3-9. LOADING  BOARD,  MOTOR (L)  ASSY (LOADING)  (M151)
2
3
tray (66)
1
two claws
4
gear (LD)
5
belt (LD)
6
two screws
(B2.6 
× 
4)
9
motor (L) assy (loading)
(M151)
8
LOADING board
7
Remove two solders.
guide
tape (clamp)
tape (clamp)
cushion
3-10. HARNESS  SETTING
10
SCD-XA1200ES
SECTION  4
TEST  MODE
PANEL  CHECK  MODE
Procedure:
1. While shorting the land A of the figure below and ground,
and pressing the  
.
 AMS 
>
  knob, press the [POWER] button
to turn the power on.
2. When enter the panel check mode, fluorescent indicator tube
and LEDs all light up for 5 seconds. Then, the pattern is each
grid is displayed, and it is displayed at the end as “SIRCS
CHECK”.
3. Press the  
H
  key of remote commander to enter the key check
mode and display “KEY CHECK 12”.
(*1)
4. Each button is pressed or each land of the figure below is
shorted, the display number of  “KEY CHECK” decreases.
5. All operations is performed, release the key check mode and
enter the jog check mode, then display “JOG CHECK”.
6. Turn the  
.
 AMS 
>
  knob clockwise until “15” is displayed
on the calendar area.
7. Turn the  
.
 AMS 
>
  knob counterclockwise until “1” is
black out on the calendar area and jog check is OK and display
“TEST-END”.
8. Press the [POWER] button to turn the power off and release
the panel check mode.
*1) If press the  
x
  key, it displays “KEY CHECK 19”. However,
this mode is for the model with changer. Therefore, it does not
become OK unless 19 buttons are pressed. If entered to this
mode by mistake, press the [POWER] button to turn the power
off and repeat operation form step 1.
Land Location:
R843
R844
R842
R845
S843
S842
– KEY-R Board (Conductor Side) –
Land 
A
Land 
B
R863
R864
R861
S863
S861
Land 
C
– KEY-L Board (Conductor Side) –
11
SCD-XA1200ES
TEST  MODE
1. Entering The Test  Mode
While press the [MENU] button and  
.
 AMS 
>
  knob, press the
[POWER] button to turn the power on and enter the test mode and
display “DIAG MODE”.
2. Operating The Test  Mode
Procedure:
1. Turn the  
.
 AMS 
>
  knob to select the command number
(hexadecimal number) (refer to the following table for
command number).
2. Press the  
.
 AMS 
>
  knob to execute the selected command
item.
3. Releasing The Test  Mode
Press the [POWER] button to turn the power off.
4. The Commands in Test Mode
Command No.
Command name
Item
12
LD ON/OFF
Turn on/off the laser diode
13
SPIN ON/OFF
Turn on/off the spindle motor
14
FSRV ON/OFF
Turn on/off the focus servo
15
TSRV ON/OFF
Turn on/off the tracking servo
16
CLV ON/OFF
Turn on/off the spindle CLV servo, when both focus servo and tracking servo are on
17
SSRV ON/OFF
Turn on/off the spindle CLV servo, when all servo of focus servo, tracking servo and spindle servo are on
18
ALL SRV ON
Turn on all servo
19
ALL SRV OFF
Turn off all servo
1A
DISC STOP
Stop the disc rotation (useful as overdrived)
24
ADJ FCSBIAS
Automatically adjust the focus bias (*2)
27
FOCUS AGC
Automatically adjust the focus servo gain (*2)
31
PI/FE OFSET
Automatically adjust the offset signal of PI, PE and TE (*2)
45
TRACKING AGC
Automatically adjust the focus servo gain (*2)
61
DISC DETECT
Judge the disc type (when SA-CD, “SL” or “DL” is displayed)
7C
FJUMP TEST
Focus jump test mode
81
SYSTEM VERSION
Display the version of system microcomputer for 2 seconds
82
I/F VERSION
Display the version of IF microcomputer for 2 seconds
8D
SETUP
initialize (for AEP model)
8F
SETUP
initialize (for except AEP model)
Error rate display (to stop, press the  
x
  button)
92
ERR CHECK
for CD display “92  C1 C2 FF”
for SA-CD display “92  PI1 PO PI2”
93
WATER MARK
WaterMark display
display “93      xxxx” (“xxxx” is value of pspamp)
9D
PLAY&RFD ON
Measuring the jitter (to stop, press the  
x
  button)
display: “9D  xx FF FF” (“xx” is measuring value of jitter)
B0
FFFF
The electrical adjustment value clear (*3)
B1
(Change value)
Writing of the electrical adjustment value (*3)
B2
(Change value)
Confirm of the electrical adjustment value (*3)
*2) Not used in servicing
*3) Only softwere version of the system 1.24 or later
12
SCD-XA1200ES
3. OPTICAL  SENSITIVITY  CHECK
Connection:
Use the following hybrid disc on this check.
HLXA-509 (Part No. J-6090-090-A) or Super Audio CD Hybrid
Disc (Market Disc)
Procedure:
1. Connect the oscilloscope to pin wj of CN702 on the MAIN
board.
2. Insert the test disc (HLXA-509) or Super Audio CD hybrid
disc (market disc).
3. Confirm the waveform at that time because the disc is
distinguished at chucking moment.
4. Confirm 
∆t of the shape of waves is a specified value.
Specified Value: 7.5 ms to 9.7 ms
(software version of the system 1.24 or later)
6.9 ms to 9.7 ms
(software version of the system less than 1.24)
5. When step 4 is NG, R892 and R893 on the MAIN board are
changed and the waveform is measured again.
In case of the specified value or more: Change R892 and R893
to 110 k
Ω (part No. 1-218-896-11).
In case of the specified value or less: Change R892 and R893
to 130 k
Ω (part No. 1-218-898-11).
6. Eject the disc and turn the power off.
Adjust it as follows after the optical traverse unit (DBU-3), WALTZ-
RF board, MAIN board, master controller (IC705), SA-CD/CD
decoder (IC706) and EEPROM (IC702) are replaced.
Adjustments Frow
1. ROM VERSION CHECK
2. U-CON CHECK
3. OPTICAL SENSITIVITY CHECK
4. MODE SETTING FOR SHIPPING (perform this mode only
when EEPROM (IC702) is replaced)
1. ROM  VERSION  CHECK
Software version of the system is confirmed.
Procedure:
1. While pressing the [MENU] button and  
.
 AMS 
>
  jog press
the [POWER] button to turn the power on and enter the test
mode and display “DIAG MODE”.
2.
.
 AMS 
>
  jog is turned and “81” is selected.
3.
.
 AMS 
>
  jog is pressed and software version of the system
is displayed.
4. “SYS VER 
*.**” is displayed.
5.
.
 AMS 
>
  jog is turned and “82” is selected.
6.
.
 AMS 
>
  jog is pressed and I/F version is displayed.
7. “I/F VER 
*.**” is displayed.
2. U-CON  CHECK (only software version of the
system 1.24 or later)
When the software version of the system 1.24 or later, this checking
must be performed before “3. OPTICAL SENSITIVITY CHECK”
and “4. MODE SETTING FOR SHIPPING”.
Procedure:
1. While pressing the [MENU] button and  
l
 AMS 
L
  jog press
the [POWER] button to turn the power on and enter the test
mode and display “DIAG MODE”.
2. Insert the test disc (SATD-S5). (Part No. : J-2501-215-A)
3.
.
 AMS 
>
  jog is turned and “B0” is selected.
4.
.
 AMS 
>
  jog is pressed and confirm “FFFF” is displayed.
5.
.
 AMS 
>
  jog is turned and “B1” is selected. “
6.
.
 AMS 
>
  jog is pressed and confirm “
−9” is displayed.
Then the value is changed and the value of four digits is
displayed after “
−0”.
7.
.
 AMS 
>
  jog is turned and “B2” is selected.
8.
.
  AMS 
>
    jog is pressed and confirm the value of four
digits is displayed.At this time, confirm the value displayed at
the end is a specified value.
Specified Value: 08D0 to 04D0
9. Eject the test disc and press the [POWER] button to turn the
power off.
software version of the
system 1.24 or later
software version of the
system less than 1.24
+
MAIN board
CN702 pin 
wj
oscilloscope
Waveform
t
SECTION  5
ELECTRICAL  ADJUSTMENTS
Ver. 1.1
Page of 56
Display