13
0
chassis, assy (M9)
1
six screws
(+PWH 3
u 8 (SUMITITE))
4
chassis, sub (M9)
2
holder, wire
3
holder, wire
5
CN101/
CN102
(3P)
7
ten screws
(+PWH 3
u 8 (SUMITITE))
9
SWITCHING REGULATOR
8
clamp
6
(SHAKE99: US, AUS/
HCDSHAKE100: EA,
MY, SAF)
HCDSHAKE100: EA,
MY, SAF)
2-8. SWITCHING
REGULATOR
Ver. 1.2
• Abbreviation
AUS :
AUS :
Australian
model
EA
: Saudi Arabia model
MY
: Malaysia model
SAF
: South African model
HCD-SHAKE99/HCDSHAKE100
14
8
four insulator screws
7
connector
qa
insulator
6
belt
3
Insert the thin
wire (clip etc.).
5
tray
qs
service,
optical
device(7G)
qa
insulator
qa
insulator
qh
qk
cable, flexible flat
(24
core)
qg
tape
1
six claws
4
9
0
2
chuck holder assy (T)
2
Solder the short-land.
qf
wire (flat type)
(5
core)
– Bottom view –
loading assy (T)
qd
base, lo assy
qj
holder, FFC
Note 2: When assembling the optical
pick-up block, remove the solder of
short-land after connecting the
cable, flexible flat (24 core).
2-9. SERVICE, OPTICAL DEVICE(7G), CABLE, FLEXIBLE FLAT
Note 1 : Before disconnecting the cable, fl exible fl at (24 core) of optical pick-up block, solder the short-land.
Under the guide
Under the guide
(Fold area)
(Fold area)
,QVWDOODWLRQRIFDEOHIOH[LEOHIODWFRUHDQGZLUHIODWW\SHFRUH
Note: This illustration sees the loading assy (T) from bottom side.
1
cable, flexible flat (24 core)
2
Through the hole
3
Through the hole
4
terminal face
loading assy (T)
7
cable, flexible flat
(24
core)
6
holder, FFC
5
three claws
5
two claws
8
wire (flat type)
(5
core)
9
tape
Ver. 1.1
HCD-SHAKE99/HCDSHAKE100
15
SECTION 3
TEST MODE
[PANEL TEST MODE]
This mode is used to check the fl uorescent indicator tube, LEDs,
keys, [VOLUME/DJ CONTROL] jog, model, destination and
software version.
This mode is used to check the fl uorescent indicator tube, LEDs,
keys, [VOLUME/DJ CONTROL] jog, model, destination and
software version.
Procedure:
1. Press
[OPTIONS]
*1
/ [X]
*2
button and [FOOTBALL] button
simultaneously and hold 3 seconds.
2. All LEDs and segments in fl uorescent indicator tube are
lighted up. All RGB LEDs are lighted up in white color.
3. When you want to enter to the software version display mode,
press [
+]
*1
/ [PRESET + +]
*2
button.
The model information appears on the fl uorescent indicator
tube.
tube.
Press
[
+]
*1
/ [PRESET + +]
*2
button again to view the
destination information.
4.
During the destination information display, press
[
[
+]
*1
/ [PRESET + +]
*2
button. Each time [
+]
*1
/
[PRESET + +]
*2
button is pressed, the fl uorescent indicator
tube shows the version of each category software in the following
sequence: SC, MTK, OPU, UI, PF, SYS, CD, CDMA, CDMB,
ST, TA, TM and return back to model information display.
sequence: SC, MTK, OPU, UI, PF, SYS, CD, CDMA, CDMB,
ST, TA, TM and return back to model information display.
5. When [] button is pressed while the version numbers
are being displayed except model and destination, the
date of the software creation appears. When [] button is
pressed again, the display returns to the software version
display.
date of the software creation appears. When [] button is
pressed again, the display returns to the software version
display.
6. Press
[‒
]
*1
/ [‒ PRESET ‒]
*2
button, the key check mode
is activated.
7. In the key check mode, the fl uorescent indicator tube displays
“K 0 V0”.
Each time a button is pressed, “K” value increases. However,
once a button has been pressed, it is no longer taken into
account.
once a button has been pressed, it is no longer taken into
account.
“V” value increases in the manner of 0, 1, 2, 3 ... if [VOLUME/
DJ CONTROL] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8, 7 ... if [VOLUME/DJ CONTROL] knob is
turned counterclockwise.
DJ CONTROL] knob is turned clockwise, or it decreases in the
manner of 0, 9, 8, 7 ... if [VOLUME/DJ CONTROL] knob is
turned counterclockwise.
8. When [ENTER] button is pressed after all LEDs and segments
in fl uorescent indicator tube light up, alternate segments in
fl uorescent indicator tube and LEDs would light up, all RGB
LEDs would light up in red color. If you press [ENTER]
button again, another half of alternate segments in fl uorescent
indicator tube and LEDs would light up, all RGB LEDs
would light up in green color. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up, all RGB LEDs would light up in blue color.
Pressing [ENTER] button again would turn off all segments in
fl uorescent indicator tube and all LEDs including RGB LEDs.
fl uorescent indicator tube and LEDs would light up, all RGB
LEDs would light up in red color. If you press [ENTER]
button again, another half of alternate segments in fl uorescent
indicator tube and LEDs would light up, all RGB LEDs
would light up in green color. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up, all RGB LEDs would light up in blue color.
Pressing [ENTER] button again would turn off all segments in
fl uorescent indicator tube and all LEDs including RGB LEDs.
9. To release from this mode, press the buttons in the same
manner as step 1, or disconnect the power cord.
Ver. 1.1
Note:
*1
SHAKE99 model
*2
HCDSHAKE100 model
[USER RESET]
The user reset clears all data including preset data stored in the data
fl ash to initial conditions exclude history mode data.
The user reset clears all data including preset data stored in the data
fl ash to initial conditions exclude history mode data.
Procedure:
1. Press
\/1
button to turn on the system.
2. Press
[] button and [LED COLOR] button simultaneously
for 3 seconds.
3. “RESET” appears on the fl uorescent indicator tube. After that,
the fl uorescent indicator tube becomes blank for a while, and
the system is reset.
the system is reset.
[COLD RESET]
The cold reset clears all data including preset data stored in the
data fl ash to initial conditions included history mode data. Execute
this mode when returning the set to the customer.
The cold reset clears all data including preset data stored in the
data fl ash to initial conditions included history mode data. Execute
this mode when returning the set to the customer.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Press
[] button and [OPTIONS]
*1
/ [X]
*2
button simultane-
ously for 3 seconds.
3. “COLD RESET” appears on the fl uorescent indicator tube.
After that, the fl uorescent indicator tube becomes blank for a
while, and the system is reset.
while, and the system is reset.
[CD TRAY LOCK MODE]
This mode let you lock the disc tray. When this mode is activated,
the disc tray will not open when [ZOPEN/CLOSE] button is
pressed. The message “LOCKED” will be displayed on the
fl uorescent indicator tube. This mode only applied when there is
disc(s) on the tray.
This mode let you lock the disc tray. When this mode is activated,
the disc tray will not open when [ZOPEN/CLOSE] button is
pressed. The message “LOCKED” will be displayed on the
fl uorescent indicator tube. This mode only applied when there is
disc(s) on the tray.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Select DVD/CD function.
3. Press [] button and [
3. Press [] button and [
+]
*1
/ [PRESET + +]
*2
button simultaneously and hold down until “LOCKED” or
“UNLOCKED” displayed on the fl uorescent indicator tube
(around 5 seconds).
“UNLOCKED” displayed on the fl uorescent indicator tube
(around 5 seconds).
HCD-SHAKE99/HCDSHAKE100
16
Display on fl uorescent indicator tube
Description
P
R
O
C
O
U
N
T
※ ※
No of time protector happen (0 ~ 99)
P
R
O
T
Y
P
E
※ ※ ※ ※
Refer to protect type description
T
1
※ ※ ※ ※ ※
H
※ ※
M
Single Power On Time until protector happened
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
T
2
※ ※ ※ ※ ※
H
※ ※
M
Total Power On Time [ no consider protector happen ]
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
F
U
N
C
※ ※ ※ ※ ※ ※ ※
Input Function during protector happened
V
O
L
※ ※ ※
Volume setting (MIN / 1 - 50 / MAX)
A
T
T
※ ※ ※
Actual attenuation (-87 … 0)
E
Q
L
O
W
※ ※ ※
Low EQ level (-6 … 0 … +6)
E
Q
M
I
D
※ ※ ※
Mid EQ level (-6 … 0 … +6)
E
Q
H
I
G
H
※ ※ ※
High EQ level (-6 … 0 … +6)
S
U
R
R
※ ※ ※
Surround setting (OFF / ON)
D
J
※ ※ ※ ※ ※ ※
※ ※
DJ Effect setting
DJ Mode: OFF/ISOLAT/FLANGE/PAN/WAH
DJ Setting Value: 1~ 40
DJ Mode: OFF/ISOLAT/FLANGE/PAN/WAH
DJ Setting Value: 1~ 40
B
A
Z
U
C
A
※ ※ ※
Bass Bazuca setting (OFF / ON)
[HISTORY MODE]
This mode is used to check important data stored in the system
when PROTECTOR happen.
This mode is used to check important data stored in the system
when PROTECTOR happen.
Procedure:
1. During demo mode, press [OPTIONS]
*1
/ [X]
*2
button and
[FLANGER] button for 5 seconds to mode into history mode.
2. Press the [M >
TUNING +]
*1
/ [TUNING + >]
*2
button or [
. m TUNING ‒]
*1
/ [. TUNING ‒]
*2
button to check history data stored.
To release from History Mode.
To release from this mode, press [
To release from this mode, press [
\/1
] button.
Ver. 1.1
Note:
*1
SHAKE99 model
*2
HCDSHAKE100 model
Protect Type Description:
Error Code
Description
E01
The over current condition to MOSFET occurs
by defect of MOSFET or defect of PS output
line.
by defect of MOSFET or defect of PS output
line.
E03
Defect of power supply circuit to AMP.
There is possibility of unusual power supply of
any of the AMP IC or Pre-amplifi er.
There is possibility of unusual power supply of
any of the AMP IC or Pre-amplifi er.
E04
DC appears in SP terminal by defect of AMP
IC and MOSFET
or
Defect of DC FAN and DC FAN driver circuit
IC and MOSFET
or
Defect of DC FAN and DC FAN driver circuit
E05
Unusual heat up of MOSFET by improper
assembly of heat sink, destruction of MOSFET
etc.
assembly of heat sink, destruction of MOSFET
etc.
If speaker does not have output even if the set status is not in
PROTECT mode, the following defect might be possible:
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.