66
SCD-C555ES
(2) CD (Use the test disc PATD-012 or YEDS-18)
Note:
Measured values in check items are typical ones.
Check items
Specified value
LOAD IN TIME (msec)
:
Not displayed in this set.
SPIN UP TIME (msec)
: 1372
2500 msec or less
RF/VC/FE/TE AVRG (ORG)
: 98, C, 1D6, 4
RF: 80-9B, VC: 1F1-10, FE: 1B8-42, TE: 1BB-5C
RF/VC/FE/TE AVRG (ADJ)
: 9F, A, 1FF, 4
RF: 98-A5, VC: 1F1-10, FE: 1F1-10, TE: 1F1-10
PI/TRVS PP(ORG/ADJ)
: 81, 131, 95, 92
PI ORG: 70-89,  PI ADJ: 122-135, TRVS ORG: 70-120, TRVS-ADJ: 70-120
PIOR/CCR/TRCR
: 1A, 11, 1F
No specified value given
FOCUS/TRK GAIN
: 2E, 2D
FOCUS: 20-40, TRK: 20-40
FBIAS/TRVSC/TRCR2/CFR
: 0, 10, 5, A0
F.BIAS: 1E0-30,  TRVSC: 1F0-10    TRCR2, CFR: no specified value given
MIN JITTER AT F.BIAS
: 94
200 or less
READ TOC TIME (msec)
: 1410
2500 msec or less
1/3 SEEK TIME
F) AVE/MIN/MAX (msec)
: 824, 804, 850
AVE: 1000 msec or less, MAX: 1200 msec or less
R) AVE/MIN/MAX (msec)
: 850, 833, 860
AVE: 1000 msec or less, MAX: 1200 msec or less
1/MAX SEEK TIME
F) AVE/MIN/MAX (msec)
: 2086, 1999, 2151
AVE: 2300 msec or less, MAX: 2500 msec or less
R) AVE/MIN/MAX (msec)
: 1805, 1793, 1835
AVE: 2300 msec or less, MAX: 2500 msec or less
ERROR RATE
C1 MAX/AVE
: 3, 0
C1  MAX: 15 or less
C2 MAX/AVE
: 0, 0
C2  MAX: 0
HENSHIN RYOU (1/10um)
: 89
800 or less (100 um or less)
SPIN DOWN TIME (msec)
: 1272
2000 msec or less
LOAD OUT TIME (msec)
:
Not displayed in this set.
Note:
RF, VC, FE, TE, FBIAS and TRVSC measured values are hexadecimal data with positive and negative signs. When comparing the measured
value with the specified value, refer to the following.
Hexadecimal (hex) display 9 bit data
FF
011111111 (+255) 
FE
011111110 (+254) 
(+) Side
(-) Side
MAX
01
000000001 (+1) 
00
000000000 (0) 
1FF
111111111 (-1) 
101
100000001 (-255) 
100
100000000 (-256) 
Hexadecimal (hex) display 8 bit data
7F
01111111 (+127) 
7E
01111110 (+126) 
01
00000001 (+1) 
00
00000000 (0) 
02
00000010 (+2) 
FF
11111111 (-1) 
FE
11111110 (-2) 
81
10000001 (-127) 
80
10000000 (-128) 
MIN
0
67
SCD-C555ES
6-3. SACD (DL) DISC OPERATION CHECK
(• Perform as necessary)
The stability of the set can be checked by repeating the combined
operation of focus jump (layer 0t1, layer 1t0) and access to
the most inward trackymost outward track by the set number of
times or until an error occurs using the dual layer HD disc, DL
disc.
A set of operation including an access to the layer 0 (most inward
track)tlayer 0 (most outward track)tfocus jump (layer
0t1)tlayer 1 (most outward track)tlayer 1 (most inward
track)tfocus jump (layer 1t0) is carried out repeatedly by the
set number of times.
Checking Method:
1. After setting the test mode, rotate the 
[        AMS        ]
 dial to
select “92. SET CHECK” and press the 
[        AMS        ]
 dial
to enter.
2. When  “SET TEST  START” is displayed, rotate the
[        AMS        ]
 dial clockwise by 3 clicks to display “2.
F.JMP CHECK?”.
3. Press the 
[OPEN/CLOSE]
 button to open the tray, and place
the DL disc.
4. Press the 
[        AMS        ]
 dial to load the tray into the set.
5. “NOW SET UP” will be displayed and the DL disc setup will
start. (It takes about ten and several seconds to set up the disc
as two layers of layer 0 and layer 1 are adjusted)
6. At the completion of setup, “F.JUMP TIMES” will be dis-
played.
7. Rotate the 
[        AMS        ]
 dial clockwise by 5 clicks to display
“5”. (If 5 sets of operation is executed *1)
8. Press the 
[        AMS        ]
 dial, and the check will start.
9. Immediately when the check finished, “UP MAX
ssss”t“UP AVE ssss”t“DW MAX
ssss”t“DW AVE ssss”t“F.JMP OK 
[TIMES]
will be displayed repeatedly. (s denotes the measured value
in msec)
UP MAX: Max time required for layer 0 (most inward
track)tlayer 0 (most outward track)tfocus jump
(layer 0t1)
UP AVE:
Average time required for layer 0 (most inward
track)tlayer 0 (most outward track)tfocus jump
(layer 0t1)
DW MAX: Max time required for layer 1 (most outward
track)tlayer 1 (most inward track)tfocus jump
(layer 1t0)
DW AVE: Average time required for layer 1 (most outward
track)tlayer 1 (most inward track)tfocus jump
(layer 1t0)
Specified value: 7000 msec or less (if no error occurred)
If an error occurred due to defocusing during the checking,
refer to the following error list. (64 page)
10. Press the 
[OPEN/CLOSE]
 button, and the disc will be ejected
and the check will finish. Also, if the 
[        AMS        ]
 dial is
pressed in step 9, “2. F.JUMP CHK OK” will be displayed.
Then, if the 
[        AMS        ]
 dial is again pressed, “2. F.JMP
CHECK” will be displayed instantaneously and a recheck is
enabled from the step 5 in the same manner.
*1 Setting arbitrary number of times instead of 5 allows the check-
ing to be repeated by the set number of times. Also, setting 0
(zero) allows the aging check to be repeated until an error oc-
curs.
6-4. HYBRID DISC OPERATION CHECK
(• Perform as necessary)
This test checks the auto adjustment time required when the disc
is switched between HD (SACD) layer and CD layer. This test is
conducted to check the stability in switching from CD to SACD,
or SACD to CD in the HYBRID disc.
A set of operation including CD layer stop statetHD layer auto
adjustmenttHD layer TOC readingtHD layer stop statetCD
layer auto adjustmenttCD layer TOC readingtCD layer stop
state is repeated by the set number of times.
Checking Method:
1. After setting the test mode, rotate the 
[        AMS        ]
 dial to
select “92. SET CHECK” and press the 
[        AMS        ]
 dial
to enter.
2. When  “SET TEST  START” is displayed, rotate the
[        AMS        ]
 dial clockwise by 4 clicks to display “3.
HYB CHECK?”.
3. Press the 
[OPEN/CLOSE]
 button to open the tray, and place
the HYBRID disc.
4. Press the 
[        AMS        ]
 dial to load the tray into the set.
5. “NOW SET UP” will be displayed and the HYBRID disc setup
will start. (It takes about several seconds to set up the disc *1)
6. At the completion of setup, “CHANGE TIMES?” will be dis-
played.
7. Rotate the 
[        AMS        ]
 dial clockwise by 5 clicks to display
“5” (if 5 sets of operation is executed *2)
8. Press the 
[        AMS        ]
 dial, and “START” will be displayed
and the check will start. During the check, the following will
be displayed.
“CD—>HD” display: Time from switching from CD layer to
HD layer up to start of play is measured.
“HD—>CD” display: Time from switching from HD layer to
CD layer up to start of play is measured.
9. Immediately when the check finished, “CD MAX
ssss”t“CD AVE ssss”t“HD MAX
ssss”t“HD AVE ssss” will be displayed
repeatedly. (s denotes the measured value in msec)
Specified value: 10000 msec or less (if no error occurred)
If an error occurred due to defocusing during the checking,
refer to the following error list. (64 page)
10. Press the 
[OPEN/CLOSE]
 button, and the disc will be ejected
and the check will finish. Also, if the 
[        AMS        ]
 dial is
pressed in step 9, “HYB CHK OK” will be displayed. Then, if
the 
[        AMS        ]
 dial is again pressed, “HYBRID CHECK”
will be displayed instantaneously and a recheck is enabled from
the step 5 in the same manner.
*1 “NOW SET UP” display may continue for several minutes
and an error may be displayed depending on the discs. In this
case, press the 
[        AMS        ]
 dial again.
*2 Setting arbitrary number of times instead of 5 allows the check-
ing to be repeated by the set number of times. Also, setting 0
(zero) allows the aging check to be repeated until an error oc-
curs
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
68
SCD-C555ES
l
L
l
L
l
L
l
L
Measurement item
Description
Specifications (unit: second)
RL
Time required for the table to make one complete rotation.
6.0 to 7.5
(R: Clockwise rotation. L: Counter-clockwise rotation)
DOOR OP
Time required to open the panel door
<10.0
CLOSE
Time required to close the tray.
<2.3
BU UP
Time required for the BU block to perform chucking from the DOWN position
<1.3
EXOPEN
The XCHANGE OPEN time
<2.5
EXCLOSE
The EXCHANGE CLOSE time
<2.8
BU DOWN
Time required for the BU block to perform unchucking and going to the DOWN
<0.9
position
OPEN
Time required to open the tray
<2.4
DOOR CL
Time required to close the panel door.
<10.0
If the panel door cannot be opened, the time-out error is triggered
and the measurement is also stopped at this stage. Note that the
tray can push the door forcibly as the software judges the door as
it is in the OPEN state, if the door open/close detector switches
(S1022 and S1023 on the DOOR SW board) have abnormality.
6-5. CDM59 and the Door Check
Measurement of table rotation hours, tray open/close hours and
panel door open close hours can be executed together with CDM59.
Procedure
1. Enter the TEST mode. Turn the 
[         AMS        ]
 dial and select
59 Table Init. Press 
[        AMS        ]
 once (that enables the
[OPEN/CLOSE]
 key.)
2. When the message INITIAL OK appears, press the 
[OPEN/
CLOSE]
 key to eject the tray. Place a disc in the DISC1 of the
table. (Be sure to place a disc in DISC1. If a disc is placed in
any locations other than DISC1, the correct measurement can-
not be executed. Therefore, be sure to place a disc in DISC by
using the 
[DISC SKIP]
 key.)
3. Select 58 CDM Check by turning 
[        AMS        ]
 and press
[        AMS        ]
 once.
4. Measurement starts automatically.
5. When the measurement is completed, the message DOOR OP
ss.s (s is a decimal number) appears on the FL display.
6. Result of measurement can be check by turning 
[        AMS        ]
.
If any measurement item does not meet specification, a mes-
sage “ng” is displayed next to the measurement value.
7. When you want to repeat the test, press 
[        AMS        ]
 again.
8. Press the 
[OPEN/CLOSE]
 key to terminate the test and re-
move the disc.
* 1.The measurement can be performed without placing a disc.
However, the BU chucking time and unchucking time will
be slightly different from the actual values.
* 2.When the machine enters this mode once, it cannot return
to the normal test mode. If any other tests are desired, turn
off the main power once and then back on again to enter
the test mode.
Measurement items and specifications
l
L
l
L
69
SCD-C555ES
6-6 . AGING MODE
(• Perform as necessary)
6-6-1. The aging can be performed to the set in the test
mode.
The aging can be continued by the set number of times or until an
error occurs.
In the aging, the following operations are repeated.
Table turntDisc chuckingtDisc detecttServo ontAuto
adjustmenttTOC readingtPlay of first track for 5 secondtPlay
of last track for 5 secondtPlay of first track for 5 secondtDisc
unchucking
Setting Method:
1. After setting the test mode, rotate the 
[        AMS        ]
 dial to
select “94. SET AGING” and press the 
[        AMS        ]
 dial
to enter.
2. When “AGING TIMES” is displayed, rotate the 
[        AMS        ]
dial to set the number of aging times. (For the number of times,
every 10 times can be set. Setting 0 (zero) eliminates the count
limitation where the aging is repeated until an error occurs)
Note:
 Do not perform unmanned overnight aging..
3. Press the 
[        AMS        ]
 dial, and “AGING START” will be
displayed instantaneously, then “DISC IN & JOG ON” will be
displayed and the tray will come out automatically.
4. Place a disc (CD or the SACD SL disc) on the tray. In the case
of SCD-C555ES, the multiple discs can be placed. Even when
the discs (CD or the SACD SL disc) of different types are
mixed, the aging test can be performed. Use the 
[DISC SKIP]
key when placing a disc. When discs are placed in positions,
turn the 
[        AMS        ]
 dial.
5. The aging test starts.
6. At the completion of aging by the set number of times, the
tray will come out automatically and the check will stop.
Typical time required for aging    About 1 hour/100 times
“AGING SUCCESS!” will be displayed if no error occurred
in the aging, or the error will be displayed if an error occurred.
(Refer to the following error list)
6-6-2. Aging Mode of the Panel Door Independently
1. Start up the unit in the normal operation mode.
2. While press the 
[STOP]
 key, turn the 
[         AMS         ]
 dial and
then press the 
[CONTINUE]
 key. (The program does not ad-
vance if these keys are not pressed in the above sequence.)
3. The panel door repeats opening and closing.
4. The messages “AP-B 000000” (during open) t  “AP-C
000000” (during close) are repeated on the FL display. Num-
ber of times of open/close are displayed in decimal number in
“000000” with OPEN/CLOSE as a set.
5. Press the 
[STOP]
 key to terminate the aging mode and to re-
turn to the normal mode.
6-7. SHIPPING MODE
The repaired set must be initialized, and for this purpose the set
should be set to the shipping mode.
Setting Method:
1. After setting the test mode, rotate the 
[        AMS        ]
 dial to
select “8d Set Up Init” and press the 
[        AMS        ]
 dial to
enter.
2. “8D 000000000 00” will be displayed, and if the scroll starts
in the left direction, the set initialization has completed
3. Press the 
[POWER]
 button to turn the power off.
Note:
Take care not to leave the test disc in the set.
The following setups are established in the SHIPPING MODE
1. Initialization of EEPROM (IC903)
• PLAY MODE
ALL DISCS, CONTINUE
• COMMAND MODE
CD1
• LAYER SELECT
SACD
• M/2CH SELECT
MULTI
• DIGITAL FILTER
STD
• 2ch SPK MODE
2ch DIRECT
• Mch SPK MODE
Mch DIRECT
• Resetting the accumulated hours meter.
2. Chucking at the DISC1 position.
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
Error List
An error occurring during the check in the aging mode of the test mode is displayed automatically (scroll display) immediately when the
error occurred.
< How to view the error history >
1. Select “95 DISP ERROR” with the 
[        AMS        ]
 key, and press the 
[        AMS        ]
 key once.
2. The error that has occurred lastly in the set and the signal status (H = 1, L = 0) at that time are displayed on the FL display by scrolling.
(Types of the errors and the signal status that can be checked, are the same as the error display of the aging mode.)
3. Press the 
[        AMS        ]
 key once again to show the error history repeatedly.
4. When the error history is displayed with scrolling once, the mode returns to the normal test mode.