ICD-UX522/UX522F/UX523/UX523F
5
Note: Follow the disassembly procedure in the numerical order given.
2-2. CASE (F) ASSY
0 Insert the jig in the space between the case
(F) assy and the case (R) assy and remove.
7
screw
(PTP1.4)
9
screw
8
Open the battery case lid.
1
two claws
3
two claws
2
knob (DPC)
knob
switch
switch
switch
switch
1
two claws
qa
two claws
qa
two claws
qa
four claws
qa
claw
5
six claws
– Rear top view –
– Front top view –
4
knob (power)
6
foot (case)
2
knob (DPC)
Note: When installing each knob, match the
position of switches and each knob.
qs Remove all claws while rounding in outer.
qd case (F) assy
JIG
When disassembling the set, use the following jig.
Part No.
Description
9-913-402-33 Tool for Disassembly
ICD-UX522/UX522F/UX523/UX523F
6
2-4. HOLDER (LCD) BLOCK
2-3. SWITCH BOARD
1
claw
rib
4
USB flexible board
USB flexible board
upper side
lower side
5
SWITCH board
3
Lift up the
SWITCH
board.
SWITCH board
rib of chassis
2
claw
– Front top view –
– Right side view –
USB flexible board setting
4
claw
6
LCD flexible board
1
Peel off the sheet (copper leaf).
3
sheet (copper leaf)
2
Remove the solder.
4
claw
– Front top view –
7
holder (LCD) block
5
Lift up the holder (LCD) block.
ICD-UX522/UX522F/UX523/UX523F
7
2-6. LED BOARD
2-5. LIQUID CRYSTAL DISPLAY PANEL (LCD501)
2
claw
2
two claws
4
reflection sheet
5
light guide plate
6
liquid crystal display panel
(LCD501)
1
cushion (LCD)
3
– Front top view –
2
Peel off the LED
board from adhesive
sheet (cover jog).
1
Remove two
solders.
4
Remove two solders.
5
two lead wire
7
LED board
6
insulating sheet (XTAL)
– Front top view –
– LED board –
– MAIN board, LED board –
LED board
MAIN board
black
red
black
red
Wire setting
3
Lift up the
LCD
board.
ICD-UX522/UX522F/UX523/UX523F
8
2-8. ELECTRET CAP MICROPHONE BLOCK (L)
2-7. CHASSIS BLOCK
3
chassis block
1
Slide the knob (USB).
2
claw
– Front top view –
2
claw
1
Remove two
solders.
2
electret cap microphone block (L)
– Front top view –
MAIN board
electret cap
microphone
block (L)
microphone
block (L)
blue
white
Wire setting
Click on the first or last page to see other ICD-UX522 / ICD-UX522F / ICD-UX523 / ICD-UX523F service manuals if exist.