9
ICD-SX46/SX56/SX66
SECTION 3
TEST  MODE
[Setting Method of the Test Mode]
To enter the test mode, turn on the  HOLD .  switch while press-
ing the  x  key and  VOL+  key at the same time with the power on.
[Exiting Method of the Test Mode]
Exit the test mode by turning off the power.
[Initial Status of the Test Mode]
When the test mode is set, the LCD display appears as shown below.
LCD display (Example)
[Flow Chart of the Test Mode]
START
>
.
.
.
>
>
.
Initial status of test mode 
Model code, LPEC ST, 
F/W version display
TEST MODE
END
TEST MODE
Turn off the power
(Extract the batteries or DC jack)
>
USB
KEY COUNT
RESET MENU
LED
B A T T
KEY
LCD
AUDIO
SLEEP
BEEP
RTC
>
>
>
>
.
.
.
.
>
>
>
>
.
.
.
.
[Operation in the Test Mode]
After entering the test mode, you can move within the test menu by
pressing the .  /  >  key. You can move to the submenu by
pressing the x
B key. Then each test mode can be executed.
1. LCD test
• LCD is tested of all light-on and all light-off.
2. Audio test
Perform the through-playback and sine wave output.
• Contents of the submenu
DSP ST: DSP STEREO through mode
DSP MO: DSP MONO through mode
SIN: 1 kHz sine wave output mode
•  Select the microphone sensitivity with the  A-B 
   switch.
HtMtLtHtMt ...
• The VOR detection operation can be checked by the LED.
Sound : The red LED is turned on. No sound: The red LED
      is turned off.
• MUTE can be set to “ON” or “OFF” with the  ERASE  key.
• The sound volume can be adjusted with the  VOL+  key or  VOL–
key during the audio test except the MUTE mode.
   
In the directional microphone selection, ON/OFF of the DI-
RECTNL switch is performed with the  DIVIDE  key.
   
 
DIRECTNL switch ON : The green LED is turned on.
                                  
 
OFF : The green LED is turned off.
• In the audio test mode the operation is performed according to
JACK detection.
• The microphone sensitivity, sound volume and MUTE (on/off)
are displayed on the LCD.
• The microphone sensitivity selection and the VOR test are ef-
fective in the through-playback mode.
• The directional microphone selection is effective in the DSP
MONO through mode.
6d
01
b110
-56
6d
01 b110-56
Iris(DSP) version : 6d
LPEC ST version : 01
SakuraR(CPU) version : 1.10
(In 
α
 version or 
β
 version, A or B is displayed)
Model code : SX56
x
B
.
>
LCD OFF
LCD CHK
LCD ALL
:
:
LCD ALL
CHK START
CHK END 
LCD
x
x
x
x
B
A
D
C
E
REC
STLPSP
L
H
YH
88
8888 888888
MM
DS
m
(LCD off)
.
>
(select),
(set)
x
B
x
B
:
:
DSP MONO
SIN WAVE
DSP ST
AUDIO  
DSP ST 
oFDSP ST12
oFSIN WAV06
x
x
x
H
m
oFDSP M 23
L
m
DSP STEREO through mode / MIC : M / MUTE : ON / VOL-LEVEL : 12
t
 "M / on / 12 / DSP ST"
DSP MONO through mode / MIC : H / MUTE : OFF / VOL-LEVEL : 23
t
 "H / oF / 23 / DSP MO"
1k sine wave output mode / MUTE : ON / VOL-LEVEL : 06 t "on / 06 / SIN"
.
>
(select),
(set)
x
B
10
ICD-SX46/SX56/SX66
3. Sleep test
• Pressing the  x
B  key causes the set to enter the sleep state.
• When the  HOLD .  switch is ON, the LCD is turned off.
When OFF, the LCD is turned on.
• Press any keys to exit the sleep state.
4. Beep test
• Beep sound of 1.3 kHz or 2 kHz is output.
5. RTC test
• Perform the function test of the RTC and EEPROM.
(1) RTC EEPROM test
Confirmation of writing, reading (verifying) and erasing of
arbitrary data with the specified registers.
(2) RTC clock function test
Confirmation that RTC updates the time to the microcomputer
at one second interval.
• OK, NG judgement is performed to the test result.
When NG, it is displayed which device RTC or EEPROM
becomes NG.
    (All OK : “RTC OK” / RTC NG : “RTC BAD” / EEPROM NG
: “EEP BAD”)
6. Key entry test
• When the any key is pressed, the entry key and the A/D con-
verted value (hexadecimal) of the two channel keys are dis-
played.
• When the x key is pressed, the A/D value of the key is dis-
played while the key is depressed. When the key is released, the
screen returns to the test menu.
7. Battery remaining power and DC IN test
• The detected A/D value (hexadecimal) of the battery remaining
power is displayed. When DC jack is inserted, the battery mark
on the LCD is turned off.
any keys
any keys
(LCD OFF)
(with HOLD 
.
OFF status)
x
B
(with HOLD 
.
ON status)
x
B
SLEEP SOON
SLEEP IN 
SLEEP  
x
B
RTC  
RTC OK
x
bATT FF
bATT C2
x
B
DC jack
is inserted
DC jack
is extracted
B A T T
bATT FF
x
x
B
KEY oFFiFF
KEY   
x
8. LED test
• LEDs (OPR: red and green) are all turned on.
9. USB test
• When the menu starts the USB self-check, either presence or
absence of the Vbus is judged.
(Vbus is present: “ON VBUS”, Vbus is absent: “OFF VBUS”)
• The USB driver always works regardless of presence or ab-
sence of the USB signal only when Vbus is available during the
USB test. At this time, turning on  HOLD .  causes the set
to move to the suspend state. Turning off the Vbus causes the
set to return to the test menu.
• In the menumode if the Vbus is supplied, any key will not work.
Therefore the Vbus will be supplied after surely pressing the
 x
B  key.
10. Key durable test
• Pressing the  x
B  key makes the count to “------” and sets test
standby status.
Once more pressing the  x
B   key makes the count to “000000”
and sets the key durable test.
In this mode any key input and slide switch operation are counted
and the number is displayed.
Turn off the power to exit this mode.
11. Menu reset
• Pressing the  x
B  key causes the set to enter the menu initial-
ization standby state.
• When the following keys are all entered, the EEPROM initial-
ization (returning setting in the menu and user name to default
value) and formatting process (deleting all message files in the
flash memory) are executed. At the same time, the WakeUp
signal is checked, too.
      Check keys: VOL– ,    VOL+ ,   A-B 
 ,   ERASE ,
DIVIDE ,   DPC  ON,   DPC  OFF,   . ,
x•B ,   > ,   FOLDER ,   MENU ,   x ,
z REC ,   HOLD . ON,   HOLD .  OFF,
DIRECTNL  ON, and   DIRECTNL  OFF,
VOICE UP  ON,  and   VOICE UP  OFF
x
B
LED ON
LED   
x
LED ON (orange)
LED OFF
x
B
ON 
cut Vbus
Vbus
on
cut Vbus
Suspend 
mode
HOLD 
.
SUSPEND
VBUS ON
VBUS OFF
USB  
x
x
B
x
B
any keys or slide
switches operation
KEY 000001
KEY 000000
KEY-----
KEY COUNT
x
Key durable
test
x
B
BEEP 2.0K
BEEP 1.3K
:
:
BEEP1.3K
  BEEP1.3K
 BEEP 2.0K
BEEP  
x
x
x
.
>
(select),
(set)
x
B
11
ICD-SX46/SX56/SX66
x
B
In the case that
the initialization
and reset operation
end correctly.
(0.5 sec. blinking) 
All keys 
are entered
ALL OK 
INIT
KEY PUSH 
RESET MENU
x
• If all tests end in success, “ALL OK” is displayed. If initializa-
tion in the EEPROM is NG, “INIT. NG” appears.
• Turn off the power to exit the test mode.
12
ICD-SX46/SX56/SX66
SECTION 4
DIAGRAMS
• Waveform
Note on Schematic Diagrams:
• All capacitors are in 
µ
F unless otherwise noted.  (p: pF) 50 WV or
less are not indicated except for electrolytics and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise specified.
•        
f
: internal tolerance.
C
: panel designation.
A
: B+ Line.
• Power voltage is dc 3V and fed with regulated dc power supply
from DC IN jack (J5001).
• Voltages and waveforms are dc with respect to ground under no-
signal (detuned) conditions.
no mark : PLAY
[           ]
  
: REC
      ∗
  
: Impossible to measure
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal production toler-
ances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal production toler-
ances.
• Circled numbers refer to waveforms.
• Signal path.
F
: PB
L
: REC
*
Replacement of IC6001 and IC7003 used in this set requires a
special tool.
• The voltage and waveform of CSP (chip size package) cannot be
measured, because its lead layout is different from that of conven-
tional IC.
Note on Printed Wiring Boards:
Y
: parts extracted from the conductor side.
: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
*
Replacement of IC6001 and IC7003 used in this set requires a
special tool.
• Lead layouts
Lead layout of
conventional IC
CSP (chip size package)
Caution:
Pattern face side:
Parts on the pattern face side seen from
(Side B)
the pattern face are indicated.
Parts face side:
Parts on the parts face side seen from
(Side A)
the parts face are indicated.
surface
1
 
IC7003 
<z/,
  (XTAL)
1 V/DIV, 100 ns/DIV
3.2 Vp-p
244 ns
Page of 39