ICD-UX532/UX533/UX533F/UX534F
9
2-6.  ELECTRET  CAP  MICROPHONE  BLOCK (L-ch)
2-7.  MAIN  BOARD
Remove two solders.
electret cap microphone block (L-ch)
MAIN board 
electret cap 
microphone 
block (L-ch) 
blue
white
‡:LUHVHWWLQJ
–)URQWWRSVLGHYLHZ–
Remove two solders.
Remove two solders.
Remove two solders.
sheet 
 (noise 
 control)
connector
MAIN board
battery terminal (
)
battery terminal (
+)
USB flexible board
screw (B1.4)
two screws 
 (B1.4)
(UX533F/
UX534F)
– Front top side view –
Remove the MAIN board 
 
in the direction of an arrow. 
MAIN board 
black
black
red
red
‡ Wire setting
Note 2:  When replacing MAIN board, refer to “ABOUT THE 
DESTINATION SETTING WHEN REPLACING THE 
MAIN BOARD” on page 4.
Note 1:  When the MAIN board is replaced, the setup of LCD 
backlight is required. Perform the setup of LCD back-
light with reference to “4-2. LCD BackLight” (page 13) 
on test mode.
ICD-UX532/UX533/UX533F/UX534F
10
2-9.  USB  ASSY (USB1)
2-8.  ELECTRET  CAP  MICROPHONE  BLOCK (R-ch)
electret cap 
microphone 
block (R-ch) 
loudspeaker (2.0 cm)
boss
claw
electret cap 
 microphone 
 block 
(R-ch)
‡:LUHVHWWLQJ
–6HFWLRQDOYLHZ–
speaker wire
microphone wire
claw
boss
–)URQWWRSVLGHYLHZ–
1 screw
 (M1.4)
4 knob (USB)
2 claw
5 USB assy (USB1)
shaft
hole
Note: When installing USB assy, align the shaft of  
 
USB assy and the hole of knob (USB). 
– Front top side view –
Remove the USB assy
 
in the direction of an arrow. 
ICD-UX532/UX533/UX533F/UX534F
11
2-10.  SLOT  BOARD
1 two claws
2 SLOT board
– Front top side view –
ICD-UX532/UX533/UX533F/UX534F
12
SECTION  3
TEST  MODE
1.  SETTING  THE  TEST  MODE
Note: Test mode is impossible when battery voltage is not enough.
 
  Do work using the battery with suffi cient battery level.
Setting method:
1.  Equip this unit with battery.
2.  Slide the [HOLD•POWER] switch in the direction of “POW-
ER” until the window display appears.
HOLD
POWER
3.  Slide the [DPC (SPEED CTRL)] switch to OFF.
DPC (SPEED CTRL) OFF
ON
4.  While pressing the [STOP/
x
] and [VOL –] keys, slide the 
[DPC (SPEED CTRL)] switch to ON.
DPC (SPEED CTRL) OFF
ON
STOP/x
VOL –
5.  The test mode menu is displayed, and enter the test mode. Re-
lease the [STOP/
x
] and [VOL –] keys.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<SERVICE MENU>
ICD-UX532/CN
1.00.01
Destination
Model name
Firmware version
LCD Display
2.  RELEASING  THE  TEST  MODE
Remove battery.
3.  CONFIGURATION  OF  THE  TEST  MODE
[
.
] key
[
>
] key
J
j
k
K
‡
‡
‡
‡
Normal mode
Slide the [DPC (SPEED CTRL)] switch to OFF.
While pressing the [STOP/
x
] and [VOL –] keys, 
slide the [DPC (SPEED CTRL)] switch to ON.
Release the [STOP/
x
] and [VOL –] keys.
Remove battery.
Initial state of test mode
End of test mode
Determine
using
[
N
]
key
Return using
[STOP/
x
] key
SERVICE MENU
VERSION
LCD BackLight
KEY CHECK
AUDIO LOOP
LCD BL_Manual
SIN
BEEP
LCD CONT
LCD PATTERN
RTC TEST
BATT A/D
ZLOAD
LOW DET
VBUS
FM TEST
KEY COUNT
SLEEP
BATT LIFE
WRITER VER
CHG LOG
LREC LOG
LREC LOG Clear
MENU INIT
SERVICE MENU
Page of 26