HCD-GZR77D
17
2-20.  MOTOR (LD)  BOARD
2-19.  MOTOR (TB)  BOARD
5  Remove the two solders of motor.
4  MOTOR (TB) board
2  stopper
2  stopper
6  table motor assy (M741)
table assy
3 two screws
     (+BTTP (M2.6))
1
4  Remove the two solders of motor.
3  MOTOR (LD) board
1  belt (loading)
5  loading motor assy (M751)
2 two screws
     (+BTTP (M2.6))
HCD-GZR77D
18
2-21.  CHASSIS
2-22.  DMB19  BOARD
1 screw
 (+BVTP 
u6)
2 two screws
 (+BVTP 
u8)
3 two screws
 (+BVTP 
u8)
5 chassis
4
9 two screws
 (+BVTP 
u8)
0 two screws
 (+BVTP 
u8)
qs two screws
 (+BVTP 
u8)
qd screw
 
(+BVTP 2.6 (3CR))
2 wire (flat type) (9 core)
 (CN1106)
3 wire (flat type) (7 core)
 (CN1104)
8 wire (flat type) (24 core)
 (CN101)
qf bracket (DMB)
5 wire (flat type) (7 core)
 (CN4602)
1 CN1105 (4P)
4 CN1103 (3P)
6 CN601 (9P)
qa DMB19 board
7 CN201 (6P)
HCD-GZR77D
19
2-24.  OPTICAL  PICK-UP
2-23.  BASE  UNIT
1 screw
 (+PTPWH 
M2.6)
2 base unit
1  two insulator screws
3 two insulators
4 two insulators
2  two insulator screws
5  optical pick-up
6  holder (310)
HCD-GZR77D
20
SECTION  3
TEST  MODE
[COLD RESET]
•  The cold reset clears all data including preset data stored in the 
RAM to initial conditions. Execute this mode when returning 
the set to the customer.
Procedure:
1.  Press the [
?/1
] button to turn on the system. 
2.  Press the [
x
] button, [DISC 3] button and [
?/1
] button 
simultaneously.
3.  The message “COLD RESET” appears on the fl uorescent 
indicator tube. Then, the fl uorescent indicator tube becomes 
blank for a while, and the system is reset. 
[COMMON TEST MODE]
•  This mode is used to check operations of the respective section 
of Equalizer level, volume and VACS ON/OFF.
Procedure:
•  To enter Common Test Mode
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [
x
] button, [PRESET EQ] button and [DISC 1] 
simultaneously.
3.  The message “VACS0” appears on the fl uorescent indicator 
tube.
•  Check of Equalizer Level
1.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “ALL EQ MIN” appears on the fl uorescent indicator 
tube. GEQ decreases to its minimum.
2.  Press the [EQ BAND/MEMORY] button repeatedly until a 
 
message “ALL EQ MAX” appears on the fl uorescent 
indicator tube. GEQ increases to its maximum.
3.  Press the [EQ BAND/MEMORY] button repeatedly until a 
 
message “ALL EQ FLAT” appears on the fl uorescent 
indicator tube. GEQ is set to fl at.
• Check of Volume
1.  Press the [DISPLAY] button repeatedly, the sound volume 
increases to its maximum and message “VOLUME16” t 
“VOLUME MAX” appears on the fl uorescent indicator tube.
2.  Press the [OPTIONS] button repeatedly, the sound volume 
decreases to its minimum and message “VOLUME16” t 
“VOLUME MIN” appears on the fl uorescent indicator tube.
•  Check of VACS (Variable Attenuation Control System)
 ON/OFF 
Select
1.  Press the [REC TO USB] button repeatedly until a message 
“VACS OFF” or “VACS ON” appears on the fl uorescent 
indicator tube.
•  To release from Common Test Mode
1.  To release from this mode, press the [
?/1
] button.
2.  To cold reset is enforced at the same time.
[AMP TEST MODE]
•  This mode is used to display the real time VACS level and 
check operations of the respective sections of Equalizer band 
and DBFB ON/OFF.
Procedure:
•  To enter AMP Test Mode
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [
x
] button, [GROOVE] button and [DISC 1] button 
simultaneously.
3.  The message “AMP TEST IN” appears of the fl uorescent 
indicator tube.
•  Check of VACS Display/AMP Adjustment Select
1.  Press the [REC TO USB] button repeatedly until a message 
 
“V0 0 0” appears on the fl uorescent indicator tube. “0” 
represents VACS level which is triggered by signal level.
2.  Press the [REC TO USB] button repeatedly until a message 
 
“D +4 +0 +2” appears on the fl uorescent indicator tube. “+4” 
represents Equalizer Low level, “+0” represents Equalizer 
Mid level and “+2” represents Equalizer High level.
•  Check of Equalizer Band Select
1.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “LOW +4 dB” appears on the fl uorescent indicator 
tube. EQ Band is set to Low level.
2.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “MID +0 dB” appears on the fl uorescent indicator 
tube. EQ Band is set to Middle level.
3.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “HIGH +2 dB” appears on the fl uorescent indicator 
tube. EQ Band is set to High level.
•  Change of Equalizer Band
1.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “LOW +4 dB” appears on the fl uorescent indicator 
tube. 
2.  When the [OPERATION DIAL] ring is turned clockwise or 
counterclockwise even slightly, “LOW +4 dB” change to 
“LOW –8 dB” y “LOW +8 dB” appears on the fl uorescent 
indicator tube.
3.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “MID +0 dB” appears on the fl uorescent indicator 
tube.
4.  When the [OPERATION DIAL] ring is turned clockwise 
or counterclockwise even slightly, “MID +0 dB” change to 
“MID –8 dB” y “MID +8 dB” appears on the fl uorescent 
indicator tube.
5.  Press the [EQ BAND/MEMORY] button repeatedly until a 
message “HIGH +2 dB” appears on the fl uorescent indicator 
tube.
6.  When the [OPERATION DIAL] ring is turned clockwise or 
counterclockwise even slightly, “HIGH +2 dB” change to 
“HIGH –8 dB” y “HIGH +8 dB” appears on the fl uorescent 
indicator tube.
•  Check of DBFB ON/OFF Select
1.  Press the [OPTIONS] button repeatedly until a message 
“DBFB OFF” or “DBFB ON” appears on the fl uorescent 
indicator tube.
•  To release from AMP Test Mode
1.  To release from this mode, press the [
?/1
] button.
Page of 98
Display

Click on the first or last page to see other HCD-GZR77D / MHC-GZR77D service manuals if exist.