21
3-20. LEVER (DISC SENSOR)/(DISC STOP)
chassis (top)
hole
Install the lever (disc stop) so that the both holes 
are aligned.
hole
1
gear (cap)
3
two claws
5
two hooks
6
lever (disc stop)
lever (disc stop)
4
lever (disc sensor)
PRECAUTION DURING DISC STOP LEVER INSTALLATION
2
gear (IDL-L)
3-21. GEAR (IDL-C)
4
three hooks
2
two claws
6
claw
1
gear (IDL-F)
7
gear (IDL-C)
3
gear (IDL-D)
5
lever (gear loading) assy
22
HCD-IS10
SECTION  4
TEST  MODE
1. TEST  MODES  OTHER  THAN  THE  TEST  MENU
These are executable test mode even if not entering the test menu.
1-1. Cold Reset
The cold reset clears data except DVD data stored in the RAM to
initial conditions. Execute this mode when returning the set to the
customers.
Procedure:
1. In the standby state, the
I
/
1
button on the set is pressed for 5
seconds or more.
2. The messages “MEMORY CLR” and “PUSH POWER” are
displayed on the fluorescent indicator tube.
3. When the
I
/
1
button is pressed in the state of step 2, the
messages “CLEARING” t “CLEARED!” are displayed, then
becomes standby states.
1-2. DVD Version View
Procedure:
1. Connect the set with the TV screen.
2. In the standby state, press the button in order of the [      DISPLAY]
t  [ENTER]  t
I
/
1
on the remote commander, the DVD
version appears on the TV screen.
3. To release from this mode, press the
I
/
1
button.
1-3. Color System Change (Except US, Canadian and
Latin American models)
This mode let you change the color system of the video output from
PAL to NTSC or vice versa.
Procedure:
1. Press the
I
/
1
button to turn the power on.
2. Press the [FUNCTION]  button on the remote commander to
select the “DVD”.
3. Press the [SYSTEM MENU] button on the remote commander.
4. Press the 
 
m
 button on the remote commander to select the
“COLOR SYS”, and press the [  ]  button on the remote
commander.
5. Press the 
 
m
 button on the remote commander to select the
“PAL” or “NTSC”, and press the [  ]  button on the remote
commander.
6. The color system is changed.
1-4. AM Step Change (Except AEP, Russian, UK and
Saudi Arabian models)
The step interval of AM channels can be toggled between 9 kHz
and 10 kHz.
Procedure:
1. Press the
I
/
1
button to turn the power on.
2. Press the [FUNCTION]  button on the remote commander to
select the “AM”.
3. Press the [TUNER MENU] button on the remote commander
and press the 
 
m
 button on the remote commander to select
the “AM step?”, and press the [  ]  button on the remote
commander.
4. The message “10k t  9k” or “9k t  10k” appears on the
fluorescent indicator tube.
5. Press the [  ] button on the remote commander, and the AM
channel step is changed.
1-5. Disc Slot Lock
This mode let you lock the disc slot. When this mode is activated,
the disc will not eject when the  
Z
  button is pressed. The message
“LOCKED” will be displayed on the fluorescent indicator tube.
Procedure:
1. Press the
I
/
1
button to turn the power on.
2. Press the [FUNCTION]  button on the remote commander to
select the “DVD”.
3. Touch the 
x
  sensor and press the 
Z
  button on the set
simultaneously and hold down until “LOCKED” or
“UNLOCKED” displayed on the fluorescent indicator tube
(around 5 seconds).
1-6. Demo Disc Play
Mode to prevent theft of the demonstration disc.
Setting Procedure:
It automatically enters the mode when the demonstration disc is
inserted.
Releasing Procedure:
1. Press the
I
/
1
button to turn the power on.
2. Press the [FUNCTION]  button on the remote commander to
select the “DVD”.
3. Touch the  
x
  and  
 sensor on the set simultaneously and
hold down until “DEMO OFF” displayed on the fluorescent
indicator tube (around 5 seconds).
2. TEST  MODES  IN  THE  TEST  MENU
These are the test modes done in the test menu.
Setting method of the test menu:
1. Press the
I
/
1
button to turn the power on.
2. Press the button in order of the [CLEAR] t [ENTER] t [0]
t [1] t [0] t [ANGLE] on the remote commander. (Make
the interval when each button is pressed within two seconds.)
3. The message “TEST MENU” appears on the fluorescent
indicator tube and enter the test menu.
2-1. Panel Test
Procedure:
1. Enter the test menu.
2. Press the 
 
m
 button on the remote commander to select the
“PANEL TEST”, and press the [ENTER] button on the remote
commander.
3. LEDs (except  
N
 ) and all segments in fluorescent indicator
tube are lighted up. And 
N
  LED and half segments in
fluorescent indicator tube are lighted up, others half segments
in fluorescent indicator tube are lighted up, then LEDs (except
) and all segments in fluorescent indicator tube are lighted
up.  This operation is repeated.
4. When all segments in fluorescent indicator tube are lighted up
in the state of step 3, press the [VOLUME +] button on the remote
commander and model information is displayed on the
fluorescent indicator tube.
Each time the [VOLUME +] button on the remote commander
is pressed, the display changes from destination information,
MC version, SUB version in this order, and returns to the model
information display.
Each time the [VOLUME --] button on the remote commander
is pressed, the version and date are switched.
5. In the state of step 3, press the [FUNCTION]  button on the
remote commander and “K 0” is displayed on the fluorescent
indicator tube.
“K 0” value increases whenever a button on the set is pressed
or a sensor is touched.  However, once a button has been
pressed, it is no longer taken into account.
All buttons on the set are pressed and all sensors are touched,
“OK” and “K 7” are alternately displayed on the fluorescent
indicator tube.
6. To release from this mode, press the
I
/
1
button.
23
HCD-IS10
2-2. AMP Test
The cold reset clears data except DVD data stored in the RAM to
initial conditions. Execute this mode when returning the set to the
customers.
Procedure:
1. Enter the test menu.
2. Press the 
 
m
 button on the remote commander to select the
“AMP TEST”, and press the [ENTER] button on the remote
commander.
3. The message “MEASURE” appears on the fluorescent
indicator tube and enter the AMP test mode.
4. Press the [SUBTITLE] button on the remote commander, the
message “VACS ON” or “VACS OFF” appears on the
fluorescent indicator tube and thus the VACS on/off are
changed.
5. To release from this mode, press the
I
/
1
button.
2-3. Cold Reset
The cold reset clears data except DVD data stored in the RAM to
initial conditions. Execute this mode when returning the set to the
customers.
Procedure:
1. Enter the test menu.
2. Press the 
 
m
 button on the remote commander to select the
“COLD RESET”, and press the [ENTER] button on the remote
commander.
3. The message “COLD RESET.” appears on the fluorescent
indicator tube, then becomes standby states.
2-4. Product Out
Procedure:
1. Enter the test menu.
2. Press the 
 
m
 button on the remote commander to select the
“PRODUCTOUT”, and press the [ENTER] button on the
remote commander.
3. After the “STANDBY” blinking display finishes, the message
“MECHA LOCK” appears on the fluorescent indicator tube
and the ship mode is set.
4. To release from this mode, pull out the power code.
2-5. DVD Service
This mode describes details in “3. DVD SERVICE MODE” (page
24).
2-6. Tuner Factory Preset
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-7. Digital Media Port Test
(Except Latin America model)
Procedure:
1. Connect the DMPORT check jig (P/N: J-2501-309-A) with
the DMPORT jack (CN3802) on the DMB-IVHD board.
2. Press the
I
/1
button to turn the power on.
3. Confirm that both LEDs of the DMPORT check jig lights.
(Confirmation the power supply line)
4. Press the [FUNCTION] button on the remote commander to
select the “DMPORT”.
5. Enter the test menu.
6. Press the 
 
m
 button on the remote commander to select the
“DMPORT CHK”, and press the [ENTER] button on the remote
commander.
7. The message “DMPORT OK.” appears on the fluorescent
indicator tube and enter the digital media port test mode.
(Confirmation of communication line)
When “NO DETECT.” and “UART .TO” are displayed on the
fluorescent indicator tube, confirm the connection of the
DMPORT check jig, and enter the mode again.
Each time the 
 >
  button on the remote commander is pressed,
the connect check and adaptor version check are switched.
Press the 
.
 button on the remote commander, connected
confirmation of the DMPORT check jig is done again.
8. To a pin-jack of the DMPORT check jig input information
relevant to audio signal (sine-wave 1.0 Vrms) and composite
video signal. (white 100% 1.0 Vp-p, color bar, etc.)
9. Confirm the output of speakers and monitor TV. (Confirmation
of analog signal)
10. To release from this mode, press the
I
/1
button.
2-8. VACS Display
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-9. VACS On/off
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-10. DSP Halt Mode
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-11. DSP Status Display
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-12. A.CAL Test  Disp
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-13. Demo Disc Play
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-14. DVD Debug
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-15. Sircs Disable
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
2-16. DMPORT Device Test
Not used for the servicing.
Press the
I
/1
button if having entered this mode.
color
pattern
generator
DMPORT
check jig
(Part No.:
J-2501-309-A)
J001
AF
oscillator
set
(HCD-IS10)
SA-WSIS10
TV
monitor
FL/FR
speaker
DMB-IVHD board
CN3802
SPEAKER board
TB101
IO board
J902
24
HCD-IS10
3. DVD  SERVICE  MODE
3-1. DVD Service Mode General Description
This mode let you make diagnosis and adjustment easily by using
the remote commander and the TV screen. The instructions,
diagnostic results, etc. are given on the on-screen display.
Be sure to execute the IOP measurement when a base unit is replaced.
3-2. Enterring DVD Service Mode
Procedure:
1. Press the
I
/1
button to turn the power on.
2. Press the [FUNCTION]  button on the remote commander to
select the “DVD”.
3. Press the button in order of the [CLEAR] t [ENTER] t [0]
t  [1]  t  [0]  t  [ANGLE]  t  [0]  t  [6]  on the remote
commander. (Make the interval when each button is pressed
within two seconds.)
4. The message “SERVICE IN” appears on the fluorescent
indicator tube and top menu of the Remocon Diagnosis Menu
appears on the on-screen display on the TV screen as follows.
The model name, IF-con version and Syscon version are
displayed at the bottom of the on-screen display.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name :xxxx_xx
IF-con:Ver.xx.xx(xxxx)
Syscon:Ver.x.xxx
5. To execute each function, press its number by using numeric
button on the remote commander.
6. To release from this mode, press the  
I
/1
  button.
3-3. Executing IOP Measurement
In order to execute IOP measurement, the following standard
procedures must be followed.
Procedure:
1. From the top menu of Remocon Diagnosis Menu, select “2
Drive Manual Operation” by pressing the [2]  button on the
remote commander. The following screen appears on the on-
screen display
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging mode
5. MIRR time Adjust
0. Return to Top Menu
2. Select “3. Manual Adjustment” by pressing the [3] button on
the remote commander. The following screen appears on the
on-screen display.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
V
 
v
  Change Value
[RETURN]Return to previous menu
3. Select “6. Iop:” by pressing [6]  button on the remote
commander.
4. Wait until a hexadecimal number appear in the on-screen
display as below.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop: xx
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
V
 
v
  Change Value
[RETURN]Return to previous menu
5. Convert data from hexadecimal to decimal by using conversion
table.
6. If the value is smaller than 93 (decimal), then it is OK. However
if the value is higher than 93, then BU (base unit) is defective
and need to be change.
7. Press the
O
 
RETURN
button on the remote commander to
return to previous menu.
8. Press the [0] button on the remote commander to return to the
top menu of Remocon Diagnosis Menu.
9. Press the  
I
/1
  button to turn off the system.
3-4. Checking Emergency History
To  check the emergency history, please follow the following
procedure.
Procedure:
1.  From the top menu of Remocon Diagnosis Menu, select “3.
Emergency History” by pressing the [3] button on the remote
commander. The following screen appears on the on-screen
display.
Emg. History Check
Laser Hours     CD    999h  59min
                DVD   999h  59min
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
02. 02 02 01 01      00 A9 4B 00
    00 00 00 00      00 00 23 45
[Next]Next page [Prev]Prev page