ICD-UX532/UX533/UX533F/UX534F
5
SECTION  2
DISASSEMBLY
• 
This set can be disassembled in the order shown below.
2-1.  DISASSEMBLY  FLOW
SET
2-2. CASE 
(F) 
ASSY
 (Page 
6)
2-3. SWITCH 
BOARD
 (Page 
7)
2-5.  LCD UNIT (LCD501)
 (Page 
8)
2-6.  ELECTRET CAP MICROPHONE 
 BLOCK 
(L-ch)
 (Page 
9)
2-8.  ELECTRET CAP MICROPHONE 
 BLOCK 
(R-ch)
 (Page 
10)
2-4. CHASSIS
 (Page 
8)
2-7. MAIN 
BOARD
 (Page 
9)
2-9. USB 
ASSY 
(USB1)
 (Page 
10)
2-10. SLOT BOARD
 (Page 
11)
ICD-UX532/UX533/UX533F/UX534F
6
Note: Follow the disassembly procedure in the numerical order given.
2-2.  CASE (F)  ASSY
0 Insert the jig in the space between the case 
 
(F) assy and the case (R) assy and remove.
screw
 (PTP1.4)
tapping screw
 (M1.4 
u 3)
Open the battery case lid.
two claws
knob
switch
switch
switch
two claws
qa 
three
 claws
qa 
two claws
qa 
four claws
qa 
claw
six claws
– Rear top side view –
– Front top side view –
knob (power)
foot (case)
knob (DPC)
Note: When installing each knob, match the 
 
position of switches and each knob.
qs Remove all claws while rounding in outer.
qd case (F) assy
‡
 JIG
  When disassembling the unit, use the following jig.
 Part No. 
Description
  9-913-402-33  Tool for Disassembling
ICD-UX532/UX533/UX533F/UX534F
7
2-3.  SWITCH  BOARD
claw
claw
– Front top side view –
SWITCH board
Turn the SWITCH board 
 
in the direction of an arrow. 
USB flexible board
 (CN451)
Remove the SWITCH board in the direction of an arrow.
Note 1: When installing the SWITCH board, 
 
align the hole with the boss.
Note 2: When you install the flexible board, 
 
please install them correctly.
 
There is a possibility that this machine 
 
damages when not correctly installing it.
Insert is straight to the interior.
Insert is incline
flexible board
connector
OK
NG
flexible board
connector
ICD-UX532/UX533/UX533F/UX534F
8
2-5.  LCD  UNIT (LCD501)
2-4. CHASSIS
Slide the knob (USB).
claw
boss
claw
boss
claw
chassis
– Front top side view –
Note: When installing the chassis, align 
 
two holes and two bosses. 
claw
LCD flexible board
claw
claw
claw
claw
claw
LCD unit
 (LCD501)
cushion (LCD)
– Front top side view –
Remove the LCD unit in the 
 
direction of an arrow. 
Note 1: When installing,
 
the LCD unit, align
 
the hole with
 the 
boss.
Note 2: When you install the flexible 
 
board, please install them 
 
correctly. There is a possibility 
 
that this machine damages 
 
when not correctly installing it.
Insert is straight to the interior.
Insert is incline
flexible board
connector
OK
NG
flexible board
connector
Note 3:  When the LCD unit (LCD501) is replaced, 
the setup of LCD backlight is required. 
Perform the setup of LCD backlight with 
reference to “4-2. LCD BackLight” (page 
13) on test mode.