DOWNLOAD Sony HCD-SHAKE33 / HCD-SHAKE44 / HCD-SHAKE55 / HCD-SHAKE66 / HCD-SHAKE77 / HCD-SHAKE88 Service Manual ↓ Size: 12.91 MB | Pages: 126 in PDF or view online for FREE

Model
HCD-SHAKE33 HCD-SHAKE44 HCD-SHAKE55 HCD-SHAKE66 HCD-SHAKE77 HCD-SHAKE88
Pages
126
Size
12.91 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-shake33-hcd-shake44-hcd-shake55-hcd-shake66-hc.pdf
Date

Sony HCD-SHAKE33 / HCD-SHAKE44 / HCD-SHAKE55 / HCD-SHAKE66 / HCD-SHAKE77 / HCD-SHAKE88 Service Manual ▷ View online

HCD-SHAKE33/SHAKE44/SHAKE55/SHAKE66/SHAKE77/SHAKE88
17
SECTION  3
TEST  MODE
[PANEL TEST MODE]
This mode is used to check the fl uorescent indicator tube, LEDs, 
keys, [VOLUME/DJ CONTROL] jog, model, destination and 
software version.
Procedure:
1. Press 
[OPTIONS]
*1
 / [X]
*2
 button and [FOOTBALL] button 
simultaneously and hold 3 seconds.
2.  All LEDs and segments in fl uorescent indicator tube are lighted
up. All RGB LEDs are lighted up in white color.
3.  When you want to enter to the software version display mode, 
press [
+]
*1
 / [PRESET + +]
*2
 button.
 
The model information appears on the fl uorescent  indicator 
tube.
 Press 
[
+]
*1
 / [PRESET + +]
*2
 button again to view the 
destination information.
4.  During the destination information display, press [
+]
*1
 / 
[PRESET + +]
*2
 button. Each time [
+]
*1
 / [PRESET + 
+]
*2
 button is pressed, the fl uorescent indicator tube 
shows the version of each category software in the following 
sequence: SC, MTK, OPU, UI, PF, SYS, CD, CDMA, CDMB, 
ST, TA, TM and return back to model information display.
5. When 
[] button is pressed while the version numbers are 
being displayed except model and destination, the date of the 
software creation appears. When [] button is pressed again, 
the display returns to the software version display.
6. Press 
[‒
]
*1
 / [‒ PRESET ‒]
*2
 button, the key check mode 
is activated.
7.  In the key check mode, the fluorescent indicator tube displays 
“K 0    V0”.
 
Each time a button is pressed, “K” value increases. However, 
once a button has been pressed, it is no longer taken into 
account.
 
“V” value increases in the manner of 0, 1, 2, 3 ... if 
[VOLUME/DJ CONTROL] knob is turned clockwise, or 
it decreases in the manner of 0, 9, 8, 7 ... if [VOLUME/DJ 
CONTROL] knob is turned counterclockwise.
8.  When [ENTER] button is pressed after all LEDs and segments 
in  fl uorescent indicator tube light up, alternate segments in 
fl uorescent indicator tube and LEDs would light up, all RGB 
LEDs would light up in red color. If you press [ENTER] 
button again, another half of alternate segments in fl uorescent 
indicator tube and LEDs would light up, all RGB LEDs 
would light up in green color. Pressing [ENTER] button again 
would cause all segments in fl uorescent indicator tube and 
LEDs light up, all RGB LEDs would light up in blue color. 
Pressing [ENTER] button again would turn off all segments in 
fl uorescent indicator tube and all LEDs including RGB LEDs.
9.  To release from this mode, press the buttons in the same 
manner as step 1, or disconnect the power cord.
[USER RESET]
The user reset clears all data including preset data stored in the data 
fl ash to initial conditions exclude history mode data.
Procedure:
1. Press 
[
\/1
] button to turn on the system.
2. Press 
[] button and [LED COLOR] button simultaneously 
for 3 seconds.
3.  “RESET” appears on the fl uorescent indicator tube. After that, 
the fl uorescent indicator tube becomes blank for a while, and 
the system is reset.
Ver. 1.1
Note: 
*1
 SHAKE33/SHAKE55/SHAKE77 models
*2
 SHAKE44/SHAKE66/SHAKE88 models
[COLD RESET]
The cold reset clears all data including preset data stored in the 
data fl ash to initial conditions included history mode data. Execute 
this mode when returning the set to the customer.
Procedure:
1. Press 
[
\/1
] button to turn on the system.
2. Press 
[] button and [OPTIONS]
*1
 / [X]
*2
 button simultane-
ously for 3 seconds.
3.  “COLD RESET” appears on the fl uorescent indicator tube. 
After that, the fl uorescent indicator tube becomes blank for a 
while, and the system is reset.
[CD TRAY LOCK MODE]
This mode let you lock the disc tray. When this mode is activated, 
the disc tray will not open when [ZOPEN/CLOSE] button is 
pressed. The message “LOCKED” will be displayed on the 
fl uorescent indicator tube. This mode only applied when there is 
disc(s) on the tray.
Procedure:
1. Press 
[
\/1
] button to turn on the system.
2.  Select DVD/CD function.
3. Press [] button and [
+]
*1
 / [PRESET + +]
*2
 
button simultaneously and hold down until “LOCKED” or 
“UNLOCKED” displayed on the fl uorescent indicator tube 
(around 5 seconds).
HCD-SHAKE33/SHAKE44/SHAKE55/SHAKE66/SHAKE77/SHAKE88
18
[HISTORY MODE]
This mode is used to check important data stored in the system 
when PROTECTOR happen.
Procedure:
1.  During demo mode, press [OPTIONS]
*1
 / [X]
*2
 button and 
[FLANGER] button for 5 seconds to mode into history mode.
2.  Press the [TUNING + M > 
]
*1
 / [TUNING + >]
*2
   
button  or [TUNING ‒ 
  . m]
*1
 / [TUNING  ‒  .]
*2
 
button to check history data stored.
To release from History Mode.
To release from this mode, press [
\/1
] button.
Protect Type Description:
Error Code 
Description
E01
The over current condition to MOSFET occurs 
by defect of MOSFET or defect of PS output 
line.
E03
Defect of power supply circuit to AMP.
There is possibility of unusual power supply of 
any of the AMP IC or Pre-amplifi er.
E04
DC appears in SP terminal by defect of AMP 
IC and MOSFET
or
Defect of DC FAN and DC FAN driver circuit
E05
Unusual heat up of MOSFET by improper 
assembly of heat sink, destruction of MOSFET 
etc.
If speaker does not have output even if the set status is not in 
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.
Display on fl uorescent indicator tube
Description
P
R
O
C
O
U
N
T
※ ※
No of time protector happen (0 ~ 99)
P
R
O
T
Y
P
E
※ ※ ※ ※
Refer to protect type description
T
1
※ ※ ※ ※ ※
H
※ ※
M
Single Power On Time until protector happened
(0~99999 hours, 0~99Min)
T
2
※ ※ ※ ※ ※
H
※ ※
M
Total Power On Time [ no consider protector happen ]
(0~99999 hours, 0~99Min)
F
U
N
C
※ ※ ※ ※ ※ ※ ※
Input Function during protector happened
V
O
L
※ ※ ※
Volume setting (MIN / 1 - 50 / MAX)
A
T
T
※ ※ ※
Actual attenuation (-87 … 0)
E
Q
L
O
W
※ ※ ※
Low EQ level (-6 … 0 … +6)
E
Q
M
I
D
※ ※ ※
Mid EQ level (-6 … 0 … +6)
E
Q
H
I
G
H
※ ※ ※
High EQ level (-6 … 0 … +6)
S
U
R
R
※ ※ ※
Surround setting (OFF / ON)
D
J
※ ※ ※ ※ ※ ※
※ ※
DJ Effect setting
DJ Mode: OFF/ISOLAT/FLANGE/PAN/WAH
DJ Setting Value: 1~ 40 
B
A
Z
U
C
A
※ ※ ※
Bass Bazuca setting (OFF / ON)
Ver. 1.1
Note: 
*1
 SHAKE33/SHAKE55/SHAKE77 models
*2
 SHAKE44/SHAKE66/SHAKE88 models
HCD-SHAKE33/SHAKE44/SHAKE55/SHAKE66/SHAKE77/SHAKE88
19
Ver. 1.1
[MODEL & DEST WRITE MODE]
This mode is used to set software model & destination.
This mode only available when no permanent model & destination 
is stored.
Procedure:
1.  Press [MOVIE/GAME] button & [LED PATTERN] button 
simultaneously and hold for 5 seconds.
2.  Fluorescent indicator tube display will show “M XXXXX”.
3. Press 
[
+]
*1
 / [PRESET + +]
*2
 / [‒
]
*1
 / [‒ PRESET ‒]
*2
button to select the model based on the set’s model.
Product Code
F. Tube display
SHAKE-33
“M MAGMA3”
SHAKE-55
“M MAGMA5”
SHAKE-77
“M MAGMA7”
SHAKE-44D
“M MAGMA3D”
SHAKE-66D
“M MAGMA5D”
SHAKE-88D
“M MAGMA7D”
4.  Press [ENTER] button.
5.  Fluorescent indicator tube display will show “D XXXXX”.
6. Press 
[
+]
*1
 / [PRESET + +]
*2
 / [‒
]
*1
 / [‒ PRESET ‒]
*2
button to select the destination based on the set’s country.
Area Code
Country
F. Tube display
J1
Japan
“D J”
JE1
Tourist
“D JE”
U2/CA2
America, Canada
“D NA”
CEL/CE1/
CE2
Europe(general)
“D CE2”
CEK
U.K.
“D CEK”
RU1/RU3
Russia
“D RU”
AU1
Australia
“D AU”
CN1
China
“D CN”
E12
India, Pakistan, Morocco
“D E12”
E3/E15
Middle East, Iran
“D E3”
E4/EA3/
E93/SA2
Saudi Arabia, Africa
“D EA3”
HK1/
HK2/PL1/
SP1/SP2/
SP6/TH1
Hong Kong, Philippines, 
Singapore, Malaysia, 
Thailand
“D ASIA”
KR2
Korea
“D KR”
TW2
Taiwan
“D TW”
E2, E32, 
E51, AR2
Latin America(general), 
Chile, Peru, Argentina
“D LATIN”
BR1
Brazil
“D BR”
MX2, 
MX4
Mexico
“D MX”
7.  Press [ENTER] button to confi rm the selection.
8.  “RESET” appears on the fl uorescent indicator tube. After that, 
the fl uorescent indicator tube becomes blank for a while, and 
the system is reset.
9.  Mode in [PANEL TEST MODE] again to confi rm on the 
model & destination.
[DVD COLOR SYSTEM MODE]
 
This mode let you change the color system of the video output 
from PAL to NTSC or vice-versa.
Procedure:
1.  Press the [\/1] button to turn on the system.
2.  Press the [DVD/CD] button.
3.  Press the [DVD/CD] button and [PAN] button simultaneously 
and hold for 3 seconds.
4.  The message “COLOR PAL” or “COLOR NTSC” appears on 
the fl uorescent indicator tube.
• 
To release from DVD Color System Mode
1.  Once the color system has been selected, the mode is fi xed 
there after. If you wish to change the mode again, perform the 
above item 2 again.
[DVD SERVICE MODE]
  This mode let you make diagnosis and adjustment easily by 
using the remote commander and the TV. The instructions, 
diagnostic results, etc. are given on the on-screen display.
• 
TEST DISC LIST
 
Be sure to use the DVD disc that matches the signal standards 
of your region.
 
•  CD
 
 
 
YEDS-18 
(Part No.: 3-702-101-01)
 
 
 
PATD-012 
(Part No.: 4-225-203-01)
 
•  DVD SL (Single Layer)
 
 
NTSC :  HLX-503  (Part No.: J-6090-069-A)
 
 
 
  HLX-504  (Part No.: J-6090-088-A)
 
 
PAL : 
HLX-506  (Part No.: J-6090-077-A)
 
•  DVD DL (Double Layer)
 
 
NTSC :  HLX-501  (Part No.: J-6090-071-A)
 
 
 
  HLX-505  (Part No.: J-6090-089-A)
 
 
PAL : 
HLX-507  (Part No.: J-6090-078-A)
• 
Procedure to enter to DVD Service Mode:
1.  Press the [\/1] button to turn on the system.
2.  Press the [DVD/CD] button.
3.  Press the [DVD/CD] button and [WAH] button simultaneously 
and hold 3 seconds.
4.  The message “SERVICE IN” appears on the fl uorescent 
indicator tube.
 
The display of the “Model Name” of the “Remocon Diagnosis 
Menu” change with the model and the destination appears on 
screen display. Refer to below on the model name.
 HCD-SHAKE44: 
MAGMA3D
 HCD-SHAKE66: 
MAGMA5D
 HCD-SHAKE88: 
MAGMA7D
 
*1: Changes depending on destination
5.  To execute each function, press its number by using numeric 
button on the remote commander.
6.  To release from this mode, press the [\/1] button to turn off 
the system.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5.  USB Test Mode Setting
Model Name
IF-con
Syscon
: GSX8D_ XX 
*1
: Ver.  XX.XX (XXXX)
: Ver.  X.XXX
Note: 
*1
 SHAKE33/SHAKE55/SHAKE77 models
*2
 SHAKE44/SHAKE66/SHAKE88 models
HCD-SHAKE33/SHAKE44/SHAKE55/SHAKE66/SHAKE77/SHAKE88
20
Ver. 1.1
• 
Execute IOP Measurement
 
In order to execute IOP measurement, the following standard 
procedures must be followed.
1.  From the Top Menu of Remocon Diagnosis Menu, select 
“2. Drive Manual Operation” by pressing the [2] button on 
the remote commander. The following screen appears on the 
onscreen display.
2.  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The following screen appears on the 
on-screen display.
3.  Select “6. Iop:” by pressing the [6] button on the remote 
commander.
4.  Wait until a hexadecimal number appears in the on-screen 
display as below:
5. Convert data from hexadecimal to decimal by using 
conversion table.
6. Please 
fi nd the label on the rear of the BU (Base Unit).
 
The default IOP value is written in the label.
7.  Subtract between these two values.
8.  If the remainder is smaller than 93 (decimal), then it is OK.
 
However if the value is higher than 93, then the BU is defective 
and need to be change.
9.  Press the [RETURN] button on the remote commander to 
return to previous menu.
10.  Press the [0] button on the remote commander to return to the 
Top Menu of Remocon Diagnosis Menu.
11.  Press the [\/1] button to turn off the system.
 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
 
o Change Value
RETURN  Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
 
o Change Value
RETURN  Return to previous menu
• 
Check Emergency History
 
To check the emergency history, please follow the following 
procedure.
1.  From the Top Menu of Remocon Diagnosis Menu, select 
“3. Emergency History” by pressing the [3] button on the 
remote commander. The following screen appears on the on-
screen display.
2.  You can check the total time when the laser is turned on 
during playback of DVD and CD from the above menu. The 
maximum time, which can be displayed are 999h 59min.
3.  You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press the [.] button or [>] button 
on the remote commander. The error code consists of
• Error 
Code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
Emg. History Check
1.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
Next   Next Page
Prev   Prev Page
O  Return to Top Menu
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
Page of 126
Display

Click on the first or last page to see other HCD-SHAKE33 / HCD-SHAKE44 / HCD-SHAKE55 / HCD-SHAKE66 / HCD-SHAKE77 / HCD-SHAKE88 service manuals if exist.