Date

Sony ZS-M30 Service Manual ▷ View online

17
ZS-M30
TUNER BOARD
C27
C10
R5
JC3
C12
R28
C44
Q3
C45
C43
C51
C5
R7
R4
D2
C6
R2
R3
C7
R32
Q2
Q4
R6
C8
C46
C47
C4
L7
C54
C11
R13
C26
R14
C9
R30
D4
D8
D9
D5
R31
D6
D7
9
JW2
JW7
CT4
JW6
8
D3
L4
L2
JW10
L5
JW5
Q1
FL1
CT3
L3
CT2
JW4
JW3
JW1
+
Digital
JW4
(VT)
100K
voltmeter
SECTION 5
ELECTRICAL ADJUSTMENTS
RADIO BAND button : MW or LW
Volume : MIN
5-1.TUNER SECTION
AM Section
FM Section
RADIO BAND button : FM
Volume : MIN
Put the lead-wire
antenna close to
the supplisd MW/LW
loop  antenna.
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
telescopic
antenna
terminal
FM RF signal
generator
22.5kHz frequency deviation by
400Hz signal.
Output level : as low as possible
0.01 uF
Adjustment Location : Tuner board (See page 18)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust part
Frequency display
 L5
531kHz
Confirmation
1,611kHz
reading on digital
voltmeter.
Adjustment value: 1.0V
Standaed value: 0.7 to 1.3V
5.1  to  5.9V
MW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L 3
621kHz
CT2
1,404kHz
LW FREQUENCY COVERAGE ADJUSTMENT
Adjust part Frequency display
CT4
 279kHz
Adjustment value: 5.4 to 6.0V
Confirmation
153kHz
 0.4 to 1.1V
Frequency Coverage Adjustment
Connect Location :
reading on digital
voltmeter
LW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L 4
162kHz
CT3
261kHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust part Frequency display
Confirmation
 87.5kHz
1.4 to 2.4V
Confirmation
108kHz
2.7 to 3.7V
reading on digital
voltmeter
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
L6
10.7MHz
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.5MHz
CT1
108MHz
47K
level meter
set
LINE OUT
+
(SIDE B)
18
ZS-M30
L5 : MW Frequency
       Coverage Adjustment
CT4 : LW Frequency Coverage Adjustment
T1 : AM IF Adjustment
L6 : FM IF Adjustment
L3 : MW Tracking Adjustment
CT2 : MW Tracking Adjustment
CT1 : FM Tracking Adjustment
L4 : LW Tracking Adjustment
CT3 : LW Tracking Adjustment
L1 : FM Tracking Adjustment
[TUNER BOARD] 
(Component side)
Adjustment Location:
19
ZS-M30
5-2. MD SECTION
1. PARTS REPLACEMENT AND ADJUSTMENT
• Check and adjust the mechanism deck as follows.
The procedure changes according to the part replaced.
• Laser power check
• Focus bias check
• C PLAY check
• Self-recording/playback check
Parts Replacement and Repair
NG
Has the OWH been replaced?
NO
OK
NO
NO
NO
Has OP, IC603, IC502, or 
IC504 been replaced?
YES
YES
Initial setting of the adjustment value
Has OP or IC603 been replaced?
YES
IOP information recording
(IOP value labeled on OP)
Has IC603 or D501 
been replaced?
YES
Temperature compensation offset adjustment
• Laser power adjustment
• EF balance adjustment
• Focus bias adjustment
• Error rate adjustment
• Focus bias check
• Auto gain adjustment
Check the sled and spindle 
mechanisms. 
Other causes can be suspected.
• Abbreviation
OP
: Optical pick-up
OWH : Overwrite head
20
ZS-M30
2. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSION
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
3. PRECAUTIONS FOR USE OF OPTICAL PICK-UP
(KMS-260B)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connect-
ingthe connector, be careful not to remove the solder. Also take
adequate measures to prevent damage by static electricity. Handle
the flexible board with care as it breaks easily.
4. PRECAUTIONS FOR ADJUSTMENTS
1. When replacing the following parts, perform the adjustments
and checks with in the order shown in the following table.
2. Set the test mode when performing adjustments.
After completing the adjustments, release the test mode.
Perform the adjustments and checks in “group S” of the test
mode.
3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring device.
• Check Disc (MD) TDYS-1
(Part No. 4-963-646-01)
• Test Disc (MDW-74/AU-1) (Part No. 8-892-341-41)
• Laser power meter LPM-8001 (Part No. J-2501-046-A)
or MD Laser power meter 8010S (Part No. J-2501-145-A)
• Oscilloscope (Measure after performing CAL of prove)
• Digital voltmeter
• Thermometer
5. When observing several signals on the oscilloscope, etc., make
sure that VC and ground do not connect inside the oscilloscope.
(VC and ground will become short-circuited)
6. Using the above jig enables the waveform to be checked with-out
the need to solder.
(Refer to Service Note on page 3)
7. As the disc used will affect the adjustment results, make sure
that not dusts nor fingerprints are attached to it.
Laser Power Meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (Part No.
J-2501-145-A) instead of the conventional laser power meter is con-
venient.
It sharply reduces the time and trouble to set the laser power meter
sensor onto the objective lens of optical pick-up.
5. CREATING CONTINUOUSLY-RECORDED DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording
disc.
1. Insert a disc (blank disc) commercially available.
2. Turn the JOG dial to display “CREC MODE”.
3. Press the  YES/ENTER  button again to display “CREC MID”.
Display “CREC (0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the NO/CANCEL button and stop recording.
6. Press the  Z  (MD) button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment/check and MO error rate check.
Note:
• Be careful not to apply vibration during continuous recording.
flexible board
laser tap
pick- up
Optical pick-up flexible board
2.Temperature
compensation
offset adjustment
1. Recording of IOP
information
(Value written in
the pick-up)
3.Laser power
adjustment
4.EF balance
adjustment
5.Focus bias
adjustment
6.Error rate check
Optical
Pick-up
BD Board
IC603
D501
IC502, IC504
IC506
Page of 82