DOWNLOAD Sony CDX-601 / CDX-636 Service Manual ↓ Size: 2.86 MB | Pages: 41 in PDF or view online for FREE

Model
CDX-601 CDX-636
Pages
41
Size
2.86 MB
Type
PDF
Document
Service Manual
Brand
Device
Car Audio
File
cdx-601-cdx-636.pdf
Date

Sony CDX-601 / CDX-636 Service Manual ▷ View online

12
OPERATION  CHECK
1
Confirm that the slider moves in the direction of the arrow 
C
 to move
down the chuck plate if the gear (LOAD 1) is rotated in the direction of the
arrow 
A
 or the chuck plate moves up and the slider moves in the direc-
tion of the arrow 
D
 if the gear is rotated in the direction of the arrow 
B
.
chuck plate
slider
gear (LOAD 1) ass’y
A
B
C
D
13
SECTION  5
MECHANICAL  ADJUSTMENT
• Elevator Height (Address) Adjustment
Note:
This adjustments is necessary when the system controller (IC201),
variable resistor (RV201), slider (R), slider (L), or chassis (ELV)
was replaced for any repair.
Connection:
Adjustment Method:
1. Connect this set to the master unit (e.g. MDX-C7970/C7970R),
load a disc magazine, and place the set vertically as shown
below.
2. Connect the regulated power supply to the master unit, and
turn the power on.
3. Press the DISC button on the master unit and select DISC 5.
4. At this time, if the elevator shaft does not position between
comb teeth A and B at addresses 5 and 6 as shown below,
adjust the following.
5. Press repeatedly the DISC + and – buttons on the master unit
so that the elevator shafts moves from address 6 to address 5,
or from 5 to 6. At this time, adjust RV201 on the main board
so that the elevator shaft positions smoothly between comb
teeth A and B.
6. Further, place the set horizontally and make same adjustment
as mentioned above.
7. After adjustment at addresses 5 to 6 is finished, check all op-
erations from addresses 1 to 10 with the set placed vertically
and horizontally respectively to confirm that the elevator shaft
positions in a range between comb teeth A to B.
power supply
GND
+
BUS cable
CDX-601/636
master unit
RV201
comb tooth at address 6
elevator shaft
comb tooth at address 6
comb tooth at address 5
OK
NG
elevator shaft
comb tooth at address 5
A
B
A
B
14
SECTION  6
ELECTRICAL  CHECK
Note:
Power supply voltage: DC14.4 V (more than 3 A).
• FOCUS BIAS CHECK
– RF BOARD –
 (Component Side)
Procedure:
1. Connect the oscilloscope to TP (RFO) and TP (VC) on the RF
board.
2. Put the set into play mode by loading the disc.
3. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note:
Clear RF signal waveform means that the shape “
” can be clearly distin-
guished at the center of the waveform.
• TRACKING OFFSET CHECK
– RF BOARD –
 (Component Side)
Procedure:
1. Connect the oscilloscope to TP (TE) and TP (VC) on the RF
board.
2. Put the set into play mode by loading the disc.
3. Press the . AMS > button, and check the traverse wave-
form*.
4. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0 V dc, and check this level.
* Traverse waveform: This is the tracking error wave form appears
when crossing the track.
oscilloscope
+
TP (VC)
TP 
(RFO)
IC101
RF signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.4 
±
 0.3 Vp-p
oscilloscope
+
TP (VC)
TP (TE)
IC101
A
0 V
A=B
traverse waveform
(100 track jump waveform)
VOLT/DIV : 500 mV
TIME/DIV : 2 ms
Center : 0 V
Traverse waveform
15
15
CDX-601/636
SECTION  7
DIAGRAMS
7-1.
BLOCK  DIAGRAM  – RF SERVO/DA CONVERTER Section –
M
M
6
7
VO4+
VO4–
VIN4+
VIN4–
10
11
VO2+
VO2–
MOTOR
DRIVE
MOTOR
DRIVE
COIL
DRIVE
12
13
VO1+
VO1–
VIN2+
VIN2–
42
43
FFDR
FRDR
38
39
31
32
22
21
5
4
VL0+
VL0–
FWD
REV
1
2
SFDR
SRDR
A
B
C
D
E
F
I-V AMP
PD
LD
DETECTOR
5
6
7
8
11
10
E I-V AMP
F I-V AMP
E
D
C
B
A
F
3
LD
RF
SUMMING
AMP
FOCUS
ERROR
AMP
RF EQ
AMP
16
RFO
14
FE
13
4
TE
TRACKING
ERROR
AMP
AUTOMATIC
POWER
CONTROL
Q101
APC LD
AMP
PD
AGC
22
21
20
LDON
HOLD SW
AGCCONT
APC PD
AMP
LDON
HOLD
AGC
RFDC
FE
TE
54 50 52 51
RFDC
FE
TE
61
60
59
ASYMMENTRY
CORRECTOR
RFAC
ASYI
ASYO
DIGITAL
PLL
EFM
DE-
MODULATOR
D/A
INTER-
FACE
63 66 65
64
FILO
CLTV
PCO
FILI
83
EMPH
FILTER
INTERNAL BUS
77
81
79
78
82
80
PCMD
LRCK
BCK
32k RAM
ERROR
CORRECTOR
54
55
56
LDON
HOLD
AGC
LDON
AGCHOLD
RF AGC
91 GFS
22
GFS
6
CDDATA
13
DATA
7
CDCLK
15
CLOK
5
CDXLT
77 SQSO
79 SQCK
82 SCOR
92 SCLK
90 FOK
XRST
14
XLAT
93 SENS
16
SENS
6
SQSO
7
SQCK
24
SCOR
17
SCLK
32
FOK
CPU
INTERFACE
SUBCODE
PROCESS
RFDC
FE
TE
SE
OP AMP
ANALOG SWITCH
A/D CONVERTER
MIRR
DFCT
FOK
DIGITAL SERVO
SIGNAL PROCESS
PWM GENERATOR
40
41
25
24
TEDR
TRDR
VIN1–B
18
8
9
VO3+
VO3–
VIN3+
VIN3–
DIGITAL
CLV
35
MDP
M
M103
(CHUCKING)
M102
(SPINDLE)
M101
(SLED)
TRACKING/FOCUS COIL DRIVE,
SLED/SPINDLE/CHUCKING
MOTOR DRIVE
IC201
MOTOR
DRIVE
COIL
DRIVE
SERVO AUTO
SEQUENCER
SERVO
INTERFACE
94
CH. F
71
CH. R
72
89
11
XRST
36
SSTP
LIMSW
SW3
(LIMIT)
65 LOAD1
SW1
(SAVE END DETECT)
66 LOAD2
SW2
(CHUCKING END DETECT)
ON : When the optical pick-up
        is inner position
ON : When completion of the disc
        save operation
ON : When completion of the disc
        chucking operation
84
SERIAL
IN
INTERFACE
DIGITAL FILTER,
NOISE SHAPER
97
90
96
91
AOUT2
AOUT1
BUFFER
AIN2
AIN1
92
95
LOUT
ROUT
GND-ISOLATION
IC401
EMPHI
PCMDI
LRCKI
BCKI
L
R
MUTING
Q410, 420
87
XTAO
86
XTAI
X130
16.9344MHz
TIMING
LOGIC
CLOCK
GENERATOR
4
AMUTE
MUTING
CONTROL
Q401, 402
SYSTEM CONTROLLER
IC201 (1/2)
DIGITAL SIGNAL PROCESSOR,
DIGITAL FILTER, D/A CONVERTER,
DIGITAL SERVO PROCESSOR
IC101
(TRACKING)
(FOCUS)
2-AXIS DEVICE
OPTICAL
PICK-UP BLOCK
(KSS-720A)
05
RF AMP,
FOCUS/TRACKING ERROR AMP
IC101
• SIGNAL PATH
: CD PLAY
LASER DIODE
PWM
&
INTEGRATOR
AUDIO OUT
L
R
CN901 (1/2)
Page of 41
Display

Click on the first or last page to see other CDX-601 / CDX-636 service manuals if exist.