DOWNLOAD Sony HCD-LF10 Service Manual ↓ Size: 7.25 MB | Pages: 106 in PDF or view online for FREE

Model
HCD-LF10
Pages
106
Size
7.25 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-lf10.pdf
Date

Sony HCD-LF10 Service Manual ▷ View online

HCD-LF10
21
3-18. BASE  UNIT
3-19. LEVER (BU  LOCK)
4
floating screw
(PTPWHM 2.6)
5
floating screw
(PTPWHM 2.6) 
3
coil spring (holder down A)
6
base unit
1
screw
(BVTP 2.6)
2
lever (CL UP2)
5
three hooks
4
6
lever (BU lock)
1
gear (cap)
2
gear (BU lock)
3
floating screw
(PTPWHM 2.6)
HCD-LF10
22
3-20. CLOSE  LEVER
3-21. DIR  LEVER,  GEAR (IDL-B)
1
washer (3-1-0.4)
2
close lever spring 
4
shaft disc stop
5
close lever 
3
claw
3
puley (gear )
2
nylon washer 1.7
9
DIR lever 
5
gear (IDL-A)
q;
gear (IDL-B)
1
tension coil spring (DIR)
8
stopper
6
Loosen the screw. 
7
Hold the release lever
     and change the direction.
4
gear (cap)
HCD-LF10
23
3-22. GEAR (IDL-C)
6
claw
1
gear (IDL-F)
5
gear loading lever
2
two claws
4
three hooks
3
gear (IDL-D)
7
gear (IDL-C)
24
HCD-LF10
SECTION  4
TEST  MODE
Note 1:
Regarding the notification symbol “R”.
Because the number of the operating buttons of this product
are limited, some operations require use of the operating buttons
of the remote commander (RM-SP320 supplied with the
product). When a specific operation requires use of the
operating buttons of the remote commander (RM-SP320), “R”
is added to the specific operating procedure in this manual.
Example. 
 
MENU/NO “R”
 
 :
The 
[MENU/NO]
 button of remote commander.
Note 2:
Incorrect operations may be performed if the test mode is not
entered properly.
In this case, press the  
I
/1
  button to turn the power off, and
retry to enter the test mode.
1. COLD  RESET
The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning the
set to the customers.
Procedure:
1. Press the  
I
/1
  button to turn the power on.
2. Touch the 
VOL 
  sensor on the touch panel and press the 
Z
button simultaneously for several seconds.
3. The “Cold Reset” display appears for a while, then “Standby”
display blinks, and finally turn the power off (standby mode).
2. DISC  SLOT  LOCK
The disc slot lock function for the antitheft of an demonstration
disc in the store is equipped.
Procedure :
1. Press the  
I
/1
  button to turn the power on.
2. Press the  
FUNCTION “R”
  button or touch the  
FUNCTION
   sensor
on the touch panel to select the “DVD”.
3. Insert a disc.
4. Touch the 
x
 
sensor on the touch panel and press the  
Z
  button
simultaneously for several seconds.
5. The “Locked” display appears for a while and disc cannot be
removed any more even if the 
Z
 button is pressed.
* To release this mode, repeat the above operation. The
“Unlocked” display appears and the disc slot lock mode is
canceled.
Note:
When “Locked” is displayed, the slot lock is not released by turning
power on/off with the  
I/
1
  button.
3. DVD  SHIP  MODE
This mode moves the optical pick-up to the position durable to
vibration. Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press the  
I
/1
  button to turn the power on.
2. Press the  
FUNCTION “R”
  button or touch the  
FUNCTION
  sensor
on the touch panel to select the “DVD”.
3. Remove a disc.
4. Touch the 
sensor on the touch panel and press the 
Z
 button
simultaneously for several seconds with no disc inserted in
the drive.
5. The “Mecha Lock” display appears for a while, then “Standby”
display blinks, and finally turn the power off (standby mode).
* If this operation is performed while the disc is inserted, “Not
In Use” display appears.
4. TEST  MODE
The test mode is prepared in this product. Refer to item 5. TEST
MODE IN for the procedure how to enter the test mode, and to item
6. TEST MODE Advance to advance the test mode menu.
Note:
Be sure to turn off the power of the product after the following test
mode is completed.
TEST MODE MENU
5. TEST  MODE  IN
1. When the product is already disassembled for repair, enter the
test mode as follows. Press the TEST MODE key (S301) inside
the product to enter the TEST MODE.
2. To enter the TEST MODE by the external operation (i.e., to
enter the TEST MODE after the product is already re-
assembled upon completion of repair), touch the seven sensors
on the touch panel in turn while pressing the  
Z
  button.
Note1:
There is a set to which TEST MODE key (S301) is not mounted.
The set in which TEST MODE key (S301) is not mounted enters
the test mode by the external operation.
Moreover, there is an item with the description operated as follows
with the TEST MODE key (S301). The item is done by other
operations that have been described.
Note2:
Using the TEST MODE IN function by the external operation is
available only for the equipment with the production number of
10450 and onward.
6.  TEST  MODE  MENU  ADVANCE
1. Press the TEST MODE key (S301) inside the product to
advance the TEST MODE MENU.
2. If the product is already set in the TEST MODE, the MENU
can be advanced by pressing the  
RETURN 
O
 “R”
  button.
Note:
The MENU advance function using the remote control is available
only for the equipment with the production number of 10450 and
onward.
7. VERSION  INFORMATION
Procedure:
1. Press the TEST MODE key (S301) inside the product or the
RETURN 
O
 “R”
  button.
2. The version is displayed in order of GC, STR, DVD, and
AREA.
Version Information
Key Test Mode
Display Test Mode
AMP Test Volume
Repeat Limit
DVD Service
Product Out
VACS ON/OFF
VACS Display
Touch Sensor Test
Page of 106
Display

Click on the first or last page to see other HCD-LF10 service manuals if exist.