ICD-PX333/PX333D/PX333F/PX333M
5
SECTION 2
DISASSEMBLY
•
This set can be disassembled in the order shown below.
2-1. DISASSEMBLY FLOW
SET
2-2. CASE
(FRONT)
ASSY
(Page
6)
2-4. MAIN BOARD BLOCK
(Page
(Page
8)
2-6. LCD
HOLDER
(Page
9)
2-5. SPEAKER
(SP1)
(Page
9)
2-7. ELECTRET CAP MICROPHONE (MIC1),
MAIN
MAIN
BOARD
(Page
10)
2-3. LCD
ASSY
(LCD1)
(Page
7)
ICD-PX333/PX333D/PX333F/PX333M
6
Note: Follow the disassembly procedure in the numerical order given.
2-2. CASE (FRONT) ASSY
3 Insert the jig in the space between the case
(F) assy and the case (R) assy and remove.
2
two screws
1
Open the battery case lid.
4
five claws
4
claw
4
two claws
4
four claws
– Rear bottom view –
– Front top view –
– Front view –
5 Remove all claws while rounding in outer.
9 case (front) assy
JIG
When disassembling the unit, use the following jig.
When disassembling the unit, use the following jig.
Part No.
Description
9-913-402-33 Tool for Disassembling
Speaker wire setting
MAIN board
[red]
[black]
claw
ditch
7
Remove two
solders.
8
Remove two speaker
wires from the claw.
6
Remove the case (front) assy
in the direction of an arrow.
Bottom
side
side
Upper
side
side
ICD-PX333/PX333D/PX333F/PX333M
7
2-3. LCD ASSY (LCD1)
– Front top view –
2
Remove the LCD
block in the direction
of an arrow.
LCD assy
(LCD1)
(LCD1)
guide line
guide line
(center position of LCD assy)
(center position of LCD assy)
sheet (copper leaf)
1
Peel off the adhesive sheet.
7
LCD assy
(LCD1)
6
sheet (copper leaf)
5
sheet (insulating) (B)
sheet (insulating) (B)
3
Remove the solder.
Connector (CN451) is locked.
LCD assy (LCD1)
Connector (CN451) is not locked.
4
LCD flexible board
(CN451)
OK
NG
Note: When installing the LCD flexible board,
check that the connector is locked surely.
LCD assy (LCD1)
Sheet setting
ICD-PX333/PX333D/PX333F/PX333M
8
5 MAIN board block
– Front top view –
– Front view –
2 screw
2 two screws
knob
(power)
(power)
knob
(noise cut)
(noise cut)
S941
S401
1
Remove two solders.
Note 1: When installing the MAIN board
block, match the position of S401
and knob (noise cut).
Note 2: When installing the MAIN board
block, match the position of S941
and knob (power).
3
Remove the MAIN (board) block
in the direction of an arrow.
4
Remove the electret cap
microphone
(MIC1).
electret cap microphone (MIC1)
Electret cap microphone (MIC1) setting
2-4. MAIN BOARD BLOCK
Ver. 1.1
Click on the first or last page to see other ICD-PX333 / ICD-PX333D / ICD-PX333F / ICD-PX333M service manuals if exist.