17
HCD-DX50/RG80
FM Tuned Level Adjustment
Procedure:
1.
Supply a 98 MHz signal at 28 dB from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Adjust RV11 to the point (moment) when the TUNED indicator
will change from going off to going on.
Adjustment Location: MAIN board
Null Adjustment
Procedure:
1.
Supply a 98 MHz signal at 60 dB from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Measure voltage between pin 22 and pin 3 of IC11.  Adjust
T11 until the voltage becomes 0 V.
Adjustment Location: MAIN board
Adjustment Location
[MAIN BOARD] 
 (Component Side)
FM RF SIGNAL GENERATOR
75 
 coaxial
Carrier frequency : 98 MHz
Modulation           : AUDIO 1 kHz, 75 kHz
                              deviation (100%)
Output level          : 28 dB  (at 75 
 open)
FM ANTENNA terminal 
(TM1)
set
FM RF SIGNAL GENERATOR
75 
 coaxial
Carrier frequency : 98 MHz
Modulation           : AUDIO 1 kHz, 75 kHz
                              deviation (100%)
Output level          : 60 dB  (at 75 
 open)
FM ANTENNA terminal 
(TM1)
set
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use LUV-P01 (4-999-032-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1. Connect an oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead
wire.
3. Turn Power switch on.
4. Load a disc (LUV-P01) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
5. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 2 
± 0.5 Vp-p.
6. After check, remove the lead wire connected in step 2.
Note :
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP
(RFAC).
2. Turn Power switch on.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check if RF
signal level is correct or not.
BD board
Oscilloscope
TP(FEO)
TP(DVC)
T11
RV11
RV351
RV354
RV304
RV303
RV302
RV301
CN301
CN304
CN302
CN303
1
3
NULL
FM TUNED LEVEL
TUNER SECTION
symmetry
S-curve waveform
within 2 
±
0.5Vp-p
A
B
TP(RFDC)
TP(RFAC)
BD board
oscilloscope
TP(DVC)
18
HCD-DX50/RG80
Note :
Clear RF signal waveform means that the shape “ 
◊ ” can be clearly
distinguished at the center of the waveform.
E-F Balance (1 Track jump) Check
Procedure :
1. Connect an oscilloscope to TP (TEO) and TP (DVC).
2. Turn Power switch on.
3. Load a disc (LUV-P01) and playback the number nine track.
4. Press the  gG  button. (Becomes the 1 track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
6. Adjust RV101 on the BD board so that the center of waveform
becomes the same voltage of DVC. (i.e.  A=0V)
Adjustment Location:
[BD BOARD] (Conductor Side)
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 0.65 
±
0.15Vp-p (RFDC)
1.1 
±
0.4Vp-p (RFAC)
TP(TEO)
TP(DVC)
BD board
oscilloscope
level=1.0 
±
0.5Vp-p
symmetry
A (DC voltage)
center of
waveform
B
DVC
1 track jump waveform
TP (TEO)
TP
(RFAC)
TP
(FEI)
TP
(RFDC)
TP (FEO)
IC101
IC103
RV101
TP (DVC)
1
15
30
1
20
21
40
60
80
41
61
16
19
HCD-DX50/RG80
SECTION 6
DIAGRAMS
Note on Schematic Diagram:
• All capacitors are in 
µ
F unless otherwise noted.  pF: 
µµ
F
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
¢
: internal component.
C
: panel designation.
Note on Printed Wiring Boards:
• X
: parts extracted from the component side.
: Pattern from the side which enables seeing.
• Indication of transistor.
• 
A
 : B+ Line.
• 
B
 : B– Line.
H
: adjustment for repair.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: FM
f
: AM
E
: PB (DECK A)
d
: PB (DECK B)
G
: REC (DECK B)
J
: CD
c
: digital out
• Abbreviation
AR
: Argentina model
AUS
: Australian model
E51 : Chilean and Peruvian model
KR
: Korea model
MX
: Mexican model
SP
: Singapore model
THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this, the necessary note is printed in each block.)
C
B
These are omitted.
E
Q
B
These are omitted.
C
E
Q
Note:
The components identi-
fied by mark 
0
 or dotted
line with mark 
0
 are criti-
cal for safety.
Replace only with part
number specified.
Note:
Les composants identifiés par
une marque 
0
 sont critiques
pour la sécurité.
Ne les remplacer que par une
piéce por tant le numéro
spécifié.
20
HCD-DX50/RG80
6-1. CIRCUIT BOARD LOCATION
MOTOR board
ADDRESS SENSOR board
DRIVER board
MAIN TRANS board
SWITCH board
SENSOR board
BD board
SUB TRANS board
MAIN board
POWER board
LEAF SW board
HEAD (A) board
HEAD (B) board
PANEL board
CD SWITCH board
PAD SWITCH board
• WAVEFORMS
4
 
IC101 
wh
 (MDP)
2
 
IC101 
ra
       (TE)(CD Play mode)
1
 
IC101 
ta
       (RFAC)(CD Play mode)
3
 
IC101 
el
       (FE)(CD Play mode)
2.5 Vp-p
7.5 
µ
s
0.3 Vp-p
0.4 Vp-p
1.1 Vp-p
– BD BOARD –
– PANEL BOARD –
1
 IC601 
is
 
       STOP MODE
3.0Vp-p
4MHz
1
 IC501 
qa
 
       STOP MODE
3.1Vp-p
32.768kHz
3.8Vp-p
2
 IC501 
qd
 
       STOP MODE
4
 T301 
4
 
       TAPE B REC MODE
16MHz
120Vp-p
4.6Vp-p
3
 IC51 
ws
 
       TUNER (FM)
4.5MHz
80.8kHz
– MAIN BOARD –
Page of 68