Sony ICD-UX532 / ICD-UX533 / ICD-UX533F / ICD-UX534F Service Manual ▷ View online
ICD-UX532/UX533/UX533F/UX534F
17
4-12. ZLOAD
The battery load check can be operated compulsorily.
The battery load check can be operated compulsorily.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “ZLOAD”, and
press the [
N
] key.
3. ON/OFF of ZLOAD is changed.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
ZLOAD : ON
<ZLOAD>
LCD Display
Key input settings under this mode of operation:
[
>
] or [
.
] : ON/OFF of ZLOAD change
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-13. LOW
DET
LOWBATT_XDET (Battery voltage decrease detection signal)
can be checked.
can be checked.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “LOW DET”, and
press the [
N
] key.
3. The state of LOW DET is displayed.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
LOW DET : OFF
<LOW DET>
LCD Display
OFF : LOWBATT_XDET=1 (H)
ON : LOWBATT_XDET=0 (L)
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-14. VBUS
VBUS detection signal can be checked.
VBUS detection signal can be checked.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “VBUS”, and press
the [
N
] key.
3. The state of VBUS_XDET is displayed.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
OFF
<VBUS>
LCD Display
OFF
:
VBUS_XDET=1
(H)
ON
:
VBUS_XDET=0
(L)
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-15. FM TEST (ICD-UX533F/UX534F only)
FM tuner can be checked.
FM tuner can be checked.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “FM TEST”, and
press the [
N
] key.
3. The state of FM tuner is displayed.
FM : OK DX
80.00 Lv: 5A
CH: 80.00
80.00 Lv: 5A
CH: 80.00
<FM TEST>
LCD Display
OK : ID acquisition value OK
NG : ID acquisition value NG
In OK, it becomes FM receiving mode.
Key input settings under this mode of operation:
[.] : Receiving step value decrease
[>] : Receiving step value increase
[
N
]
: Receiving sensitivity change (DX ↔ LOCAL)
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
ICD-UX532/UX533/UX533F/UX534F
18
4-16. KEY
COUNT
The count value of the keys and switches operation can be dis-
played. However, distinction of kind of the keys and switches
which operated is not performed.
played. However, distinction of kind of the keys and switches
which operated is not performed.
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “KEY COUNT”,
and press the [
N
] key.
3. The count value of the keys and switches operation is dis-
played.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
00888
<KEY COUNT>
LCD Display
Count value increase conditions:
One of buttons is pushed.
One of switches is slid.
Headphone or microphone is inserted.
Releasing method:
Remove battery.
Remove battery.
4-17. SLEEP
It can change into the sleep state for standby current value mea-
surement.
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “SLEEP”, and press
the [
N
] key.
3. The sleep state selection screen is displayed.
This unit shifts to the sleep state by pressing the [
N
] key
again.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
SLEEP:NORMAL
Excuting...
Excuting...
<SLEEP>
LCD Display
Releasing method:
Remove battery.
Remove battery.
4-18. BATT
LIFE
Not used for the servicing.
4-19. WRITER
VER
Not used for the servicing.
4-20. CHG
LOG
The charge log saved at SRAM can be copied to eMMC.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “CHG LOG”, and
press the [
N
] key.
3. The charge log saved at SRAM is copied to eMMC.
Success
<CHG LOG>
LCD Display
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-21. LREC
LOG
Not used for the servicing.
4-22. LREC LOG Clear
Not used for the servicing.
Not used for the servicing.
4-23. MENU
INIT
This unit can return to the factory shipment settings.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “MENU INIT”, and
press the [
N
] key.
3. Initialization is performed.
Formatting...
<MENU INIT>
LCD Display
4. “Success” is displayed, and this unit reboots.
Success
LCD Display
19
ICD-UX532/UX533/UX533F/UX534F
SECTION 4
EXPLODED VIEWS
1
4-290-103-01 FOOT (CASE) (for SILVER)
1
4-290-103-11 FOOT (CASE) (for PINK)
1
4-290-103-51 FOOT (CASE) (for CHAMPAGNE GOLD)
1
4-290-103-61 FOOT (CASE) (for BLACK)
1
4-290-103-81 FOOT (CASE) (for BLUE)
2
4-290-187-03 KNOB (DPC) (for SILVER)
2
4-290-187-63 KNOB (DPC) (for BLACK)
2
4-436-312-01 KNOB (DPC) (for PINK)
2
4-436-312-11 KNOB (DPC) (for BLUE)
2
4-436-312-21 KNOB (DPC) (for CHAMPAGNE GOLD)
3
4-290-102-02 KNOB (POWER) (for SILVER)
3
4-290-102-62 KNOB (POWER) (for BLACK)
3
4-436-311-02 KNOB (POWER) (for PINK)
3
4-436-311-12 KNOB (POWER) (for BLUE)
3
4-436-311-22 KNOB (POWER) (for CHAMPAGNE GOLD)
Ref. No.
Part No.
Description
Remark
Ref. No.
Part No.
Description
Remark
Note:
• -XX and -X mean standardized parts, so
• -XX and -X mean standardized parts, so
they may have some difference from the
original one.
original one.
• Items marked “*” are not stocked since
they are seldom required for routine ser-
vice. Some delay should be anticipated
when ordering these items.
vice. Some delay should be anticipated
when ordering these items.
• The mechanical parts with no reference
number in the exploded views are not sup-
plied.
plied.
• Color Indication of Appearance Parts Ex-
ample:
KNOB, BALANCE (WHITE) . . . (RED)
Parts Color Cabinet’s Color
4-1. OVERALL SECTION
• Rear side view
• Abbreviation
CH
CH
: Chinese model
CND : Canadian model
KR
KR
: Korean model
LA
: Latin American model
• Refer to “COLOR VARIATION” in the
“SERVICING NOTES” (page 3) about col-
or variation of model and destination.
or variation of model and destination.
front case section
1
2
3
Ver. 1.1
20
ICD-UX532/UX533/UX533F/UX534F
4-2. FRONT CASE SECTION
• Rear side view
51
3-348-998-41 SCREW (M1.4X3), TAPPING, PAN
52
3-252-824-01 SCREW +PTP 1.4
53
A-1897-722-A CASE (FSE) ASSY (for SILVER) (UX532/UX533)
53
A-1897-782-A CASE (FNEF) ASSY (for CHAMPAGNE GOLD)
(UX533F/UX534F)
53
A-1897-796-A CASE (FSEF) ASSY (for SILVER) (UX533F)
53
A-1897-817-A CASE (FBEF) ASSY (for BLACK)
(UX533F/UX534F)
53
A-1897-844-A CASE (FPEF) ASSY (for PINK) (UX533F)
53
A-1897-850-A CASE (FLEF) ASSY (for BLUE) (UX533F)
53
A-1921-931-A CASE (FBE) ASSY (for BLACK) (UX532/UX533)
53
A-1922-004-A CASE (FNE) ASSY (for CHAMPAGNE GOLD)
(UX533)
53
A-1922-007-A CASE (FLE) ASSY (for BLUE) (UX533)
54
4-290-101-01 BUTTON (SIDE) (–, +,
) (for SILVER)
54
4-290-101-61 BUTTON (SIDE) (–, +,
) (for BLACK)
54
4-436-310-01 BUTTON (SIDE) (–, +,
) (for PINK)
54
4-436-310-11 BUTTON (SIDE) (–, +,
) (for BLUE)
54
4-436-310-21 BUTTON (SIDE) (–, +,
)
(for CHAMPAGNE GOLD)
55
4-436-307-01 BUTTON
(FRONT)
(s, z, f, l, H, L, F) (for SILVER)
55
4-436-307-11 BUTTON
(FRONT)
(s, z, f, l, H, L, F) (for PINK)
55
4-436-307-21 BUTTON
(FRONT)
(s, z, f, l, H, L, F) (for BLUE)
55
4-436-307-31 BUTTON
(FRONT)
(s, z, f, l, H, L, F)
(for CHAMPAGNE GOLD)
55
4-436-307-41 BUTTON
(FRONT)
(s, z, f, l, H, L, F) (for BLACK)
Ref. No.
Part No.
Description
Remark
Ref. No.
Part No.
Description
Remark
LCD section
52
53
55
54
51
Ver. 1.1
Click on the first or last page to see other ICD-UX532 / ICD-UX533 / ICD-UX533F / ICD-UX534F service manuals if exist.