DOWNLOAD Sony MDS-B5 Service Manual ↓ Size: 1.27 MB | Pages: 65 in PDF or view online for FREE

Model
MDS-B5
Pages
65
Size
1.27 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
mds-b5.pdf
Date

Sony MDS-B5 Service Manual ▷ View online

— 37 —
3-4-2. Operating the Continuous Recording Mode
1. Entering the continuous recording mode
1 Set the MO disc in the unit.
2 Rotate the AMS knob and display “CREC MODE”.
3 Press the ENTER/YES button to change the display to “CREC IN”.
4 When access completes, the display changes to “CREC (
)”.
Note : The “ ” displayed are arbitrary numbers.
2. Changing the parts to be recorded
1 When the ENTER/YES button is pressed during continuous recording, the display changes to “CREC MID”, “CREC OUT” .
When pressed another time, the parts to be recorded can be changed.
2 When access completes, the display changes to “CREC (
)”.
Note : The “ ” displayed are arbitrary numbers.
3. Ending the continuous recording mode
1 Press the EDIT/NO button. The display changes to “CREC MODE”.
2 Press the EJECT button and remove the disc.
Note 1 :
The recording start addresses for IN, MID, and OUT are as follows.
IN
40h cluster
MID 300h cluster
OUT 700h cluster
Note 2 :
The EDIT/NO button can be used to stop recording anytime.
Note 3 :
During the test mode, the erasing-protection tab will not be detected. Therefore be careful not to set the continuous recording mode
when a disc not to be erased is set in the unit.
Note 4 :
Do not perform continuous recording for long periods of time above 5 minutes.
Note 5 :
During continuous recording, be careful not to apply vibration.
3-4-3. Non-Volatile Memory Mode
This mode reads and writes the contents of the non-volatile memory.
It is not used in servicing. If set accidentally, press the EDIT/NO button immediately to exit it.
3-5. Functions of Other buttons
Contents
Sets continuous playback when pressed in the STOP state. When pressed during continuous playback, the tracking servo turns ON/OFF.
Stops continuous playback and continuous recording.
The sled moves to the outer circumference only when this is pressed.
The sled moves to the inner circumference only when this is pressed.
Turns recording ON/OFF when pressed during continuous playback.
Switches between the pit and groove modes when pressed.
Switches the spindle servo mode (CLVS and A).
Switches the display when pressed.Returns to previous step. Stops operations.
Function
^
p
)
0
r
SINGLE
A. MODE
DISPLAY
Note : The erasing-protection tab is not detected during the test mode. Recording will start regardless of the position of the erasing-protection
tab when the 
r (REC) button is pressed.
— 38 —
During continuous playback
Tracking servo OFF
Recording mode ON
CLV LOCK
Pit
High reflection
CLV-S
ABCD adjustment completed
STOP
Tracking servo ON
Recording mode OFF
CLV UNLOCK
Groove
Low reflection
CLV-A
Display
Contents
Light
Off
Blinking
^ LED
e LED
REC 
r LED
SYNC
TRACK
DISC
SPEED
A. PAUSE
REPEAT 1
Focus auto gain successful
Tracking auto gain failed
Focus auto gain successful
Tracking auto gain failed
3-8. Precautions for Use of Test Mode
1 As loading related operations will be performed regardless of the test mode operations being performed, be sure to check that the disc is
stopped before setting and removing it.
Even if the EJECT button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc will not stop
rotating.
Therefore, it will be ejected while rotating.
Always press the EDIT/NO button first before pressing the EJECT button.
2 The erasing-protection tab is not detected in the test mode. Therefore, when modes which output the recording laser power such as continu-
ous recording mode and traverse adjustment mode, etc. are set, the recorded contents will be erased regardless of the position of the tab.
When using a disc that is not to be erased in the test mode, be careful not to enter the continuous recording mode and traverse adjustment
mode.
3 Most buttons can not be used while the error rate is displayed due to bugs of IC121 CXD2535CR.
3-6. Test Mode Displays
Each time the DISPLAY button is pressed, the display changes in the following order.
MODE display
nError rate displaynAddress display
1. MODE display
Displays “TEMP ADJUST”, “CPLAY MODE”, etc.
2. Error rate display
Error rates are displayed as follows.
C1 = 
AD = 
C1 = : Indicates C1 error
AD = : Indicates ADER
3. Address display
Addresses are displayed as follows.
h = 
s = 
 (MO pit and CD)
h = 
a = 
 (MO groove)
h = : Header address
s = : SUBQ address
a = : ADIP address
* is displayed when the address cannot be read.
3-7. Meanings of Other Displays
— 39 —
4-1. Precautions for Checking Laser Diode
Emission
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
4-2. Precautions for Use of optical pickup
(KMS-210A)
As the laser diode in the optical pickup is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connect-
ing the connector, be careful not to remove the solder. Also take ad-
equate measures to prevent damage by static electricity. Handle the
flexible board with care as it breaks easily.
SECTION  4
ELECTRICAL ADJUSTMENTS
4-3. Precautions for Adjustments
1) When replacing the following parts, perform the adjustments and
checks with 
® in the order shown in the following table.
Optical
Pick-up
BD Board
G
®
®
®
®
®
®
®
®
®
®
G
G
G
®
®
®
®
®
1. Temperature
compensation
offset adjustment
2. Laser power
adjustment
3. Traverse
adjustment
4. Focus bias
adjustment
5. Error rate check
IC171
IC101, IC121, IC191
D101
G
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
3) Perform the adjustments in the order shown.
4) Use the following tools and measuring devices.
• MD test disc (CD) TDYS-1
(Parts No. 4-963-646-01)
• Laser power meter LPM-8001 (Parts No. J-2501-046-A)
• Oscilloscope
• Digital voltmeter
• Thermometer
5) When observing several signals on the oscilloscope, etc.,
make sure that VC and GND do not connect inside the oscillo-
scope.
(VC and GND will become short-circuited.)
4-4. Creating MO Continuously Recorded Disc
* This disc is used in focus bias adjustment and error rate check. The
following describes how to create a MO continuous recording disc.
1. Insert a MO disc (blank disc) commercially available.
2. Rotate the AMS knob and display “CREC MODE”.
3. Press the ENTER/YES button and display “CREC IN”.
4. Press the ENTER/YES button again to display “CREC MID”.
“CREC (0300)” is displayed for a moment and recording starts.
5. Complete recording within 5 minutes.
6. Press the EDIT/NO button and stop recording .
7. Press the EJECT button and remove the MO disc.
The above has been how to create a continuous recording data
for the focus bias adjustment and error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
laser tap
Optical pickup flexible board
— 40 —
4-5. Temperature Compensation Offset Adjustment
Save the temperature data at that time in the non-volatile memory as
25 ˚C reference data.
Note :
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28
˚C. Perform it immediately after the power is turned on when the
internal temperature of the unit is the same as the ambient tem-
perature.
3. When D101 has been replaced, perform this adjustment after the
temperature of this part has become the ambient temperature.
Adjusting Method :
1. Rotate the AMS knob and display “TEMP ADJUST”.
2. Press the ENTER/YES button and select the “TEMP ADJUST”
mode.
3. “TEMP = 
” and the current temperature data will be displayed.
4. To save the data, press the ENTER/YES button.
When not saving the data, press the EDIT/NO button.
5. When the ENTER/YES button is pressed, “TEMP = 
 SAVE”
will be displayed for some time, followed by “TEMP ADJUST”.
When the EDIT/NO button is pressed, “TEMP ADJUST” will be
displayed.
Specifications :
The “TEMP =  
” should be within “E0 - EF”, “F0 - FF”, “00 - 0F”,
“10 - 1F” and “20 - 2F”.
4-6. Laser Power Adjustment
Connection :
Adjusting Method :
1. Set the laser power meter on the objective lens of the optical pickup.
(When it cannot be set properly, press the 
0 button or ) but-
ton and move the optical pickup.)
Connect the digital volt meter to TP (IOP) and TP (I+5V).
2. Rotate the AMS knob and display “LDPWRADJUST”.
(Laser power : For adjustment)
3. Press the ENTER/YES button twice and display “LD $ 4B = 3.5
mW”.
4. Adjust RV102 of the BD board so that the reading of the laser
power meter becomes 3.4
 mW.
5. Press the ENTER/YES button and display “LD $ 96 = 7.0 mW”.
(Laser power:MO reading)
6. Check that the laser power meter and digital voltmeter readings
satisfy the specified value.
Specification :
Laser power meter reading : 7.0 ± 0.3 mW
Digital voltmeter reading : Optical pickup displayed value ± 10%
(Optical pickup label)
+0.1
–0
Laser power
meter
Optical pick-up
objective lens
Digital voltmeter
KMS
210A
27X40
B0825
n
lop = 82.5 mA in this case
lop (mA) = Digital voltmeter reading (mV)/ 1 (
)
7. Press the ENTER/YES button and display “LD $ 0F = 0.7 mW”.
(Laser power: MO reading)
8. Check that the laser power meter at this time satisfies the speci-
fied value.
Specification :
Laser power meter reading : 0.70 ± 0.1 mW
9. Press the EDIT/NO button and display “LDPWR ADJUST’, and
stop laser emission.
(The EDIT/NO button is effective at all times to stop the laser
emission.)
BD board
TP (I + 5V)
TP (IOP)
Page of 65
Display

Click on the first or last page to see other MDS-B5 service manuals if exist.