Tools and measuring devices for adjustment
1-1. Tools and measuring devices for adjustment
Note: This adjustment can be operated even if it is remote commander
which is not attached remote commander.
Tools and measuring devices
Item used
PC
(The one with serial port. The USB-
RS232C conversion is available.)
(The one with serial port. The USB-
RS232C conversion is available.)
Flicker adjustment
Communication software
(Hyper Terminal etc.)
(Hyper Terminal etc.)
Serial cable for RS232C
(Cross cable)
(Cross cable)
RS232-JIG OVERALL ASSY
(Part No. A-1777-380-A)
(Part No. A-1777-380-A)
RS232-JIG OVERALL ASSY
1-2.
Serial port setting
Please setting it as follows.
1-3. Connection with unit
Procedure:
1. Remove cover referring to “3. DISASSEMBLY (Page 9 to
Procedure:
1. Remove cover referring to “3. DISASSEMBLY (Page 9 to
24)”.
2. Insert the 5pin cable into the connector of the MAIN board
(CN501).
Note: Connect 5pin cable after removing the front panel block and DVD
mechanism deck referring to “3. DISASSEMBLY (Page 9 to 24)”.
– MAIN Board (Component Side) –
CN501
CN501
CN501
Insert the
5 pin cable of
RS-232C jig
5 pin cable of
RS-232C jig
3. The switch of RS232-JIG OVERALL ASSY is “L”.
H
moL
4. The communication software is start up.
5. Turn on the main power of unit.
5. Turn on the main power of unit.
The following log is displayed when starting while connected.
------ Test Mode 5 : HyperTerminal Start ------
Techwell Mode :
Data Read Format for Current Page: ‘r 5AB1’+[Enter]
Data Write Format for Current Page: ‘w C4D3 03’+[En-
ter]
Data Read Format for Current Page: ‘r 5AB1’+[Enter]
Data Write Format for Current Page: ‘w C4D3 03’+[En-
ter]
DAC Mode:0-vcom1_bias/1-vcom2_bias/2-vcom1_p/3-vcom2_p
Data Read Format : ‘drn’+ [Enter]
Data Write Format: ‘dwn 7D’+ [Enter]
Data Read Format : ‘drn’+ [Enter]
Data Write Format: ‘dwn 7D’+ [Enter]
Back Light Mode :
BCKL Read Format : ‘drb’+ [Enter]
BCKL Write Format: ‘dwb 7D’+ [Enter]
BCKL Read Format : ‘drb’+ [Enter]
BCKL Write Format: ‘dwb 7D’+ [Enter]
Flash Write
Save Data to Flash : ‘ds’+ [Enter]
Clear Flash Data : ‘dc’+ [Enter]
Save Data to Flash : ‘ds’+ [Enter]
Clear Flash Data : ‘dc’+ [Enter]
To Enter Test Mode : ‘ti’
To Exit Test Mode : ‘to’
To Exit Test Mode : ‘to’
To View Command ver: ‘svc’
=========== LINK OK ===========
XAV-701HD
26
2. FLICKER
ADJUSTMENT
Note 1: Perform adjustment of NTSC/PAL separately.
Procedure:
1. The setting of “1. SETTINGS” is completed.
2. Input the NTSC or PAL white 40% raster signal from AUX2
1. The setting of “1. SETTINGS” is completed.
2. Input the NTSC or PAL white 40% raster signal from AUX2
IN jack on the rear side of main unit.
3. In the state of source off, press the [4] → [5] → [4] (keeps
pressing) button on the remote commander.
The test mode 4 starts, and the “T4” is displayed on the moni-
tor.
tor.
Screen display
4. “dr0” is input by the communication software and “Enter” key
is pressed.
The following numerical value returns from the set.
(Following characters/values are example)
dr0
VCom1_Bias :
VCom1_Bias :
0x03E901A0
Vcom1_p
:
0x03E901D6
Vcom2_Bias :
0x04B00210
Vcom2_p
:
0x03E901D6
5. To change the adjusted value, “dw0 ####” is input by the com-
munication software and “Enter” key is pressed.
The following numerical value returns from the set.
• NTSC adjustment
dw0
03E9####
VCom1_Bias :
0x03E9####
Vcom1_p
:
0x03E901D6
Vcom2_Bias :
0x04B00210
Vcom2_p
:
0x03E901D6
• PAL adjustment
dw1
04B0####
VCom1_Bias :
0x03E901A0
Vcom1_p
:
0x03E901D6
Vcom2_Bias :
0x04B0####
Vcom2_p
:
0x03E901D6
####: Hexadecimal (“0000” to “FFFF”)
Adjust so that the fl icker becomes minimum in the sight by ad-
justing 10 steps of hexadecimal values at a time up and down.
justing 10 steps of hexadecimal values at a time up and down.
6. “ds” is input by the communication software and “Enter” key
is pressed and the numerical value is saved.
Note
2: Change is intelligible, when it changes into the home screen.
7. The “Reset” button is pressed and turn the power off.
Example of characteristic:
Flicker
Setting value (decimal)
bad
o
m
good
XAV-701HD
27
If any of the following parts was replaced, perform the “IOP
Check” as mentioned below.
Check” as mentioned below.
• Optical pick-up block (chassis (OP, ZA) complete assy)
• Complete SERVO board
• Complete SERVO board
Precaution
Use the following tools and measuring devices.
•
Use the following tools and measuring devices.
•
DVD test disc TDV-540C (Part No. J-2501-235-A)
•
CD test disc PATD-012 (Part No. 4-225-203-01)
• Digital
voltmeter
•
Accessory remote commander RM-X271
Note: This adjustment can be operated even if it is remote commander
which is not attached remote commander.
IOP CHECK
Connection:
Connection:
SERVO board
TP51 (IOPDVD), TP47 (IOPCD)
TP63 (D3.3V)
+
–
–
digital voltmeter
Procedure:
1. Check the IOP value of DVD and CD by label on the optical
1. Check the IOP value of DVD and CD by label on the optical
pick-up.
DVD IOP value
CD IOP value
Optical Pick-up Label:
"
2. Connect a digital voltmeter to TP51 (IOPDVD) and TP63
(D3.3V) on the SERVO board.
3. Playback the DVD test disc (TDV-540C), and make a note of
the value of digital voltmeter.
4. Divide the measured voltage value by 1, and convert it into
current value.
5. Check that the calculated value is within ±6 mA to the IOP
value given on the label.
6. Connect a digital voltmeter to TP47 (IOPCD) and TP63
(D3.3V) on the SERVO board.
7. Playback the CD test disc (PATD-012), and make a note of the
value of digital voltmeter.
8. Divide the measured voltage value by 1, and convert it into
current value.
9. Check that the calculated value is within ±6 mA to the IOP
value given on the label.
Check Location:
TP63
(D3.3V)
TP51
(IOPDVD)
TP47
(IOPCD)
– SERVO Board (Side B) –
SERVO SECTION
XAV-701HD
28
MEMO