Sony HCD-SHAKE100 / HCD-SHAKE99 Service Manual ▷ View online
HCD-SHAKE99/HCDSHAKE100
17
Ver. 1.1
[MODEL & DEST WRITE MODE]
This mode is used to set software model & destination.
This mode only available when no permanent model & destination
is stored.
This mode is used to set software model & destination.
This mode only available when no permanent model & destination
is stored.
Procedure:
1. Press [MOVIE/GAME] button & [LED PATTERN] button
simultaneously and hold for 5 seconds.
2. Fluorescent indicator tube display will show “M XXXXX”.
3. Press
3. Press
[
+]
*1
/ [PRESET + +]
*2
/ [‒
]
*1
/ [‒ PRESET ‒]
*2
button to select the model based on the set’s model.
Product Code
F. Tube display
SHAKE-99/SHAKE-100D
“M MAGMA9/MAGMA9D”
4. Press [ENTER] button.
5. Fluorescent indicator tube display will show “D XXXXX”.
6. Press [
5. Fluorescent indicator tube display will show “D XXXXX”.
6. Press [
+]
*1
/ [PRESET + +]
*2
/ [‒
]
*1
/ [‒ PRESET ‒]
*2
button to select the destination based on the set’s country.
Area Code
Country
F. Tube display
J1
Japan
“D J”
JE1
Tourist
“D JE”
U2/CA2
America, Canada
“D NA”
CEL/CE1/
CE2
CE2
Europe(general)
“D CE2”
CEK
U.K.
“D CEK”
RU1/RU3
Russia
“D RU”
AU1
Australia
“D AU”
CN1
China
“D CN”
E12
India, Pakistan, Morocco
“D E12”
E3/E15
Middle East, Africa
(South Africa), Iran
(South Africa), Iran
“D E3”
E4/EA3/
E93/SA2
E93/SA2
Saudi Arabia, Africa
“D EA3”
HK1/
HK2/PL1/
SP1/SP2/
SP6/TH1
HK2/PL1/
SP1/SP2/
SP6/TH1
Hong Kong, Philippines,
Singapore, Malaysia,
Thailand
Singapore, Malaysia,
Thailand
“D ASIA”
KR2
Korea
“D KR”
TW2
Taiwan
“D TW”
E2, E32,
E51, AR2
E51, AR2
Latin America(general),
Chile, Peru, Argentina
Chile, Peru, Argentina
“D LATIN”
BR1
Brazil
“D BR”
MX2,
MX4
MX4
Mexico
“D MX”
7. Press [ENTER] button to confi rm the selection.
8. “RESET” appears on the fl uorescent indicator tube. After that,
8. “RESET” appears on the fl uorescent indicator tube. After that,
the fl uorescent indicator tube becomes blank for a while, and
the system is reset.
the system is reset.
9. Mode in [PANEL TEST MODE] again to confi rm on the
model & destination.
Note:
*1
SHAKE99 model
*2
HCDSHAKE100 model
[DVD COLOR SYSTEM MODE]
•
•
This mode let you change the color system of the video output
from PAL to NTSC or vice-versa.
from PAL to NTSC or vice-versa.
Procedure:
1. Press the [\/1] button to turn on the system.
2. Press the [DVD/CD] button.
3. Press the [DVD/CD] button and [PAN] button simultaneously
2. Press the [DVD/CD] button.
3. Press the [DVD/CD] button and [PAN] button simultaneously
and hold for 3 seconds.
4. The message “COLOR PAL” or “COLOR NTSC” appears on
the fl uorescent indicator tube.
•
To release from DVD Color System Mode
1. Once the color system has been selected, the mode is fi xed
there after. If you wish to change the mode again, perform the
above item 2 again.
above item 2 again.
[DVD SERVICE MODE]
• This mode let you make diagnosis and adjustment easily by
• This mode let you make diagnosis and adjustment easily by
using the remote commander and the TV. The instructions,
diagnostic results, etc. are given on the on-screen display.
diagnostic results, etc. are given on the on-screen display.
•
TEST DISC LIST
Be sure to use the DVD disc that matches the signal standards
of your region.
of your region.
• CD
YEDS-18
(Part No.: 3-702-101-01)
PATD-012
(Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
PAL :
HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Double Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
PAL :
HLX-507 (Part No.: J-6090-078-A)
•
Procedure to enter to DVD Service Mode:
1. Press the [\/1] button to turn on the system.
2. Press the [DVD/CD] button.
3. Press the [DVD/CD] button and [WAH] button simultaneously
2. Press the [DVD/CD] button.
3. Press the [DVD/CD] button and [WAH] button simultaneously
and hold 3 seconds.
4. The message “SERVICE IN” appears on the fl uorescent
indicator tube.
The display of the “Model Name” of the “Remocon Diagnosis
Menu” change with the model and the destination appears on
screen display. Refer to below on the model name.
Menu” change with the model and the destination appears on
screen display. Refer to below on the model name.
SHAKE-100D:
MAGMA9D
*1: Changes depending on destination
5. To execute each function, press its number by using numeric
button on the remote commander.
6. To release from this mode, press the [\/1] button to turn off
the system.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
Model Name
IF-con
Syscon
IF-con
Syscon
: GSX8D_ XX
*1
: Ver. XX.XX (XXXX)
: Ver. X.XXX
: Ver. X.XXX
HCD-SHAKE99/HCDSHAKE100
18
•
Check Emergency History
To check the emergency history, please follow the following
procedure.
procedure.
1. From the Top Menu of Remocon Diagnosis Menu, select
“3. Emergency History” by pressing the [3] button on the
remote commander. The following screen appears on the on-
screen display.
remote commander. The following screen appears on the on-
screen display.
2. You can check the total time when the laser is turned on
during playback of DVD and CD from the above menu. The
maximum time, which can be displayed are 999h 59min.
maximum time, which can be displayed are 999h 59min.
3. You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press the [.] button or [>] button
on the remote commander. The error code consists of
emergency history, press the [.] button or [>] button
on the remote commander. The error code consists of
•
Error Code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page
Prev Prev Page
O Return to Top Menu
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
•
Execute IOP Measurement
In order to execute IOP measurement, the following standard
procedures must be followed.
procedures must be followed.
1. From the Top Menu of Remocon Diagnosis Menu, select
“2. Drive Manual Operation” by pressing the [2] button on
the remote commander. The following screen appears on the
onscreen display.
the remote commander. The following screen appears on the
onscreen display.
2. Select “3. Manual Adjustment” by pressing the [3] button on
the remote commander. The following screen appears on the
on-screen display.
on-screen display.
3. Select “6. Iop:” by pressing the [6] button on the remote
commander.
4. Wait until a hexadecimal number appears in the on-screen
display as below:
5. Convert data from hexadecimal to decimal by using
conversion table.
6. Please
fi nd the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
7. Subtract between these two values.
8. If the remainder is smaller than 93 (decimal), then it is OK.
8. If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defective
and need to be change.
and need to be change.
9. Press the [RETURN] button on the remote commander to
return to previous menu.
10. Press the [0] button on the remote commander to return to the
Top Menu of Remocon Diagnosis Menu.
11. Press the [\/1] button to turn off the system.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o Change Value
RETURN Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. ED
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o Change Value
RETURN Return to previous menu
Ver. 1.1
HCD-SHAKE99/HCDSHAKE100
19
•
Parameter of error code
This is the detail of error code.
•
Time of error code
This is the laser time when an error occurred.
To clear the Laser Hours
Press the [
DISPLAY] button and then press the [CLEAR]
button. The data for both CD and DVD data are reset.
To clear the Emergency History
Press the [DVD TOP MENU] button and then press the [CLEAR]
button.
The error code for all emergency history would be reset.
button.
The error code for all emergency history would be reset.
To clear the Initialize Setup Data
Press the [DVD/TUNER MENU] button and then press the
[CLEAR] button on the remote commander.
[CLEAR] button on the remote commander.
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
0h
0min
DVD
0h
0min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page
Prev Prev Page
O Return to Top Menu
Emg. History Check
1. 00 00 00 00
Laser Hours
CD
999h
59min
DVD
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
Next Next Page
Prev Prev Page
O Return to Top Menu
Emg. History Check
Initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
Next Next Page
Prev Prev Page
O Return to Top Menu
Ver. 1.1
To return to the Top Menu of Remocon Diagnosis Menu
Press the [0] button on the remote commander.
•
Check Version Information
To check the version information, please follow the following
procedure.
procedure.
1. From the Top Menu of Remocon Diagnosis Menu, select “4.
Version information” by pressing the [4] button on the remote
commander. The following screen appears on the on-screen
display.
commander. The following screen appears on the on-screen
display.
To return to the Top Menu of Remocon Diagnosis Menu, press
the [0] button on the remote commander.
the [0] button on the remote commander.
Version information
O Return to Top Menu
Firm (Main) : Ver. xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
HCD-SHAKE99/HCDSHAKE100
20
FOCUS BIAS CHECK
Procedure:
1. Connect the oscilloscope to CN302 pin 17 (RFMON) and
1. Connect the oscilloscope to CN302 pin 17 (RFMON) and
CN302 pin 1 (GND) on the MOTHERBOARD board.
2. Press
the
[
?/1
] button to turn the power on, and press the [CD]
(SHAKE99)/[DVD/CD](HCDSHAKE100) button to select
CD/DVD function.
CD/DVD function.
3. Set the test disc (CD: YEDS-18), (DVD: HLX-503 (NTSC)
or HLX-504 (PAL) on the tray and press [u] button to
playback.
playback.
4. Confi rm that oscilloscope waveform is as shown in the fi gure
below (eye pattern).
A good eye pattern means that the diamond shape (
) in the
center of the waveform can be clearly distinguished.
Checking Location:
-MOTHERBOARD Board (CONDUCTOR SIDE)-
-MOTHERBOARD Board (CONDUCTOR SIDE)-
SECTION 4
ELECTRICAL CHECK
Procedure:
1. Turn the power on.
2. Input the following signal from Signal Generator to FM
2. Input the following signal from Signal Generator to FM
antenna input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation
Deviation
: 75 kHz
Modulation
: 1 kHz
ANT input
: 35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the
set. You cannot use video cable for checking.
Please use SG whose output impedance is 75 ohm.
3. Set to FM tuner function and scan the input FM signal with
automatic
automatic
scanning.
4. Confi rm that input Frequency of A, B and C detected and
automatic scanning stops.
The stop of automatic scanning means “The station signal is
received in good condition”.
received in good condition”.
FM AUTO STOP CHECK
signal
generator
set
+
–
75
TUNER SECTION
0 dB = 1
ȝV
CD/DVD SECTION
[TEST DISC LIST]
Use the following test disc on test mode.
• CD:
Use the following test disc on test mode.
• CD:
YEDS-18 (PART No. 3-702-101-01)
or
PATD-012 (PART No. 4-225-203-01)
• DVD (SL)
NTSC
NTSC
HLX-503 (PART No. J-6090-069-A)
or
HLX-504 (PART No. J-6090-088-A)
PAL
HLX-506 (PART No. J-6090-077-A)
• DVD (DL)
NTSC
NTSC
HLX-501 (PART No. J-6090-071-A)
or
HLX-505 (PART No. J-6090-089-A)
PAL
HLX-507 (PART No. J-6090-078-A)
Note: When the BASE UNIT is replaced, perform the Execute
IOP measurement
(Refer to page 18).
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
level:
1.1 ± 0.25 Vp-p (DVDSL)
1.0 ± 0.25 Vp-p (CD)
1.1 ± 0.25 Vp-p (DVDSL)
1.0 ± 0.25 Vp-p (CD)
CN302
pin 1 (GND)
pin 17 (RFMON)
+
–
MOTHERBOARD board
oscilloscope
(DC range)
CN302 pin 17 (RFMON)
CN302 pin 1 (GND)
Ver. 1.1