SECTION 3
TEST MODE
[PANEL TEST MODE]
This mode is used to check the fl uorescent indicator tube, LEDs,
keys, [VOLUME/DJ CONTROL] jog, model, destination and
software version.
This mode is used to check the fl uorescent indicator tube, LEDs,
keys, [VOLUME/DJ CONTROL] jog, model, destination and
software version.
Procedure:
1. Press
[OPTIONS]
*1
/ [X]
*2
button and [FOOTBALL] button
simultaneously and hold 3 seconds.
2. All LEDs and segments in fl uorescent indicator tube are lighted
up. All RGB LEDs are lighted up in white color.
3. When you want to enter to the software version display mode,
press [
+]
*1
/ [PRESET + +]
*2
button.
The model information appears on the fl uorescent indicator
tube.
tube.
Press
[
+]
*1
/ [PRESET + +]
*2
button again to view the
destination information.
4. During the destination information display, press [
+]
*1
/
[PRESET + +]
*2
button. Each time [
+]
*1
/ [PRESET +
+]
*2
button is pressed, the fl uorescent indicator tube
shows the version of each category software in the following
sequence: SC, MTK, OPU, UI, PF, SYS, CD, CDMA, CDMB,
ST, TA, TM and return back to model information display.
sequence: SC, MTK, OPU, UI, PF, SYS, CD, CDMA, CDMB,
ST, TA, TM and return back to model information display.
5. When
[] button is pressed while the version numbers are
being displayed except model and destination, the date of the
software creation appears. When [] button is pressed again,
the display returns to the software version display.
software creation appears. When [] button is pressed again,
the display returns to the software version display.
6. Press
[‒
]
*1
/ [‒ PRESET ‒]
*2
button, the key check mode
is activated.
7. In the key check mode, the fluorescent indicator tube displays
“K 0 V0”.
Each time a button is pressed, “K” value increases. However,
once a button has been pressed, it is no longer taken into
account.
once a button has been pressed, it is no longer taken into
account.
“V” value increases in the manner of 0, 1, 2, 3 ... if
[VOLUME/DJ CONTROL] knob is turned clockwise, or
it decreases in the manner of 0, 9, 8, 7 ... if [VOLUME/DJ
CONTROL] knob is turned counterclockwise.
[VOLUME/DJ CONTROL] knob is turned clockwise, or
it decreases in the manner of 0, 9, 8, 7 ... if [VOLUME/DJ
CONTROL] knob is turned counterclockwise.
8. When [ENTER] button is pressed after all LEDs and segments
in fl uorescent indicator tube light up, alternate segments in
fl uorescent indicator tube and LEDs would light up, all RGB
LEDs would light up in red color. If you press [ENTER]
button again, another half of alternate segments in fl uorescent
indicator tube and LEDs would light up, all RGB LEDs
would light up in green color. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up, all RGB LEDs would light up in blue color.
Pressing [ENTER] button again would turn off all segments in
fl uorescent indicator tube and all LEDs including RGB LEDs.
fl uorescent indicator tube and LEDs would light up, all RGB
LEDs would light up in red color. If you press [ENTER]
button again, another half of alternate segments in fl uorescent
indicator tube and LEDs would light up, all RGB LEDs
would light up in green color. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up, all RGB LEDs would light up in blue color.
Pressing [ENTER] button again would turn off all segments in
fl uorescent indicator tube and all LEDs including RGB LEDs.
9. To release from this mode, press the buttons in the same
manner as step 1, or disconnect the power cord.
[USER RESET]
The user reset clears all data including preset data stored in the data
fl ash to initial conditions exclude history mode data.
The user reset clears all data including preset data stored in the data
fl ash to initial conditions exclude history mode data.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Press
[] button and [LED COLOR] button simultaneously
for 3 seconds.
3. “RESET” appears on the fl uorescent indicator tube. After that,
the fl uorescent indicator tube becomes blank for a while, and
the system is reset.
the system is reset.
Ver. 1.1
Note:
*1
SHAKE33/SHAKE55/SHAKE77 models
*2
SHAKE44/SHAKE66/SHAKE88 models
[COLD RESET]
The cold reset clears all data including preset data stored in the
data fl ash to initial conditions included history mode data. Execute
this mode when returning the set to the customer.
The cold reset clears all data including preset data stored in the
data fl ash to initial conditions included history mode data. Execute
this mode when returning the set to the customer.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Press
[] button and [OPTIONS]
*1
/ [X]
*2
button simultane-
ously for 3 seconds.
3. “COLD RESET” appears on the fl uorescent indicator tube.
After that, the fl uorescent indicator tube becomes blank for a
while, and the system is reset.
while, and the system is reset.
[CD TRAY LOCK MODE]
This mode let you lock the disc tray. When this mode is activated,
the disc tray will not open when [ZOPEN/CLOSE] button is
pressed. The message “LOCKED” will be displayed on the
fl uorescent indicator tube. This mode only applied when there is
disc(s) on the tray.
This mode let you lock the disc tray. When this mode is activated,
the disc tray will not open when [ZOPEN/CLOSE] button is
pressed. The message “LOCKED” will be displayed on the
fl uorescent indicator tube. This mode only applied when there is
disc(s) on the tray.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Select DVD/CD function.
3. Press [] button and [
3. Press [] button and [
+]
*1
/ [PRESET + +]
*2
button simultaneously and hold down until “LOCKED” or
“UNLOCKED” displayed on the fl uorescent indicator tube
(around 5 seconds).
“UNLOCKED” displayed on the fl uorescent indicator tube
(around 5 seconds).
HCD-SHAKE33/SHAKE44/SHAKE55/SHAKE66/SHAKE77/SHAKE88
18
[HISTORY MODE]
This mode is used to check important data stored in the system
when PROTECTOR happen.
This mode is used to check important data stored in the system
when PROTECTOR happen.
Procedure:
1. During demo mode, press [OPTIONS]
*1
/ [X]
*2
button and
[FLANGER] button for 5 seconds to mode into history mode.
2. Press the [TUNING + M >
]
*1
/ [TUNING + >]
*2
button or [TUNING ‒
. m]
*1
/ [TUNING ‒ .]
*2
button to check history data stored.
To release from History Mode.
To release from this mode, press [
To release from this mode, press [
\/1
] button.
Protect Type Description:
Error Code
Description
E01
The over current condition to MOSFET occurs
by defect of MOSFET or defect of PS output
line.
by defect of MOSFET or defect of PS output
line.
E03
Defect of power supply circuit to AMP.
There is possibility of unusual power supply of
any of the AMP IC or Pre-amplifi er.
There is possibility of unusual power supply of
any of the AMP IC or Pre-amplifi er.
E04
DC appears in SP terminal by defect of AMP
IC and MOSFET
or
Defect of DC FAN and DC FAN driver circuit
IC and MOSFET
or
Defect of DC FAN and DC FAN driver circuit
E05
Unusual heat up of MOSFET by improper
assembly of heat sink, destruction of MOSFET
etc.
assembly of heat sink, destruction of MOSFET
etc.
If speaker does not have output even if the set status is not in
PROTECT mode, the following defect might be possible:
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.
Display on fl uorescent indicator tube
Description
P
R
O
C
O
U
N
T
※ ※
No of time protector happen (0 ~ 99)
P
R
O
T
Y
P
E
※ ※ ※ ※
Refer to protect type description
T
1
※ ※ ※ ※ ※
H
※ ※
M
Single Power On Time until protector happened
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
T
2
※ ※ ※ ※ ※
H
※ ※
M
Total Power On Time [ no consider protector happen ]
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
F
U
N
C
※ ※ ※ ※ ※ ※ ※
Input Function during protector happened
V
O
L
※ ※ ※
Volume setting (MIN / 1 - 50 / MAX)
A
T
T
※ ※ ※
Actual attenuation (-87 … 0)
E
Q
L
O
W
※ ※ ※
Low EQ level (-6 … 0 … +6)
E
Q
M
I
D
※ ※ ※
Mid EQ level (-6 … 0 … +6)
E
Q
H
I
G
H
※ ※ ※
High EQ level (-6 … 0 … +6)
S
U
R
R
※ ※ ※
Surround setting (OFF / ON)
D
J
※ ※ ※ ※ ※ ※
※ ※
DJ Effect setting
DJ Mode: OFF/ISOLAT/FLANGE/PAN/WAH
DJ Setting Value: 1~ 40
DJ Mode: OFF/ISOLAT/FLANGE/PAN/WAH
DJ Setting Value: 1~ 40
B
A
Z
U
C
A
※ ※ ※
Bass Bazuca setting (OFF / ON)
Ver. 1.1
Note:
*1
SHAKE33/SHAKE55/SHAKE77 models
*2
SHAKE44/SHAKE66/SHAKE88 models
HCD-SHAKE33/SHAKE44/SHAKE55/SHAKE66/SHAKE77/SHAKE88
19
Ver. 1.1
[MODEL & DEST WRITE MODE]
This mode is used to set software model & destination.
This mode only available when no permanent model & destination
is stored.
This mode is used to set software model & destination.
This mode only available when no permanent model & destination
is stored.
Procedure:
1. Press [MOVIE/GAME] button & [LED PATTERN] button
simultaneously and hold for 5 seconds.
2. Fluorescent indicator tube display will show “M XXXXX”.
3. Press
3. Press
[
+]
*1
/ [PRESET + +]
*2
/ [‒
]
*1
/ [‒ PRESET ‒]
*2
button to select the model based on the set’s model.
Product Code
F. Tube display
SHAKE-33
“M MAGMA3”
SHAKE-55
“M MAGMA5”
SHAKE-77
“M MAGMA7”
SHAKE-44D
“M MAGMA3D”
SHAKE-66D
“M MAGMA5D”
SHAKE-88D
“M MAGMA7D”
4. Press [ENTER] button.
5. Fluorescent indicator tube display will show “D XXXXX”.
6. Press
5. Fluorescent indicator tube display will show “D XXXXX”.
6. Press
[
+]
*1
/ [PRESET + +]
*2
/ [‒
]
*1
/ [‒ PRESET ‒]
*2
button to select the destination based on the set’s country.
Area Code
Country
F. Tube display
J1
Japan
“D J”
JE1
Tourist
“D JE”
U2/CA2
America, Canada
“D NA”
CEL/CE1/
CE2
CE2
Europe(general)
“D CE2”
CEK
U.K.
“D CEK”
RU1/RU3
Russia
“D RU”
AU1
Australia
“D AU”
CN1
China
“D CN”
E12
India, Pakistan, Morocco
“D E12”
E3/E15
Middle East, Iran
“D E3”
E4/EA3/
E93/SA2
E93/SA2
Saudi Arabia, Africa
“D EA3”
HK1/
HK2/PL1/
SP1/SP2/
SP6/TH1
HK2/PL1/
SP1/SP2/
SP6/TH1
Hong Kong, Philippines,
Singapore, Malaysia,
Thailand
Singapore, Malaysia,
Thailand
“D ASIA”
KR2
Korea
“D KR”
TW2
Taiwan
“D TW”
E2, E32,
E51, AR2
E51, AR2
Latin America(general),
Chile, Peru, Argentina
Chile, Peru, Argentina
“D LATIN”
BR1
Brazil
“D BR”
MX2,
MX4
MX4
Mexico
“D MX”
7. Press [ENTER] button to confi rm the selection.
8. “RESET” appears on the fl uorescent indicator tube. After that,
8. “RESET” appears on the fl uorescent indicator tube. After that,
the fl uorescent indicator tube becomes blank for a while, and
the system is reset.
the system is reset.
9. Mode in [PANEL TEST MODE] again to confi rm on the
model & destination.
[DVD COLOR SYSTEM MODE]
•
•
This mode let you change the color system of the video output
from PAL to NTSC or vice-versa.
from PAL to NTSC or vice-versa.
Procedure:
1. Press the [\/1] button to turn on the system.
2. Press the [DVD/CD] button.
3. Press the [DVD/CD] button and [PAN] button simultaneously
1. Press the [\/1] button to turn on the system.
2. Press the [DVD/CD] button.
3. Press the [DVD/CD] button and [PAN] button simultaneously
and hold for 3 seconds.
4. The message “COLOR PAL” or “COLOR NTSC” appears on
the fl uorescent indicator tube.
•
To release from DVD Color System Mode
1. Once the color system has been selected, the mode is fi xed
there after. If you wish to change the mode again, perform the
above item 2 again.
above item 2 again.
[DVD SERVICE MODE]
• This mode let you make diagnosis and adjustment easily by
• This mode let you make diagnosis and adjustment easily by
using the remote commander and the TV. The instructions,
diagnostic results, etc. are given on the on-screen display.
diagnostic results, etc. are given on the on-screen display.
•
TEST DISC LIST
Be sure to use the DVD disc that matches the signal standards
of your region.
of your region.
• CD
YEDS-18
(Part No.: 3-702-101-01)
PATD-012
(Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
PAL :
HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Double Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
PAL :
HLX-507 (Part No.: J-6090-078-A)
•
Procedure to enter to DVD Service Mode:
1. Press the [\/1] button to turn on the system.
2. Press the [DVD/CD] button.
3. Press the [DVD/CD] button and [WAH] button simultaneously
2. Press the [DVD/CD] button.
3. Press the [DVD/CD] button and [WAH] button simultaneously
and hold 3 seconds.
4. The message “SERVICE IN” appears on the fl uorescent
indicator tube.
The display of the “Model Name” of the “Remocon Diagnosis
Menu” change with the model and the destination appears on
screen display. Refer to below on the model name.
Menu” change with the model and the destination appears on
screen display. Refer to below on the model name.
HCD-SHAKE44:
MAGMA3D
HCD-SHAKE66:
MAGMA5D
HCD-SHAKE88:
MAGMA7D
*1: Changes depending on destination
5. To execute each function, press its number by using numeric
button on the remote commander.
6. To release from this mode, press the [\/1] button to turn off
the system.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
Model Name
IF-con
Syscon
IF-con
Syscon
: GSX8D_ XX
*1
: Ver. XX.XX (XXXX)
: Ver. X.XXX
: Ver. X.XXX
Note:
*1
SHAKE33/SHAKE55/SHAKE77 models
*2
SHAKE44/SHAKE66/SHAKE88 models
HCD-SHAKE33/SHAKE44/SHAKE55/SHAKE66/SHAKE77/SHAKE88
20
Ver. 1.1
•
Execute IOP Measurement
In order to execute IOP measurement, the following standard
procedures must be followed.
procedures must be followed.
1. From the Top Menu of Remocon Diagnosis Menu, select
“2. Drive Manual Operation” by pressing the [2] button on
the remote commander. The following screen appears on the
onscreen display.
the remote commander. The following screen appears on the
onscreen display.
2. Select “3. Manual Adjustment” by pressing the [3] button on
the remote commander. The following screen appears on the
on-screen display.
on-screen display.
3. Select “6. Iop:” by pressing the [6] button on the remote
commander.
4. Wait until a hexadecimal number appears in the on-screen
display as below:
5. Convert data from hexadecimal to decimal by using
conversion table.
6. Please
fi nd the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
7. Subtract between these two values.
8. If the remainder is smaller than 93 (decimal), then it is OK.
8. If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defective
and need to be change.
and need to be change.
9. Press the [RETURN] button on the remote commander to
return to previous menu.
10. Press the [0] button on the remote commander to return to the
Top Menu of Remocon Diagnosis Menu.
11. Press the [\/1] button to turn off the system.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o Change Value
RETURN Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o Change Value
RETURN Return to previous menu
•
Check Emergency History
To check the emergency history, please follow the following
procedure.
procedure.
1. From the Top Menu of Remocon Diagnosis Menu, select
“3. Emergency History” by pressing the [3] button on the
remote commander. The following screen appears on the on-
screen display.
remote commander. The following screen appears on the on-
screen display.
2. You can check the total time when the laser is turned on
during playback of DVD and CD from the above menu. The
maximum time, which can be displayed are 999h 59min.
maximum time, which can be displayed are 999h 59min.
3. You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press the [.] button or [>] button
on the remote commander. The error code consists of
emergency history, press the [.] button or [>] button
on the remote commander. The error code consists of
• Error
Code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page
Prev Prev Page
O Return to Top Menu
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Click on the first or last page to see other HCD-SHAKE33 / HCD-SHAKE44 / HCD-SHAKE55 / HCD-SHAKE66 / HCD-SHAKE77 / HCD-SHAKE88 service manuals if exist.