DOWNLOAD Sony HCD-RG80 Service Manual ↓ Size: 14.41 MB | Pages: 68 in PDF or view online for FREE

Model
HCD-RG80
Pages
68
Size
14.41 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-rg80.pdf
Date

Sony HCD-RG80 Service Manual ▷ View online

13
HCD-DX50/RG80
* Tape function
1. When a tape is inserted in Deck B and recording is started, the
input source function selects VIDEO automatically.
When  CD SYNC/HI-DUB  button is pressed during Rec in
function, ALC is turned on.
2.   When   x  button is pressed to stop recording, the Tape (Deck)
B is selected and tape is rewound, tape is rewound using  m
button, tape is stops at around the record-starting position and
playback of the recorded portion of the tape is started.  If PAUSE
is inserted even once during recording, tape is rewound to the
position around the PAUSE position and is played back.
3.
When  CD SYNC / HI-DUB  button is pressed during playback
of Deck B, either normal speed or high speed can be selected
by this button.
* AMS Test Mode
1.
Set TAPE function
2.
Select the desired loop by pressing the  PLAY MODE  button.
Insert a test tape AMS-110A or AMS-120 to Deck A.
3.
Press the  SPECTRUM  button to enter the AMS test mode.
4.
After a tape is rewound first, the FF AMS is checked, and the
mechanism is shut off after detecting the AMS signal twice.
5.
Then the REW AMS is checked and the mechanism is shut off
after detecting the AMS signal twice.
6.
When the check is complete, a message of either OK or NG
appears.
* To return to normal mode again.
1.
When you want to exit this mode, press the  ?/1  button.
2.     The cold reset is enforced at the same time.
[VACS ON/OFF Mode]
• This mode is used to switch ON and OFF the VACS (Variable
Attenuation Control System).
Procedure:
Press the  ENTER  and  SPECTRUM  buttons simultaneously.  The
message “VACS OFF” or “VACS ON” appears.
[CD Service Mode]
• This mode can run the CD sled motor freely. Use this mode, for
instance, when cleaning the pickup.
Procedure:
1. Press ?/1 button to turn the set ON.
2. Select the function “CD”.
3. Press three buttons x ,  ENTER , and  OPEN/CLOSE  simul-
taneously.
4. The CD service mode is selected.
5. With the CD in stop status, press 
M
 button  to move the pickup
to outside track, or press 
m
 button to inside track.
6. To exit from this mode, perform as follows:
1) Move the pickup to the most inside track.
2) Press  ?/1  button to turn the set OFF.
Note:
 • Always move the pickup to most inside track when exiting from
this mode.  Otherwise, a disc will not be unloaded.
• Do not run the sled motor excessively, otherwise the gear can be
chipped.
[CD Ship Mode (Memory Clear) ]
• This mode moves the pickup to the position durable to vibra-
tion. Use this mode when returning the set to the customer after
repair.
Procedure:
1. Press
1/u button to turn the set ON.
2. Press  three  buttons  x  , ENTER and GAME  simultaneously.
3. After the "STANDBY" display blinks six times, a message
“LOCK” is displayed on the fluorescent indicator tube, and the
CD ship mode is set.
[CD Ship Mode (No Memory Clear) ]
• This mode moves the pickup to the position durable to vibra-
tion. Use this mode when returning the set to the customer after
repair.
Procedure:
1. Press
1/u button to turn the set ON.
2. Press  CD  button and  
1/u   button simultaneously.
3. After the "STANDBY" display blinks six times, a message
“LOCK” is displayed on the fluorescent indicator tube, and the
CD ship mode is set.
+
14
HCD-DX50/RG80
SECTION 4
MECHANICAL ADJUSTMENTS
SECTION 5
ELECTRICAL ADJUSTMENTS
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Record/Playback Head Azimuth Adjustment
Tape
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300J
315 Hz, 0 dB
Level Adjustment
DECK A      DECK B
Note:
  Perform this adjustments for both decks
Procedure:
1. Mode:  Playback
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
set
main board
CN301
Pin 
3
 (L-CH)
Pin 
1
 (R-CH)
main board
CN301
Pin 
2
 (GND)
+
level meter
test tape
P-4-A100
(10 kHz, –10 dB)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
6.96 N • m to 14.02 N • m
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
9.80 N • m
100 g or more
(3.53 oz or more)
9.80 N • m
100 g or more
(3.53 oz or more)
Mode
Torque meter
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Meter reading
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
15
HCD-DX50/RG80
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
Tape Speed Adjustment
DECK B
Note:
Start the Tape Speed adjustment as below after setting to the test
mode.
In the test mode, the tape speed is high during pressing the
 CD SYNC/HI-DUB 
 button.
Procedure:
1. Turn the power switch on.
2. Press the x button,  ENTER  button and  DISC 3  button
simultaneously.
(The “TEST MODE” on the fluorescent indicator tube display
while in the test mode.)
To exit from the test mode, press the ?/1 button.
Mode:  Playback
1. Insert the WS-48B into the deck B.
2. Press the gG button on the deck B.
3. Press the  CD SYNC/HI-DUB  button in playback mode.
Then at HIGH speed mode.
4. Adjust RV1001 on the LEAF SW board so that frequency
counter reads 6,000 
± 30 Hz.
5. Press the  CD SYNC/HI-DUB  button.
Then back to NORMAL speed mode.
6. Adjust RV1002 on the LEAF SW board so that frequency
counter reads 3,000 
± 15 Hz.
Adjustment Location:  LEAF SW board
Playback level Adjustment
DECK A      DECK B
Procedure:
Mode:  Playback
1. Confirm that level difference between the channels is with 
±
0.5 dB.
2. After check, adjust the following RVs.
Deck A is RV302 (L-CH), Deck B is RV303 (L-CH) so that
adjustment within adjustment level as follows.
Adjustment Level:
CN301 PB level:  334.4 to 748.7 mV (–7.3 to  –0.3 dB)
Adjustment Location:  MAIN board
Sample Volue of Wow and Flutter: 0.3% or less W. RMS
(WS-48B)
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
MAIN
board
CN301
set
test tape
P-4-A100
(10 kHz, –10 dB)
pin 
1
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
2
pin 
3
L
R
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
main board
CN301 (Pin 
3
 : L-CH)
(Pin 
1
 : R-CH)
frequency counter
+
set
test tape
P-4-L300J
(315 Hz, 0 dB)
main board
CN301 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
forward
reverse
16
HCD-DX50/RG80
4. Mode:  Record
5. Mode:  Playback
6. Confirm the play back signal recorded in step 3 becomes
adjustable level as follows.
If these levels are not adjustable level, adjust the RV301 (L-
CH) and RV351 (R-CH) on the MAIN board to repeat steps 4
and 5.
Adjustable level:
CN301 PB level:  47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location:  MAIN board
[MAIN  BOARD] (Component Side)
[LEAF  SW  BOARD]  (Component Side)
REC Bias Adjustment
   DECK B
Procedure:
In the MC test mode, the “REC memory mode” is convenient for
this adjustment. In the “REC memory mode” , when the REC starts
the input signal FUNCTION is switched to VIDEO automatically.
When the REC stops, the tape returns near to the recording start
position.
1. Press  MD (VIDEO)  button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B.
3. After press  REC PAUSE/START  button, press REC PAUSE/
START button, then recording start.
4. Mode:  Record
5. Mode:  Playback
6. Confirm the playback signal recorded in step 3 becomes
adjustable level as follows.
If these levels are not adjustable level, adjust the RV304 (L-
CH) and RV354 (R-CH) on the MAIN  board to repeat steps 4
and 5.
Adjustable level: Playback output of 315 Hz to playback output
of 10 kHz:  
±1.0 dB
Adjustment Location:  MAIN board
REC Level Adjustment
   DECK B
Procedure:
In the MC test mode, the “REC memory mode” is convenient for
this adjustment. In the “REC memory mode” , when the REC starts
the input signal FUNCTION is switched to VIDEO automatically.
When the REC stops, the tape returns near to the recording start
position.
1. Press  MD (VIDEO)  button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck B.
3. After press  REC PAUSE/START  button, press REC PAUSE/
START button, then recording start.
attenuator
set
MD/VIDEO (AUDIO) IN (J101)
1) 315 Hz
2) 10 kHz
50 mV (–23.8 dB)
600 
blank tape
CN-123
AF OSC
+
set
recorded
portion
CN301 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
set
MD/VIDEO (AUDIO) IN (J101) 
315 Hz, 50 mV (–23.8 dB)
blank tape
CS-123
600 
attenuator
AF OSC
+
set
recorded
portion
CN301 (Pin 
3
: L-CH)
(Pin 
1
: R-CH)
level meter
TAPE SPEED
RV1002
RV1001
(NORMAL)  (HIGH)
CN1001
T11
RV11
RV351
RV354
RV304
RV303
RV302
RV301
CN301
CN304
CN302
CN303
1
3
REC LEVEL (L)
(B)
PB LEVEL (L)
(B)
PB LEVEL (L)
(A)
REC BIAS (R)
(B)
REC BIAS (L)
(B)
REC LEVEL (R)
(B)
Page of 68
Display

Click on the first or last page to see other HCD-RG80 service manuals if exist.