DOWNLOAD Sony SCD-C555ES Service Manual ↓ Size: 16.88 MB | Pages: 93 in PDF or view online for FREE

Model
SCD-C555ES
Pages
93
Size
16.88 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
scd-c555es.pdf
Date

Sony SCD-C555ES Service Manual ▷ View online

57
SCD-C555ES
Cleaning of Optical Pick-up Lens
In cleaning the lens of optical pick-up, use the air blower.
Never use a cotton swab for cleaning the lens of optical pick-up, which otherwise causes a trouble.
Resetting Operation at Power ON
If the power is turned on with a disc loaded in the set, a sequence of operation as shown below will be performed.
(The operation varies depending on the type of disc)    Condition: continue mode
(1) CD
 1.
Sled reverse move (sled in)
 2.
Disc detect
 3.
IC setting for CD
 4.
Servo error signal offset auto adjustment
 5.
Spindle kick for LD on
 6.
LD on
 7.
Focus search
 8.
Focus servo on
 9.
Spindle kick
 10. Spindle servo on
 11. E-F balance auto adjustment
 12. Tracking & sled servo on
 13. Focus bias auto adjustment
 14. Focus servo gain auto adjustment
 15. Tracking servo gain auto adjustment
 16. Jump to lead-in area
 17. Read TOC
 18. Stop
(2) SACD (single layer)
 1.
Sled reverse move (sled in)
 2.
Disc detect
 3.
IC setting for SACD
 4.
Servo error signal offset auto adjustment
 5.
Spindle kick for LD on
 6.
LD on
 7.
Focus search
 8.
Focus servo on
 9.
Spindle kick
 10. Spindle servo on
 11. E-F balance auto adjustment
 12. Tracking & sled servo on
 13. Focus bias auto adjustment
 14. Focus servo gain auto adjustment
 15. Tracking servo gain auto adjustment
 16. Jump to lead-in area
 17. Read TOC
 18. Stop
SECTION  5
SERVICING NOTES (2)
(3) SACD (dual layer)
 1.
Sled reverse move (sled in)
 2.
Disc detect
 3.
IC setting for SACD
 4.
Servo error signal offset auto adjustment
 5.
Spindle kick for LD on
 6.
LD on
 7.
Focus search
 8.
Focus servo on (layer 0)
 9.
Spindle kick
 10. Spindle servo on
 11. E-F balance auto adjustment (layer 0)
 12. Tracking & sled servo on (layer 0)
 13. Focus bias auto adjustment (layer 0)
 14. Focus servo gain auto adjustment (layer 0)
 15. Tracking servo gain auto adjustment (layer 0)
 16. Jump to lead-in area
 17. Read TOC
 18. Focus jump (layer 0tlayer 1)
 19. E-F balance auto adjustment (layer 1)
 20. Tracking & sled servo on (layer 1)
 21. Focus bias auto adjustment (layer 1)
 22. Focus servo gain auto adjustment (layer 1)
 23. Tracking servo gain auto adjustment (layer 1)
 24. Focus Jump (layer 1tlayer 0)
 25. Stop
58
SCD-C555ES
FLUORESCENT INDICATOR TUBE MODE
Note:
Set the 
[CD1/CD2]
 switch on the remote commander to CD1.
Procedure:
1. While shorting the Test Land and the GND side of C1002 (Dis-
play board) with tweezers, press the 
[POWER]
 button and turn
on the main power. The following operations will be executed
automatically.
1
Grid of all segments lights up sequentially starting from 1G
to 16G.
2
 The vertical line (total 5 lines) of all grids lights up sequen-
tially in the range of 3G to 16 G starting from the left.
3
 The horizontal line of (total 7 lines) of all grids lights up
sequentially in the range of 3G to 16G starting from the top.
4
 Grids from 5G to 6G go off.
2. With the machine in the status that is set in step 1-4, press
any on the remote commander. The grids 1G and 2G go off
and then the machine enters the key check standby state. (When
the 
[EJECT]
 key or the 
[STOP]
 key is pressed, the reception
check is canceled.)
3. After the key check is completed, turn JOG clockwise to turn
on the calendar segments sequentially. When the segment “15”
is confirmed, turn JOG counter-clockwise that turns off the
calendar segment. When the segment “1” is confirmed, this is
the end of check.
4. After all the checks are completed, confirm to see that the dis-
play  “!%%TEST-END!!%” appears. The message indicates
that the check is ended normally.
5. Press the 
[POWER]
 button to turn off the main power and
disconnect the power plug from the wall outlet.
SECTION 6
TEST MODE
59
SCD-C555ES
Test Mode Command List
The contents of test mode are as follows.
Note:
Wrong operation in the test mode causes a trouble, thus requiring extreme care.
LINE command (1X): Use mainly for a manufacturing line.
No.
Name
Description
Remarks
05
DSP MON1
XUGF, XPCK, C2PO outputted from IC509 (CD DSP)
Not used for the servicing
06
DSP MON2
MNT0, MNT1, MNT2, MNT3 outputted from IC509 (CD DSP)
Not used for the servicing
07
DSP MON3
RFCK, XPCK, XROF, GTOP outputted from IC509 (CD DSP)
Electrical measurement,
CD CLV jitter measurement
STANDARD command (1X): Use when the servo is applied by manual operation.
No.
Name
Description
Remarks
12
LD ON/OFF
The laser diode is turned on or off
On or off are switched alternately
13
SPIN ON/OFF
The spindle motor is rotated with the regulated voltage
On or off are switched alternately
14
FSRV ON/OFF
The focus servo is turned on or off
On or off are switched alternately
15
TSRV ON/OFF
The tracking servo is turned on or off
On or off are switched alternately
16
CLV ON/OFF
The spindle SLV servo is turned on or off
On or off are switched alternately
Focus and tracking servos must be already turned on
17
SSRV ON/OFF
The sled servo is turned on or off
On or off are switched alternately
Focus, tracking and spindle servos must be already turned on
18
ALL SRV ON
All servos are turned on
19
ALL SRV OFF
All servos are turned off
Stop command in the test mode
This set automatically executes self-diagnosis and various checks
by entering the test mode.
Note:
 This set automatically makes various adjustments according to the
type of disc, thereby not requiring adjustment of the set when parts
were replaced. However, be sure to execute 6-1. IC AND FLUO-
RESCENT DISPLAY TUBE CHECK, 6-2. AUTO CHECK and 6-
8. WAVEFORMS CHECK.
Disc for Test Mode
Various checks of this set require the following discs.
Model
Type 
*
1
Category
Application
MODEL
SATD-S5
12 cm disc
Adjusted value check,
(J-2501-215-A) SL
Reference disc
Operation check,
SATD-S4
Optical waveform check
(J-2501-184-A)
Not specified
DL
12 cm disc
Operation check
PATD-012
Adjusted value check,
(4-225-203-01)
CD
12 cm disc
Operation check,
YEDS-18
Reference disc
Optical waveform check
(3-702-101-01)
Not specified
HYBRID 12 cm disc
Operation check
*1 SL: Single Layer
DL: Dual Layer
Setting Method of Test Mode
Turn the 
[POWER]
 switch on while pressing the 
[        AMS        ]
dial and the 
[TIME/TEXT]
 button. Release the 
[TIME/TEXT]
 button
and the 
[        AMS        ]
 dial in this order when “TEST MODE
Menu” is displayed on the fluorescent display tube. (If the
[        AMS         ]
 dial is released first, the test mode becomes active
but “TEST MODE Menu” is not displayed)
[OPEN/CLOSE]
 key in the TEST mode.
The 
[OPEN/CLOSE]
 key is disabled immediately after the ma-
chine enters the TEST mode. Be sure to turn the 
[        AMS        ]
dial to select 59 Table Init and push 
[        AMS        ]
 once. When
initial-ization of the table is completed, the message INITAIL OK
appears several seconds on the FL display. After this, the 
[OPEN/
CLOSE]
 key is enabled and disc can be inserted and ejected.
When the command 59 Table Init is executed, the same operations
of the POWER ON to the disc chucking in the normal operations
as described below are performed. However, it presumes that the
door and the tray are closed depending on the stop status.
59 Table Init 
t
 BU DOWN (disc unchucking) 
t
 Table rotates
(disc search) 
t
 BU UP (disc chucking) at the disc that is found
first of all.
When there are no discs, BU UP is executed at the DISC1 posi-
tion.
Releasing Method of Test Mode
To release the test mode, turn the 
[POWER]
 switch off.
Selection/Entry of Test Mode
To select and enter the “TEST MODE Menu”, operate as follows.
1. Rotate the 
[        AMS        ]
 dial to select the menu, and press
the 
[        AMS        ]
 dial to enter.
2. The test is switched on or off alternately each time the
[        AMS        ]
 dial is pressed.
3. To return to the previous step, rotate the 
[        AMS        ]
 dial
to select the desired item, and press the 
[        AMS        ]
 dial
to enter.
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
60
SCD-C555ES
FOCUS command (2X): Focus related. (All servos must be already turned on (except command 21))
No.
Name
Description
Remarks
21
FSRCH ON/OFF
The continuous vertical motion of the optical pick-up lens is turned on or
Avoid a long-time use
off
22
F-BIAS UP
Increase focus bias
Focus bias value
23
F-BIAS DOWN
Decrease focus bias
Focus bias value
24
ADJ FCSBIAS
The focus bias is adjusted automatically
Both + and - directions are searched to search for best jitter point
25
FGAIN UP/DW
The focus servo gain is switched between normal and down
Normal or down are switched alternately
26
FJMP UP/DWN
Focus jump is executed
Valid only for DL
UP: layer 0t1, DOWN: layer 1t0
27
FOCUS AGC
The focus servo gain is adjusted automatically
28
DISP FBdata
The focus bias adjusted value is displayed
Hexadecimal display 9 bit data
Note:
On or off and up or down are switched alternately
OFFSET (PI, FE, TE) command (3X): Adjusts the offset of PI, FE and TE signals.
No.
Name
Description
Remarks
31
PI/FE OFSET
Adjusts the offset of PI, FE and TE signals
TE offset adjustment is executed for the CD
This adjustment must be executed after 61 DISC DETECT
only
TRACKING command (4X): Tracking servo related.
No.
Name
Description
Remarks
41
TGAIN NM/UP
The tracking servo gain is switched between normal and up
Normal or up are switched alternately
44
ADJ TRK DSP
The traverse AGC and E-F balance adjustment is performed
45
TRACKING AGC
The tracking servo gain is adjusted automatically
SEARCH command (5X): Track search related. (Nos. 51 through 53 are not used for the servicing.)
No.
Name
Description
Remarks
51
1-TRCK JUMP
One-track jump is performed
52
M-TRCK MOVE
M-track movement is performed
53
FINE SEARCH
Fine search is performed
58
CDM Check
Measurement of table rotation hours, tray open/close hours and panel door
open close hours
59
Table Init
Initializes the table.
After this command, the [OPEN/CLOSE]
key is enabled.
DISC DETECT command (6X): Disc type check related.
No.
Name
Description
Remarks
61
DISC DETECT
Disc type check is executed
Refer to how to apply servo by manual
Display after judgment
operation (62 page)
DSKMOD CD: Judged as CD
DSKMOD SL: Judged as SACD (SL)
DSKMOD DL: Judged as SACD (DL)
DSKMOD HLHD: Judged as HYBRID HD
DSKMOD CDRW: Judged as CD-RW
62
SET DISC CD
Enter disc type    CD setting
CD forced setting
63
SET DISC SL
Enter disc type    SL setting
SL forced setting
64
SET DISC DD
Enter disc type    DD setting
DD forced setting
65
SET DISC HH
Enter disc type    HYBRID HD setting
HD forced setting
66
SET DISC HC
Enter disc type    HYBRID CD setting
CD forced setting
Page of 93
Display