DOWNLOAD Sony STR-KIV300 Service Manual ↓ Size: 5.65 MB | Pages: 80 in PDF or view online for FREE

Model
STR-KIV300
Pages
80
Size
5.65 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
str-kiv300.pdf
Date

Sony STR-KIV300 Service Manual ▷ View online

STR-KIV300
61
Pin No.
Pin Name
I/O
Description
E7
DML
I
Input Data Mask: DM is an input mask signal for write data. Input data is masked when DM 
is sampled HIGH coincident with that input data during a Write access. DM is sampled on 
both adges of DQS. For x8 device, the function of DM or TDQS/ TDQS is enabled by Mode 
Register A11 setting in MR1.
E8
VSSQ
-
DQ Ground
E9
VDDQ
-
DQ Power Supply: 1.5V +/-0.075V
F1
VDDQ
-
DQ Power Supply: 1.5V +/-0.075V
F2
DQL2
I/O
Data Input/output: Bi-directional data bus.
F3
DQSL
I/O
Data Strobe: Output with read data, input with write data. Edge-aligned with read data, cen-
tered in write data. For the x16, DQSL: corresponds to the data on DQL0-DQL7; DQSU corre-
sponds to the data on DQU0-DQU7. The data strobe DQS, DQSL and DQSU are paired with 
differential signals DQS, DQSL and DQSU, respectively, to provide differential pair signaling 
to the system during reads and writes. DDR3 SDRAM supports differential data strobe only 
and does not support single-ended.
F4
NO_USE
-
Not used
F5
NO_USE
-
Not used
F6
NO_USE
-
Not used
F7
DQL1
I/O
Data Input/output: Bi-directional data bus.
F8
DQL3
I/O
Data Input/output: Bi-directional data bus.
F9
VSSQ
-
DQ Ground
G1
VSSQ
-
DQ Ground
G2
DQL6
I/O
Data Input/output: Bi-directional data bus.
G3
DQSL
I/O
Data Strobe: Output with read data, input with write data. Edge-aligned with read data, cen-
tered in write data. For the x16, DQSL: corresponds to the data on DQL0-DQL7; DQSU corre-
sponds to the data on DQU0-DQU7. The data strobe DQS, DQSL and DQSU are paired with 
differential signals DQS, DQSL and DQSU, respectively, to provide differential pair signaling 
to the system during reads and writes. DDR3 SDRAM supports differential data strobe only 
and does not support single-ended.
G4
NO_USE
-
Not used
G5
NO_USE
-
Not used
G6
NO_USE
-
Not used
G7
VDD
-
Power Supply: 1.5V +/-0.075
G8
VSS
-
Ground
G9
VSSQ
-
DQ Ground
H1
VREFDQ
-
Reference voltage for DQ
H2
VDDQ
-
DQ Power Supply: 1.5V +/-0.075V
H3
DQL4
I/O
Data Input/output: Bi-directional data bus.
H4
NO_USE
-
Not used
H5
NO_USE
-
Not used
H6
NO_USE
-
Not used
H7
DQL7
I/O
Data Input/output: Bi-directional data bus.
H8
DQL5
I/O
Data Input/output: Bi-directional data bus.
H9
VDDQ
-
DQ Power Supply: 1.5V +/-0.075V
J1
NC
-
No Connect: No internal eletrical connection is present.
J2
VSS
-
Ground
J3
RAS
I
Command Input: RAS (along with CS) defi ne the command being entered.
J4
NO_USE
-
Not used
J5
NO_USE
-
Not used
J6
NO_USE
-
Not used
J7
CK
I
Clock: CK is differential clock input. All address and control input signals are sampled on the 
crossing of the positive adge of CK. Output (read) data is referenced to the crossing of CK.
J8
VSS
-
Ground
J9
NC
-
No Connect: No internal eletrical connection is present.
K1
ODT
I
On Die Termination: ODT (registered HIGH) enables termination resistance internal to the 
DDR3 SDRAM. When enabled, ODT is only applied to each DQ, DQS, DQS and DM/TDQS, 
NU/TDQS (When TDQS is enabled via Mode Register A11=1 in MR1) signal for x8 confi gura-
tions. The ODT pin will be ignored if the Mode Register (MR1) is programmed to disable ODT.
STR-KIV300
62
Pin No.
Pin Name
I/O
Description
K2
VDD
-
Power Supply: 1.5V +/-0.075
K3
CAS
I
Command Input: CAS (along with CS) defi ne the command being entered.
K4
NO_USE
-
Not used
K5
NO_USE
-
Not used
K6
NO_USE
-
Not used
K7
CK
I
Clock: CK is differential clock input. All address and control input signals are sampled on the 
crossing of the negative adge of CK. Output (read) data is referenced to the crossing of CK.
K8
VDD
-
Power Supply: 1.5V +/-0.075
K9
CKE
I
Clock Enable: CKE HIGH activates, and CKE LOW deactivates, internal clock signal and de-
vice input buffers and output drivers. Talking CKE LOW provides Precharge Power-Down and 
Self Refresh operation (all banks idle), or Active Power-Down (Row Active in any bank). CKE 
is asynchronous for self refresh exit. After V
REFCA
 has become stable during the power on and 
initialization sequence, it must be maintained during all operations (including Self-Refresh). 
CKE must be maintained high throuhthout read and write accesses. Input buffers, excluding 
CK, CK, ODT and CKE are disabled during power-down. Input buffers, excluding CKE, are 
disabled during Self-Refresh.
L1
NC
-
No Connect: No internal eletrical connection is present.
L2
CS
I
Chip Select: All commands are masked when CS is registered HIGH. CS provides for external 
Rank selection on system with multiple Ranks. CS is considered part of the command code.
L3
WE
I
Command Input: WE (along with CS) defi ne the command being entered.
L4
NO_USE
-
Not used
L5
NO_USE
-
Not used
L6
NO_USE
-
Not used
L7
A10
I
Address inputs: Provided the row address for active commands and the column address 
for Read/Write commands to select one location out of the memory array in the respective 
bank. The address inputs also provide the op-code during Mode Register Set commands.
Autoprecharge: A10 is sampled during Read/Write commands to deter-
mine whether Autoprecharge should be performed to the accessed bank af-
ter the Read/Write operation. (HIGH: Autoprecharge; LOW: No Autoprecharge)
A10 is sampled during a Precharge command to determin the Percharge applies to one bank 
(A10 LOW) or all banks (A10 HIGH). If only one bank is to be precharged, the bank is selected 
by bank adresses.
L8
ZQ
-
Reference Pin for ZQ calibration
L9
NC
-
No Connect: No internal eletrical connection is present.
M1
VSS
-
Ground
M2
BA0
I
Bank Adress Inputs: BA0 defi ne to which bank an Active, Read, Write or Precharge command 
is being applied. Bank address also determines if the mode register or extended mode register 
is to be accessed during a MRS cycle.
M3
BA2
I
Bank Adress Inputs: BA2 defi ne to which bank an Active, Read, Write or Precharge command 
is being applied. Bank address also determines if the mode register or extended mode register 
is to be accessed during a MRS cycle.
M4
NO_USE
-
Not used
M5
NO_USE
-
Not used
M6
NO_USE
-
Not used
M7
NC
-
No Connect: No internal eletrical connection is present.
M8
VREFCA
-
Reference voltage for CA
M9
VSS
-
Ground
N1
VDD
-
Power Supply: 1.5V +/-0.075
N2
A3
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
N3
A0
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
N4
NO_USE
-
Not used
N5
NO_USE
-
Not used
N6
NO_USE
-
Not used
STR-KIV300
63
Pin No.
Pin Name
I/O
Description
N7
A12
I
Address inputs: Provided the row address for active commands and the column address 
for Read/Write commands to select one location out of the memory array in the respective 
bank. The address inputs also provide the op-code during Mode Register Set commands.
Burst Chop: A12 is sampled during Read and Write commands to determine if burst chop (on-
the-fl y) will be performed. (HIGH: no burst chop, LOW: burst chopped).
N8
BA1
I
Bank Adress Inputs: BA1 defi ne to which bank an Active, Read, Write or Precharge command 
is being applied. Bank address also determines if the mode register or extended mode register 
is to be accessed during a MRS cycle.
N9
VDD
-
Power Supply: 1.5V +/-0.075
P1
VSS
-
Ground
P2
A5
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
P3
A2
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
P4
NO_USE
-
Not used
P5
NO_USE
-
Not used
P6
NO_USE
-
Not used
P7
A1
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
P8
A4
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
P9
VSS
-
Ground
R1
VDD
-
Power Supply: 1.5V +/-0.075
R2
A7
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
R3
A9
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
R4
NO_USE
-
Not used
R5
NO_USE
-
Not used
R6
NO_USE
-
Not used
R7
A11
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
R8
A6
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
R9
VDD
-
Power Supply: 1.5V +/-0.075
T1
VSS
-
Ground
T2
RESET
I
Active Low Asynchronous Reset: Reset is active when RESET is LOW, and inactive when 
RESET is HIGH. RESET must be HIGH during normal operation. RESET is CMOS rail to rail 
signal with DC high and low at 80% and 20% of VDD, example, 1.20V for DC high and 0.30V 
for DC low.
T3
A13
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
T4
NO_USE
-
Not used
T5
NO_USE
-
Not used
T6
NO_USE
-
Not used
T7
A14
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
STR-KIV300
64
Pin No.
Pin Name
I/O
Description
T8
A8
I
Address inputs: Provided the row address for active commands and the column address for 
Read/Write commands to select one location out of the memory array in the respective bank. 
The address inputs also provide the op-code during Mode Register Set commands.
T9
VSS
-
Ground
Page of 80
Display

Click on the first or last page to see other STR-KIV300 service manuals if exist.