6. CHECK PRIOR TO REPAIRS
These checks are performed before replacing parts according to
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and Adjust-
ments”(See page 4).
6-1. Laser Power Check
Connection:
Checking Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the  m  but-ton
or  M  button to move the optical pick-up)
Connect the digital voltmeter to TPO 502 (I+3 V) and TP503 (IOP)
on the MD board.
2. Turm the JOG dial to display “LDPWR CHECK”.
3. Press the  YES/ENTER  button once to display “LD 0.9 mW $
 ”. Check that the reading of the laser power meter become
0.80 to 0.96 mW.
4. Press the  YES/ENTER  button once more to display “LD 7.0
mW $ 
 ”. Check that the reading the laser power meter and
digital voltmeter satisfy the specified value.
Specified Value:
Laser power meter reading : 6.8 - 7.2 mW
Digital voltmeter reading : Value on the optical pick-up label
±
 10 %
5. Press the  NO/CANCEL  button to display “LDPWR CHECK”
and stop the laser emission.
(The  NO/CANCEL  button is effective at all times to stop the
laser emission)
Note 1
: After step 4, each time the  YES/ENTER  button is pressed,
the display will be switched “LD 0.7 mW $ ”,
“LD 6.2 mW $ 
 ”,
and “LD WP 
 $ ”. Nothing needs to be performed
here.( 
= correction)
6-2. Focus Bias Check
Change the focus bias and check the focus tolerance amount.
Checking Procedure:
1. Load the test disc (MDW-74/AU-1).
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the  YES/ENTER  button twice to display “CPLAY  MID”.
4. Press the  NO/CANCEL  button when “C1 = 
 AD = 
 ”
is displayed.
5. Turn the JOG dial to display “FBIAS CHECK”.
6. Press the  YES/ENTER  button to display “ 
 / 
 c = 
 ”.
The first four digits indicate the C1 error rate, the two digits
after (( / )) indicate ADER, and the 2 digits after “c =” indicate
the focus bias value.
Check that the C1 error is below 50 and ADER is below 2.
7. Press the  YES/ENTER  button to display “ 
 / 
 b = 
 ”.
Check that the C1 error is about 200 and ADER is below 2.
8. Press the  YES/ENTER  button to display “ 
 / 
 a = 
 ”.
Check that the C1 error is about 200 and ADER is below 2.
9. Press the  NO/CANCEL  button, then press the  Z  (MD)
button and take out the test disc.
6-3. C PLAY Check
MO Error Rate Check
Checking Procedure:
1. Load the test disc (MDW-74/AU-1).
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the  YES/ENTER  button to display “CPLAY MID”.
4. The display changes to “C1 = 
 AD = 
 ”.
5. If the C1 error rate is below 80, check that ADER is below 2.
6. Press the  NO/CANCEL  button to stop playback, then press
the  Z  (MD) button and take out the test disc.
CD Error Rate Check
Checking Procedure:
1. Load the check disc (MD) TDYS-1.
2. Turn the JOG dial  to display “CPLAY MODE”.
3. Press the  YES/ENTER  button twice to display “CPLAY  MID”.
4. The display changes to “C1 = 
 AD = 
 ”.
5. Check that the C1 error rate is below 50.
6. Press the  NO/CANCEL  button to stop playback, then press
the  Z  (MD) button and take out the check disc.
laser
power meter
Optical pick-up
objective lens
 
 
 
 
R622
C508
C521
C512
L503
C502
R511
C518
C511
C505
R505
R510
Q503
R508
R513
R509
R517
C519
C517
C520 C522
R519
R516
R512
C506
R504
R503
Q506
Q507
Q505
Q504
R518
Q502
R515
IC502
R5
2
L501
L506
C611
R633
Q501
R514
R502
C607
 
 
 
 
 
TP503
(IOP)
TP502
(I+3V)
(TE)
1
36
25
24
13
15
20
37
48
45
40
30
35
5
1012
TP502 (I+3V)
TP503 (IOP)
MD BOARD (SIDE B)
digital voltmeter
KMS260B
27X40
B0825
lOP=82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/3.3 (
)
(Optical pick-up label)
22
ZS-M30
7. Turn the JOG dial to display “LDPWR CHECK”.
8. Press the  YES/ENTER  button once to display “LD 0.9mW
 ”. Check that the reading of the laser power meter become
0.85 to 0.91 mW.
9. Press the  YES/ENTER  button once more to display “LD 7.0
mW $ 
 ”. Check that the reading the laser power meter and
digital voltmeter satisfy the specified value.
Note down the digital voltmeter reading value.
6-4. Self-Recording/playback Check
Prepare a continuous recording disc using the unit to be repaired
and check the error rate.
Checking Procedure:
1. Load a recordable disc (blank disc).
2. Turn the JOG dial to display “CREC MODE”.
3. Press the  YES/ENTER  button to display “CREC MID”.
4. When recording starts, lights up “  REC  ” and display “CREC
(@@@@)” (@@@@ is the address).
5. About 1 minute later, press the  NO/CANCEL  button to
stop continuous recording.
6. Turn the JOG dial to display “CPLAY MODE”.
7. Press the  YES/ENTER  button to display “CPLAY MID”.
8. “C1 = 
 AD = 
 ” will be displayed.
9. Check that the C1 error becomes below 80 and the ADER be-
low 2.
10.Press the  NO/CANCEL  button to stop play back, then press
the  Z  (MD) button and take out the disc.
Note: After the TEST MODE is entered, insert the disc.
7. TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 
°
C reference data.
Note:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 
°
C to
28 
°
C.
Perform it immediately after the power is turned on when the
internal temperature of the unit is the same as the ambient tem
perature of 22 
°
C to 28 
°
C.
3. When D501 has been replaced, perform this adjustment after
the tem-perature of this part has become the ambient tempera
ture.
Adjusting Procedure:
1. Turn the JOG dial to display “TEMP ADJUST”.
2. Press the  YES/ENTER  button to select the “TEMP ADJUST”
mode.
3. “TEMP = 
 ” and the current temperature data will be displayed.
4. To save the data, press the  YES/ENTER  button.
When not saving the data, press the NO/CANCEL button.
5. When the  YES/ENTER  button is pressed, “TEMP = SAVE”
will be displayed and turned back to “TEMP ADJUST” display
then. When the  NO/CANCEL  button is pressed, “TEMP
ADJUST” will be displayed immediately.
Specified Value:
The “TEMP = 
 ” should be within “E0 - EF”, “F0 - FF”, “00 -
0F”,“10 - 1F” and “20 - 2F”.
Adjusting Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the  m  but-ton
or  M button to move the optical pick-up)
Connect the digital voltmeter to TP502  (I+3  V) and TP503
(IOP) on the MD board.
2. Turn the JOG dial to display “LDPWR ADJUST”.
(Laser power: For adjustment)
3. Press the  YES/ENTER  button once to display “LD 0.9 mW
 ”.
4. Turn the JOG dial so that the reading of the laser power meter
becomes 0.85 to 0.91 mW. Press the  YES/ENTER  button after
setting the range knob of the laser power meter, and save the
adjustment results. (“LD SAVE $ 
 ” will be displayed for a
moment)
5. Then “LD 7.0 mW $ 
 ” will be displayed.
6. Turn the JOG dial and adjust so that the reading on the laser
power meter is 6.9 to 7.1 mW. Press the  YES/ENTER  button to
save the setting.
Note: Do not perform the emission with 7.0 mW more than 15 sec
onds continuously.
8. LASER POWER ADJUSTMENT
Connection:
laser
power meter
Optical pick-up
objective lens
 
 
 
 
R622
C508
C521
C512
L503
C502
R511
C518
C511
C505
R505
R510
Q503
R508
R513
R509
R517
C519
C517
C520 C522
R519
R516
R512
C506
R504
R503
Q506
Q507
Q505
Q504
R518
Q502
R515
IC502
R5
2
L501
L506
C611
R633
Q501
R514
R502
C607
 
 
 
 
 
TP503
(IOP)
TP502
(I+3V)
(TE)
1
36
25
24
13
15
20
37
48
45
40
30
35
5
1012
TP502 (I+3V)
TP503 (IOP)
MD BOARD (SIDE B)
digital voltmeter
23
ZS-M30
10. Press the  NO/CANCEL  button to display “LDPWR
 CHECK” and stop the laser emission.
(The  NO/CANCEL  button is effective at all times to stop
the laser emission)
Note 1: After step 9, each time the 
 YES/ENTER
  button is pressed, the
display will be switched “LD 0.7 mW $ 
 ”, “LD 6.2 mW $ 
 ”,
and “LD WP 
 $ 
 ”. Nothing needs to be performed here.
 = correction)
KMS260B
27X40
B0825
lOP=82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/3.3 (
)
(Optical pick-up label)
9. EF BALANCE ADJUSTMENT
Adjusting Procedure:
1. Connect an oscilloscope to TP504 (TE) and TP506 (VC) on
the MD board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the  M  button to move the optical pick-up outside the
pit.
4. Turn the JOG dial to display “EFBAL ADJUST”.
5. Press the  YES/ENTER  button to display “EFB = MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Turn the JOG dial so that the waveform of the oscilloscope be
comes the specified value.
(When the JOG dial is turned, the 
 of “EFB = 
 ”  changes
and the waveform changes ) In this adjust-ment, wave form var
ies at intervals of approx. 2 %. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Read power traverse adjustment)
7. Press the  YES/ENTER  button and save the result of adjust-
ment to the non-volatile memory. (“EFB = SAVE” will be
displayed for a moment. Then “EFB = MO-W” will be dis-
played)
8. Turn the JOG dial so that the waveform of the oscilloscope be
comes the specified value.
(When the JOG dial is turned, the 
 of “EFB- 
 ” changes and
the waveform changes) In this adjustment, waveform varies at
intervals of approx. 2%. Adjust the waveform so that the speci-
fied value is satisfied as much as possible.
(Write power traverse adjustment)
Note 1:
 Data will be erased during MO reading if a recorded
disc is used in this adjustment.
Note 2:
 If the traverse waveform is not clear, connect the
oscilloscope as shown in the following figure so that
it can be seen more clearly.
 
 
 
 
 
 
 
 
C521
C526
L509
5
17
C519
C520 C522
R519
R518
R533
R531
R535
IC502
R524
R532
R525
R540
R542
R5
4
C546
R538
C550
 
 
 
 
 
 
 
 
 
TP505
(RF)
TP506
(VC)
TP504
(TE)
36
25
24
20
37
40
30
35
MD BOARD
 (SIDE B)
oscilloscope
(DC range)
Connection:
 
 
 
 
 
 
 
 
C521
C526
L509
5
17
C519
C520 C522
R519
R518
R533
R531
R535
IC502
R524
R532
R525
R540
R542
R5
4
C546
R538
C550
 
 
 
 
 
 
 
 
 
TP505
(RF)
TP506
(VC)
TP504
(TE)
36
25
24
20
37
40
30
35
[MD BOARD]
 
(SIDE B)
oscilloscope
(DC range)
A
B
VC
Specification : A = B
Traverse Waveform
A
B
VC
Specification : A = B
Traverse Waveform
Specified Value:
Laser power meter reading : 7.0 
±
 0.2 mW
Digital voltmeter reading : Value on the optical pick-up label
±
 10%
24
ZS-M30
9.  Press the  YES/ENTER  button, and save the adjustment re-
 sults in the non-volatile memory. (“EFB = 
 SAVE” will be
displayed for a moment)
10. “EFB = 
 MO-P” will be displayed.
 The optical pick-up moves to the pit area automatically and
 servo is imposed.
11. Turn the JOG dial until the waveform of the oscilloscope moves
 closer to the specified value.
 In this adjustment, waveform varies at intervals of approx. 2%.
 Adjust the waveform so that the specified value is satisfied as
 much as possible.
12. Press the  YES/ENTER  button, and save the adjustment re-
sults in the non-volatile memory. (“EFB = 
 SAVE” will be
displayed for a moment)
Next “EFBAL ADJUST” is displayed. The disc stops rotating
automatically.
13. Press the  Z  (MD) button and take out the disc.
14. Load the check disc (MD) TDYS-1.
15. Press the  YES/ENTER  button to display “EFB =  
 CD”.
Servo is imposed automatically.
16. Turn the JOG dial so that the waveform of the oscilloscope
moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx.
2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
17. Press the  YES/ENTER  button, display “EFB = 
 SAVE” for
a moment and save the adjustment results in the non-volatile
memory.
Next “EFBAL ADJUST” will be displayed.
18. Press the  Z  (MD) button and take out the disc.
10. FOCUS BIAS ADJUSTMENT
Adjusting Procedure:
1. Load the continuously-recorded disc.
 (Refer to “5. CREATING CONTINUOUSLY-RECORDED
  DISC”)
2. Turn the JOG dial to display “CPLAY MODE”.
3. Press the  YES/ENTER  button to display “CPLAY MID”.
4. Press the  NO/CANCEL  button when “C1 = 
 AD = 
 ”
is displayed.
5. Turn the JOG dial to display “FBIAS ADJUST”.
6. Press the  YES/ENTER  button to display “ 
 / a = 
 ”.
The first four digits indicate the C1 error rate, the two digits
after “  /  ” indicate ADER, and the 2 digits after “a =” indicate
the focus bias value.
7. Turn the JOG dial clockwise and find the focus bias value at
which the C1 error rate becomes about 200 (Refer to Note 2).
8. Press the  YES/ENTER  button to display “ 
 / b = 
 ”.
9. Turn the JOG dial counterclockwise and find the focus bias
value at which the C1 error rate becomes about 200.
10. Press the  YES/ENTER  button to display “ 
 / 
 c = ”.
11. Check that the C1 error rate is below 50 and ADER is 00.
Then press the  YES/ENTER  button.
12. If the “( 
 )” in “ 
 - 
 - 
 ( 
 )” is above 20, press the
YES/ENTER button.
If below 20, press the  NO/CANCEL  button and repeat the
adjustment from step 2.
13. Press the  Z  (MD) button and take out the disc.
Note 1: The relation between the C1 error and focus bias is as shown in
the following figure. Find points A and B in the following figure
using the above adjustment. The focal point position C is auto-
matically calculated form points A and B.
Note 2: As the C1 error rate changes, perform the adjustment using the
average value.
11. ERROR RATE CHECK
11-1. CD Error Rate Check
Checking Procedure:
1. Load the check disc (MD) TDYS-1.
2. Turn the JOG dial and display “CPLAY MODE”.
3. Press the  YES/ENTER  button twice and display “CPLAY
MID”.
4. The display changes to “C1 = 
 AD = 
 ”.
5. Check that the C1 error rate is below 20.
6. Press the  NO/CANCEL  button to stop playback, then press
the  Z  (MD) button and take out the check disc.
11-2. MO Error Rate Check
Checking Procedure:
1. Load the continuously-recorded disc. (Refer to “5. CREATING
CONTINUOUSLY-RECORDED DISC”)
2.  Turn the JOG dial to display “CPLAY MODE”.
3.  Press the  YES/ENTER  button to display “CPLAY MID”.
4.  The display changes to “C1 = 
 AD = 
 ”.
5.  If the C1 error rate is below 50, check that ADER is 00.
6.  Press the  NO/CANCEL button to stop playback, then
press the  Z  (MD) button and take out the test disc.
A
B
VC
Specification : A = B
Traverse Waveform
A
B
VC
Specification : A = B
Traverse Waveform
B
C
A
C1 error
Focus bias value
(F.BIAS)