Sony ICD-UX522 / ICD-UX522F / ICD-UX523 / ICD-UX523F Service Manual ▷ View online
ICD-UX522/UX522F/UX523/UX523F
13
4-4. SIN
Sine wave can be outputted.
Sine wave can be outputted.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “SIN”, and press
the [
N
/ENTER] key.
3. Sine wave is outputted.
<SIN>
Vol:10
LCD Display
*Displayed characters/values are example.
Initial value:
Play back volume : 10 (stereo)
fs
:
44.1kHz
Sound is outputted from the D-AMP built-in CPU at the time
of headphone wearing.
of headphone wearing.
Key input settings under this mode of operation:
[VOL +] : Volume up
[VOL –] : Volume down
Operation of others by the plug/unplug signal (the external micro-
phone jack and headphone jack) are based on operation of this unit.
phone jack and headphone jack) are based on operation of this unit.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-5. BEEP
Beep sound (1.3 kHz) can be outputted.
Beep sound (1.3 kHz) can be outputted.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “BEEP”, and press
the [
N
/ENTER] key.
3. Beep sound (1.3 kHz) is outputted.
<BEEP>
1.3KHz ON
Vol:10
1.3KHz ON
Vol:10
LCD Display
*Displayed characters/values are example.
Key input settings under this mode of operation:
[VOL +] : Volume up
[VOL –] : Volume down
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-6. LCD CONT
LCD contrast can be adjusted.
LCD contrast can be adjusted.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “LCD CONT”, and
press the [
N
/ENTER] key.
3. Adjustment of LCD contrast becomes available.
<LCD CONT>
Vol: 16
[FF]+ [FR]
Vol: 16
[FF]+ [FR]
[PLAY] Save
LCD Display
*Displayed characters/values are example.
Initial value:
The default setting saved at eMMC.
Key input settings under this mode of operation:
[.]
: Contrast value decrease
[>]
: Contrast value increase
[
N
/ENTER] : The current contrast value is written to eMMC.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-7. LCD PATTERN
The check of LCD dead pixel is made.
The check of LCD dead pixel is made.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “LCD PATTERN”,
and press the [
N
/ENTER] key.
3. LCD display pattern is displayed as shown in the following
fi gure.
LCD Display Pattern
All segments ON
All segments OFF
Partial segments ON
Key input settings under this mode of operation:
[
>
] or [
.
] : Display pattern change
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
ICD-UX522/UX522F/UX523/UX523F
14
4-8. RTC TEST
The self-test of RTC module can be done.
The self-test of RTC module can be done.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “RTC TEST”, and
press the [
N
/ENTER] key.
3. The self-test of RTC module is executed, and result is dis-
played.
<RTC TEST>
OK
OK
LCD Display
*Displayed characters/values are example.
RTC self-test result
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-9. BATT A/D
A/D value (voltage value and temperature value) acquisition can
be performed.
A/D value (voltage value and temperature value) acquisition can
be performed.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “BATT A/D”, and
press the [
N
/ENTER] key.
3. A/D value (voltage value and temperature value) are acquired,
and they are displayed.
(8 bit (The bit shift after LSB side 2 bit omission))
Displayed values are always updated.
<BATT A/D>
AC: 7B 2AC: 00
BC: 7B 4BC: 00
TEMP: 6F
AC: 7B 2AC: 00
BC: 7B 4BC: 00
TEMP: 6F
LCD Display
*Displayed characters/values are example.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-10. ZLOAD
Compulsive operation of a battery load check can be performed.
Compulsive operation of a battery load check can be performed.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “ZLOAD”, and
press the [
N
/ENTER] key.
3. ON/OFF of ZLOAD is changed.
<ZLOAD>
ZLOAD : OFF
ZLOAD : OFF
LCD Display
*Displayed characters/values are example.
Key input settings under this mode of operation:
[
>
] or [
.
] : ZLOAD change (ON ↔ OFF)
[
N
/ENTER]
: ZLOAD_CTL change (H ↔ L)
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-11. LOW
DET
LOWBATT_XDET (Battery voltage decrease detection signal)
can be checked.
can be checked.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “LOW DET”, and
press the [
N
/ENTER] key.
3. The state of LOW DET is displayed.
<LOW DET>
LOW DET: OFF
LOW DET: OFF
LCD Display
*Displayed characters/values are example.
OFF : LOWBATT_XDET=1 (H)
ON : LOWBATT_XDET=0 (L)
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
ICD-UX522/UX522F/UX523/UX523F
15
4-12. VBUS
VBUS detection signal can be checked.
VBUS detection signal can be checked.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “VBUS”, and press
the [
N
/ENTER] key.
3. The state of VBUS_XDET is displayed.
<VBUS>
OFF
OFF
LCD Display
*Displayed characters/values are example.
OFF
:
VBUS_XDET=1
(H)
ON
:
VBUS_XDET=0
(L)
Key input settings under this mode of operation:
[
N
/ENTER] : It shifts to the suspension state.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-13. FM TEST (ICD-UX522F/UX523F only)
FM tuner can be checked.
FM tuner can be checked.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “FM TEST”, and
press the [
N
/ENTER] key.
3. The state of FM tuner is displayed.
<FM TEST>
FM: OK DX
80.00 Lv: 5A
CH: 80.00
FM: OK DX
80.00 Lv: 5A
CH: 80.00
LCD Display
*Displayed characters/values are example.
OK : ID acquisition value OK
NG : ID acquisition value NG
In OK, it becomes FM receiving mode.
Key input settings under this mode of operation:
[.]
: Receiving step value decrease
[>]
: Receiving step value increase
[
N
/ENTER] : Receiving sensitivity change (DX ↔ LOCAL)
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-14. KEY
COUNT
The count value of the keys and switches operation can be dis-
played. Distinction of the keys and switches which operated is not
performed.
played. Distinction of the keys and switches which operated is not
performed.
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “KEY COUNT”,
and press the [
N
/ENTER] key.
3. The count value of the keys and switches operation is dis-
played.
<KEY COUNT>
00888
00888
LCD Display
*Displayed characters/values are example.
Count value increase conditions:
One of buttons is pushed.
One of switches is slid.
micro SD card is inserted.
Headphone or microphone is inserted.
Releasing method:
Remove battery.
Remove battery.
4-15. SLEEP
It can change into the sleep state for standby current value mea-
surement.
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “SLEEP”, and press
the [
N
/ENTER] key.
3. The sleep state selection screen is displayed.
This unit shifts to the sleep state by pressing the [
N
/ENTER]
key again.
<SLEEP>
SLEEP:NORMAL
Excuting...
SLEEP:NORMAL
Excuting...
LCD Display
*Displayed characters/values are example.
Releasing method:
Remove battery.
Remove battery.
Ver. 1.1
ICD-UX522/UX522F/UX523/UX523F
16
4-16. BATT
LIFE
The result measured with the battery life measurement fi rmware
can be displayed.
can be displayed.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “BATT LIFE”, and
press the [
N
/ENTER] key.
3. The result measured with the battery life measurement fi rm-
ware is displayed.
<BATT LIFE>
- - - - REC 0 Lv1
YY/MM/DD
HH/MM/SS
- - - - REC 0 Lv1
YY/MM/DD
HH/MM/SS
LCD Display
*Displayed characters/values are example.
Hours/minutes/seconds
Year/months/days
Recording mode/
Recording and
playback type/
Battery level
Recording and
playback type/
Battery level
Recording mode:
Recording mode of the fi le recorded or played back at the time
of measurement is displayed.
of measurement is displayed.
(192/128/M160/M48/M8/LPCM/FM/FMREC/ST/STSP/
STLP/SP/LP etc.)
Recording and play back type:
The state at the time of measurement is displayed.
Battery level:
The battery life value is displayed. Value is changed by press-
ing the [
ing the [
>
] or [
.
] keys.
Battery
lebel:
LV1= 100%
LV2= 50%
LV3= 25%
LV4= >25%
LV5= 0%
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-17. WRITER
VER
Not used for the servicing.
4-18. CHG
LOG
The charge log saved at SRAM can be copied to eMMC.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[
>
] or [
.
] keys to select the “CHG LOG”, and
press the [
N
/ENTER] key.
3. The charge log saved at SRAM is copied to eMMC.
<CHG LOG>
Success
Success
LCD Display
*Displayed characters/values are example.
Result Indication
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-19. LREC
LOG
Not used for the servicing.
4-20. LREC LOG Clear
Not used for the servicing.
Not used for the servicing.
4-21. MENU
INIT
This unit can return to the factory shipment settings.
Procedure:
1. Enter the test mode.
2. Press the [
1. Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “MENU INIT”, and
press the [
N
/ENTER] key.
3. Initialization is performed.
“Success” is displayed, and this unit reboots.