DOWNLOAD Sony MDS-B6P Service Manual ↓ Size: 1.12 MB | Pages: 58 in PDF or view online for FREE

Model
MDS-B6P
Pages
58
Size
1.12 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / SM MDSB6P 97 US,CAN,AEP,UK
File
mds-b6p.pdf
Date

Sony MDS-B6P Service Manual ▷ View online

— 33 —
3-5. Functions of Other Buttons
Note : The erasing-protection tab is not detected during the test mode. Recording will start regardless of the position of the erasing-protection
tab when the 
r (REC) button is pressed.
Contents
Sets continuous playback when pressed in the STOP state. When pressed during continuous playback, the tracking servo turns ON/OFF.
Stops continuous playback.
The sled moves to the outer circumference only when this is pressed.
The sled moves to the inner circumference only when this is pressed.
Switches between the pit and groove modes when pressed.
Switches the spindle servo mode (CLVS and A).
Switches the display when pressed.Returns to previous step. Stops operations.
Function
^
p
)
0
SINGLE
A. MODE
DISPLAY
3-6. Test Mode Displays
Each time the DISPLAY button is pressed, the display changes in the following order.
MODE display
nError rate displaynAddress display
1. MODE display
Displays “TEMP ADJUST”, “CPLAY MODE”, etc.
2. Error rate display
Error rates are displayed as follows.
C1 = 
AD = 
C1 = : Indicates C1 error
AD = : Indicates ADER
3. Address display
Addresses are displayed as follows.
h = 
s = 
 (MO pit and CD)
h = 
a = 
 (MO groove)
h = : Header address
s = : SUBQ address
a = : ADIP address
* is displayed when the address cannot be read.
3-7. Meanings of Other Displays
During continuous playback
Tracking servo OFF
CLV LOCK
Pit
High reflection
CLV-S
ABCD adjustment completed
STOP
Tracking servo ON
CLV UNLOCK
Groove
Low reflection
CLV-A
Display
Contents
Light
Off
Blinking
^ LED
e LED
SYNC
TRACK
DISC
SPEED
A. PAUSE
REPEAT 1
Focus auto gain successful
Tracking auto gain failed
3-8. Precautions for Use of Test Mode
1 As loading related operations will be performed regardless of the test mode operations being performed, be sure to check that the disc is
stopped before setting and removing it.
Even if the EJECT button is pressed while the disc is rotating during continuous playback, the disc will not stop rotating.
Therefore, it will be ejected while rotating.
Always press the EDIT/NO button first before pressing the EJECT button.
2 Most buttons can not be used while the error rate is displayed due to bugs of IC121 CXD2535CR.
Focus auto gain successful
Tracking auto gain failed
— 34 —
4-1. Precautions for Checking Laser Diode
Emission
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
4-2. Precautions for Use of Optical Pick-up
(KMS-210A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connect-
ing the connector, be careful not to remove the solder. Also take ad-
equate measures to prevent damage by static electricity. Handle the
flexible board with care as it breaks easily.
SECTION  4
ELECTRICAL ADJUSTMENTS
4-3. Precautions for Adjustments
1) When replacing the following parts, perform the adjustments and
checks with 
® in the order shown in the following table.
Optical
Pick-up
BD Board
G
®
®
®
®
®
®
®
®
®
®
G
G
G
®
®
®
®
®
1. Temperature
compensation
offset adjustment
2. Laser power
adjustment
3. Traverse
adjustment
4. Focus bias
adjustment
5. Error rate check
IC171
IC101, IC121, IC191
D101
G
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
3) Perform the adjustments in the order shown.
4) Use the following tools and measuring devices.
• MD test disc (CD) MDW-74/AU-1 (Parts No. 8-892-341-41)
• MD test disc TDYS-1
(Parts No. 4-963-646-01)
• Laser power meter LPM-8001
(Parts No. J-2501-046-A)
• Oscilloscope
• Digital voltmeter
• Thermometer
5) When observing several signals on the oscilloscope, etc.,
make sure that VC and GND do not connect inside the oscillo-
scope.
(VC and GND will become short-circuited.)
Optical pick-up flexible board
laser tap
— 35 —
4-4. Temperature Compensation Offset Adjustment
Save the temperature data at that time in the non-volatile memory as
25 ˚C reference data.
Note :
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28
˚C. Perform it immediately after the power is turned on when the
internal temperature of the unit is the same as the ambient tem-
perature.
3. When D101 has been replaced, perform this adjustment after the
temperature of this part has become the ambient temperature.
Adjusting Method :
1. Rotate the AMS knob and display “TEMP ADJUST”.
2. Press the ENTER/YES button and select the “TEMP ADJUST”
mode.
3. “TEMP = 
” and the current temperature data will be displayed.
4. To save the data, press the ENTER/YES button.
When not saving the data, press the EDIT/NO button.
5. When the ENTER/YES button is pressed, “TEMP = 
 SAVE”
will be displayed for some time, followed by “TEMP ADJUST”.
When the EDIT/NO button is pressed, “TEMP ADJUST” will be
displayed.
Specifications :
The “TEMP =  
” should be within “E0 - EF”, “F0 - FF”, “00 - 0F”,
“10 - 1F” and “20 - 2F”.
4-5. Laser Power Adjustment
Connection :
+0.1
–0
Laser power
meter
Optical pick-up
objective lens
Digital voltmeter
KMS
210A
27X40
B0825
n
lop = 82.5 mA in this case
lop (mA) = Digital voltmeter reading (mV)/ 1 (
)
7. Press the ENTER/YES button and display “LD $ 0F = 0.7 mW”.
(Laser power: MO reading)
8. Check that the laser power meter at this time satisfies the speci-
fied value.
Specification :
Laser power meter reading : 0.70 ± 0.1 mW
9. Press the EDIT/NO button and display “LDPWR ADJUST’, and
stop laser emission.
(The EDIT/NO button is effective at all times to stop the laser
emission.)
BD board
TP (I + 5V)
TP (IOP)
Adjusting Method :
1. Set the laser power meter on the objective lens of the optical pick-
up. (When it cannot be set properly, press the 
0 button or )
button and move the optical pick-up.)
Connect the digital volt meter to TP (IOP) and TP (I+5V).
2. Rotate the AMS knob and display “LDPWRADJUST”.
(Laser power : For adjustment)
3. Press the ENTER/YES button twice and display “LD $ 4B = 3.5
mW”.
4. Adjust RV102 of the BD board so that the reading of the laser
power meter becomes 3.4
 mW.
5. Press the ENTER/YES button and display “LD $ 96 = 7.0 mW”.
(Laser power:MO reading)
6. Check that the laser power meter and digital voltmeter readings
satisfy the specified value.
Specification :
Laser power meter reading : 7.0 ± 0.3 mW
Digital voltmeter reading : Optical pick-up displayed value ± 10%
(Optical pick-up label)
— 36 —
4-6. Traverse  Adjustment
Connection :
11. Rotate the AMS knob until the waveform of the oscilloscope
moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 3%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
Oscilloscope
BD board
TP (TEO)
TP (VC)
Adjusting method :
1. Connect an oscilloscope to TP (TEO) and TP (VC) of the BD
board.
2. Load a MO disc (any available on the market).
3. Press the 
0 button or ) button and move the optical pick-up
outside the pit.
4. Rotate the AMS knob and display “EFBAL ADJUST”.
5. Press the ENTER/YES button and display “EFBAL MO-W”.
(Laser power WRITE power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Adjust RV101 of the BD board so that the waveform of the oscil-
loscope becomes the specified value.
(MO groove write power traverse adjustment)
(Traverse Waveform)
VC
A
B
VC
A
B
Specification A = B
7. Press the ENTER/YES button and display “EFB = $   MO-R”.
(Laser power : MO reading)
8. Rotate the AMS knob so that the waveform of the oscilloscope
becomes the specified value.
(When the AMS knob is rotated, the   of “EFB-   ” changes and
the waveform changes.) In this adjustment, waveform varies at
intervals of approx. 3%. Adjust the waveform so that the speci-
fied value is satisfied as much as possible.
(MO groove read power traverse adjustment)
(Traverse Waveform)
VC
A
B
Specification A = B
9. Press the ENTER/YES button, display “EFB = $   SAVE” for a
moment and save the adjustment results in the non-volatile
memory.
Next “EFBAL MO-P” is displayed.
10. Press the ENTER/YES button and display “EFB = $   MO-P”.
The optical pick-up moves to the pit area automatically and servo
is imposed.
Specification A = B
VC
A
B
12. Press the ENTER/YES button, display “EFB =   SAVE” for a
moment and save the adjustment results in the non-volatile
memory.
Next “EFBAL CD” is displayed. The disc stops rotating auto-
matically.
13. Press the EJECT button and remove the MO disc.
14. Load the test disc TDYS-1.
15. Press the ENTER/YES button and display “EFB =   CD”. Servo
is imposed automatically.
16. Rotate the AMS knob so that the waveform of the oscilloscope
moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 3%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
Specification A = B
17. Press the ENTER/YES button, display “EFB = $   SAVE” for a
moment and save the adjustment results in the non-volatile
memory.
Next “EFBAL ADJUST” is displayed.
18. Press the EJECT button and remove the test disc TDYS-1.
Note 1)
If the traverse waveform is not clear, connect the oscillo-
scope as shown in the following figure so that it can be
seen more clearly.
Oscilloscope
330k
10pF
TP (TEO)
TP (VC)
Page of 58