Sony MDS-B6P Service Manual ▷ View online

— 29 —
SECTION  2
DISASSEMBLY
Note:
 Follow the disassembly procedure in the numerical order given.
2-1. CASE AND FRONT PANEL ASSEMBLY
2-2. BACK PANEL
1
Two screws (+B4x8)
4
Case
7
Front panel assembly
5
Two screws (+BVTT3x8)
6
Wire (Flat type) (16 core)
2
Two screws (+B4x8)
3
Screw (+BVTT3x8)
6
Back panel
1
Four hexagon
screws (M2.6)
2
Three screws
(+B3x5)
4
Three screws
(+B3x5)
5
Three screws (+BVTT3x8)
3
Two screws (+BVTP4x10)
— 30 —
2-3. MECHANISM DECK
A
B
Slider
1
Two screws
(+B2.6x18)
2
Two collars
Pulley (BD)
3
Rotate the pulley (BD) in the direction
of arrow 
A
, and slide the slider (M)
assembly in the direction of arrow 
B
.
(As the stopper catches halfway, lightly
push up the stopper in the fig. A to
release, then rotate the pulley (BD) in
the direction of arrow 
A
.
4
Two screws
(+B2.6x18)
5
Two collares
6
Screw (+BVTT2.6x4)
7
Earth lug
8
Two MD insulators
9
Two compression springs
0
MD
insulator
Compression spring
!™
MD insulator
Compression spring
MD mechanism deck
Fig. A
Bracket (BD)
Lever (SLM)
Torsion spring (SLM)
Slider (M) assembly
3
Screw (+PTT2x4)
4
Earth lug
1
Disengage a torsion spring
from the claw 
A
.
2
Disengage the claw 
B
, raise the
lever (SLM) upwards to remove.
A
 Claw
B
 Claw
D
C
 Claw
5
Move the claw 
C
 on the slider up to the
base rail in the direction of arrow 
D
 to
remove, and remove it in the direction of
arrow 
E
.
E
Base rail
2-4. SLIDER
— 31 —
2-5. BASE UNIT (MBU-2B6P), LOADING MOTOR ASSEMBLY
1
Screw (+BVTP3x6)
4
Belt (BD)
5
Two screws (+B2.6x5)
6
Connector (CN192)
7
Loading motor assembly
3
MD base unit (MBU-2B6P)
2-6. SLIDER ASSEMBLY MOUNTING
1
Set the four left and right projections of
lever to the position as in the figure.
2
Rotate fully the lever (SLM)
in arrow direction 
A
.
4
Move the slider assembly in arrow direction
B
, and lock it to the lever (SLM).
3
Rotate the pully (BD)
in arrow 
C
 direction.
A
B
C
2
Two screws
(+BVTP3x6)
— 32 —
3-1. Setting the Test Mode
While pressing the AMS knob, turn POWER switch on, and release the AMS knob.
3-2. Exiting the Test Mode
Turn POWER switch off.
3-3. Basic Operations of the Test Mode
All operations are performed using the AMS knob, ENTER/YES button, and EDIT/NO button.
The functions of these buttons are as follows.
SECTION  3
TEST MODE
Contents
Changes parameters and modes
Proceeds onto the next step. Finalizes input.
Returns to previous step. Stops operations.
Function
AMS knob
ENTER/YES button
EDIT/NO button
3-4. Selecting the Test Mode
Twelve test modes are selected by turning the AMS knob.
Display
TEMP ADJUST
LDPWR ADJUST
EFBAL ADJUST
FBIAS ADJUST
FBIAS CHECK
CPLAY MODE
Contents
Temperature compensation offset adjustment
Laser power adjustment
Traverse adjustment
Focus bias adjustment
Focus bias check
Continuous playback mode
Display
EP MODE
VERSION DISP
RS232C CHECK
PARA-RMT CHK
HOURS MT DISP
SETUP INIT
Contents
Non-volatile memory mode *
Micro computer soft version
RS232C check *
Parari mode check *
Hours meter operating mode
Setup initialize mode
For detailed description of each adjustment mode, refer to 4. Electrical Adjustments.
If a different adjustment mode has been selected by mistake, press the EDIT/NO button to exit from it.
* The EP MODE, RS232C CHECK and PARA-RMT CHK is not used in servicing. If set accidentally, press the EDIT/NO button immediately
to exit it.
3-4-1. Operating the Continuous Playback Mode
1. Entering the continuous playback mode
1 Set the disc in the unit (Whichever recordable discs or discs for playback only are available.)
2 Rotate the AMS knob and display “CPLAY MODE”.
3 Press the ENTER/YES button to change the display to “CPLAYIN”.
4 When access completes, the display changes to “C1 = 
 AD = 
”.
Note : The “ ” displayed are arbitrary numbers.
2. Changing the parts to be played back
1 Press the ENTER/YES button during continuous playback to change the display to “CPLY MID”, “CPLAY OUT”.
When pressed another time, the parts to be played back can be changed.
2 When access completes, the display changes to “C1 = 
 AD = 
”.
Note : The “ ” displayed are arbitrary numbers.
3. Ending the continuous playback mode
1 Press the EDIT/NO button. The display will change to “CPLY MODE”.
2 Press the EJECT button and remove the disc.
Note 1 : The playback start addresses for IN, MID, and OUT are as follows.
IN
40h cluster
MID
300h cluster
OUT
700h cluster
3-4-2. Non-Volatile Memory Mode
This mode reads and writes the contents of the non-volatile memory.
It is not used in servicing. If set accidentally, press the EDIT/NO button immediately to exit it.