Panasonic SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC / SDR-H80GC / SDR-H80GN / SDR-H80GJ / SDR-H80GK / SDR-H80PU / SDR-H80PR / SDR-H81EE / SDR-H81EB / SDR-H90P / SDR-H90PC / SDR-H90EG / SDR-H90EE / SDR-H90EB / SDR-H Service Manual ▷ View online
Panasonic
Corporation
2008.
Model No.
SDR-H80P
SDR-H80PC
SDR-H80EG
SDR-H80EE
SDR-H80EB
SDR-H80EP
SDR-H80EF
SDR-H80EC
SDR-H80EG
SDR-H80EE
SDR-H80EB
SDR-H80EP
SDR-H80EF
SDR-H80EC
SDR-H80GC
SDR-H80GN
SDR-H80GJ
SDR-H80GK
SDR-H80PU
SDR-H80PR
SDR-H81EE
SDR-H81EB
SDR-H90P
SDR-H90PC
SDR-H90EG
SDR-H90EE
SDR-H90EB
SDR-H90EP
SDR-H90EF
SDR-H90EC
SDR-H90GC
SDR-H90GN
SDR-H90GJ
SDR-H90GK
SD Card / Hard Disk Video Camera
ORDER NO.VM0812041CE
B27
SDR-H90PU
VOL.1
Colours
1
Safety Precaution
3
1.1.
General Guidelines
3
2
Warning
4
2.1.
Prevention of Electrostatic Discharge (ESD) to
Electrostatic Sensitive (ES) Devices
4
2.2.
Service caution based on legal restrictions
5
2.3.
Caution for AC Cord (For EB/GC)
6
2.4.
How to Replace the Lithium Battery (PROCEDURE)
7
2.5.
How to Recycle the Lithium Battery (U.S. Only)
8
3
Service Navigation
9
3.1.
Service Information
9
3.2.
Precautions for Handling HDD
11
3.3.
Formatting HDD
15
4
Specifications
16
5
Location of Controls and Components
17
6
Service Mode
19
6.1.
Service Menu
19
6.2.
About Default Setting
25
7
Service Fixture & Tools
26
7.1.
Service Tools and Equipment
26
8
Disassembly and Assembly Instructions
27
8.1.
Disassembly Flow Chart
27
8.2.
P.C.B. Layout
27
8.3.
Disassembly Procedures
28
8.4.
Disassembly Procedures of Camera Lens Unit
33
9
Measurements and Adjustments
34
9.1.
EEPROM Data for spare parts of the SUB P.C.B.
34
(K)........Black Type (except DMR-H80GK)
(S)........Silver Type (except DMR-H80EF, H81, H90)
(A)........Blue Type (except DMR-H80EF/EE, H81, H90)
(R)........Red Type (except DMR-H80EE, H81, H90)
9.2.
Service Positions
34
9.3.
Location for Connectors of the Main P.C.B. and Sub
P.C.B.
36
9.4.
Electrical Adjustment Procedures
38
10 Maintenance
42
10.1. Cleaning Lens and LCD Panel
42
11 Schematic Diagrams
43
11.1. OVERALL SCHEMATIC DIAGRAM
43
11.2. INTERCONNECTION SCHEMATIC DIAGRAM
44
11.3. REAR SCHEMATIC DIAGRAM
46
11.4. LCD BL SCHEMATIC DIAGRAM
47
11.5. HDD RELAY FPC SCHEMATIC DIAGRAM
48
11.6. LCD SHAFT FPC SCHEMATIC DIAGRAM
49
11.7. TERMINAL FPC SCHEMATIC DIAGRAM
50
11.8. LCD OPERATION UNIT SCHEMATIC DIAGRAM
50
11.9. ECM FPC SCHEMATIC DIAGRAM
51
11.10. LIGHT SCHEMATIC DIAGRAM (SDR-H81EE ONLY)
51
11.11. MODE OPERATION SCHEMATIC DIAGRAM
52
11.12. CCD SCHEMATIC DIAGRAM
52
12 Printed Circuit Board
53
12.1. LCD BL P.C.B.
53
12.2. REAR P.C.B.
54
12.3. LIGHT P.C.B. (SDR-H81EE ONLY)
54
13 Parts and Exploded Views
55
13.1. Exploded Views
55
13.2. Replacement Parts List
59
14 Schematic Diagram for printing with A4
65
CONTENTS
Page
Page
2
SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect “A” to exposed metallic part on the set. And
connect “B” to a good earth ground, as shown in .
3. Use an AC voltmeter, with 1 k
W/V or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.25 V RMS.
A leakage current tester (Simpson Model 229 or equivalent)
may be used to make the hot checks, leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of a shock hazard,
and the equipment should be repaired and rechecked
before it is returned to the customer.
may be used to make the hot checks, leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of a shock hazard,
and the equipment should be repaired and rechecked
before it is returned to the customer.
Figure 1
1 Safety Precaution
1.1. General Guidelines
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by in the
Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts
should be replaced with manufacturer’s specified parts to prevent X-RADIATION, shock fire, or other hazards. Do not modify
the original design without permission of manufacturer.
Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts
should be replaced with manufacturer’s specified parts to prevent X-RADIATION, shock fire, or other hazards. Do not modify
the original design without permission of manufacturer.
2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC
power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury
from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during
servicing.
from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during
servicing.
3. When servicing, observe the original lead dress. It a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
chassis, the reading should be between 1M
W and 5.2MW. When the exposed metal does not have a return path to the chassis,
the reading must be infinity.
1.1.2. Leakage current hot check (See Figure 1)
3
SDR-H80P
2 Warning
2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatic Sensitive
(ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called
Electrostatic Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electrostatic discharge (ESD).
Electrostatic Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an antistatic solder removal device. Some solder removal devices not classified as “antistatic (ESD protected)” can
4. Use only an antistatic solder removal device. Some solder removal devices not classified as “antistatic (ESD protected)” can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable
conductive material).
conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
CAUTION:
CAUTION:
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the
brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD)
sufficient to damage an ES device).
sufficient to damage an ES device).
4
SDR-H80P