Sony HCD-GZR77D / MHC-GZR77D Service Manual ▷ View online
HCD-GZR77D
17
2-20. MOTOR (LD) BOARD
2-19. MOTOR (TB) BOARD
5 Remove the two solders of motor.
4 MOTOR (TB) board
2 stopper
2 stopper
6 table motor assy (M741)
table assy
3 two screws
(+BTTP (M2.6))
(+BTTP (M2.6))
1
4 Remove the two solders of motor.
3 MOTOR (LD) board
1 belt (loading)
5 loading motor assy (M751)
2 two screws
(+BTTP (M2.6))
(+BTTP (M2.6))
HCD-GZR77D
18
2-21. CHASSIS
2-22. DMB19 BOARD
1 screw
(+BVTP
(+BVTP
3
u6)
2 two screws
(+BVTP
(+BVTP
3
u8)
3 two screws
(+BVTP
(+BVTP
3
u8)
5 chassis
4
9 two screws
(+BVTP
(+BVTP
3
u8)
0 two screws
(+BVTP
(+BVTP
3
u8)
qs two screws
(+BVTP
(+BVTP
3
u8)
qd screw
(+BVTP 2.6 (3CR))
2 wire (flat type) (9 core)
(CN1106)
(CN1106)
3 wire (flat type) (7 core)
(CN1104)
(CN1104)
8 wire (flat type) (24 core)
(CN101)
(CN101)
qf bracket (DMB)
5 wire (flat type) (7 core)
(CN4602)
(CN4602)
1 CN1105 (4P)
4 CN1103 (3P)
6 CN601 (9P)
qa DMB19 board
7 CN201 (6P)
HCD-GZR77D
19
2-24. OPTICAL PICK-UP
2-23. BASE UNIT
1 screw
(+PTPWH
(+PTPWH
M2.6)
2 base unit
1 two insulator screws
3 two insulators
4 two insulators
2 two insulator screws
5 optical pick-up
6 holder (310)
HCD-GZR77D
20
SECTION 3
TEST MODE
[COLD RESET]
• The cold reset clears all data including preset data stored in the
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customer.
the set to the customer.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn on the system.
2. Press the [
x
] button, [DISC 3] button and [
?/1
] button
simultaneously.
3. The message “COLD RESET” appears on the fl uorescent
indicator tube. Then, the fl uorescent indicator tube becomes
blank for a while, and the system is reset.
blank for a while, and the system is reset.
[COMMON TEST MODE]
• This mode is used to check operations of the respective section
• This mode is used to check operations of the respective section
of Equalizer level, volume and VACS ON/OFF.
Procedure:
• To enter Common Test Mode
1. Press the [
• To enter Common Test Mode
1. Press the [
?/1
] button to turn on the system.
2. Press the [
x
] button, [PRESET EQ] button and [DISC 1]
simultaneously.
3. The message “VACS0” appears on the fl uorescent indicator
tube.
• Check of Equalizer Level
1. Press the [EQ BAND/MEMORY] button repeatedly until a
1. Press the [EQ BAND/MEMORY] button repeatedly until a
message “ALL EQ MIN” appears on the fl uorescent indicator
tube. GEQ decreases to its minimum.
tube. GEQ decreases to its minimum.
2. Press the [EQ BAND/MEMORY] button repeatedly until a
message “ALL EQ MAX” appears on the fl uorescent
indicator tube. GEQ increases to its maximum.
indicator tube. GEQ increases to its maximum.
3. Press the [EQ BAND/MEMORY] button repeatedly until a
message “ALL EQ FLAT” appears on the fl uorescent
indicator tube. GEQ is set to fl at.
indicator tube. GEQ is set to fl at.
• Check of Volume
1. Press the [DISPLAY] button repeatedly, the sound volume
1. Press the [DISPLAY] button repeatedly, the sound volume
increases to its maximum and message “VOLUME16” t
“VOLUME MAX” appears on the fl uorescent indicator tube.
2. Press the [OPTIONS] button repeatedly, the sound volume
decreases to its minimum and message “VOLUME16” t
“VOLUME MIN” appears on the fl uorescent indicator tube.
• Check of VACS (Variable Attenuation Control System)
ON/OFF
ON/OFF
Select
1. Press the [REC TO USB] button repeatedly until a message
“VACS OFF” or “VACS ON” appears on the fl uorescent
indicator tube.
indicator tube.
• To release from Common Test Mode
1. To release from this mode, press the [
1. To release from this mode, press the [
?/1
] button.
2. To cold reset is enforced at the same time.
[AMP TEST MODE]
• This mode is used to display the real time VACS level and
• This mode is used to display the real time VACS level and
check operations of the respective sections of Equalizer band
and DBFB ON/OFF.
and DBFB ON/OFF.
Procedure:
• To enter AMP Test Mode
1. Press the [
• To enter AMP Test Mode
1. Press the [
?/1
] button to turn on the system.
2. Press the [
x
] button, [GROOVE] button and [DISC 1] button
simultaneously.
3. The message “AMP TEST IN” appears of the fl uorescent
indicator tube.
• Check of VACS Display/AMP Adjustment Select
1. Press the [REC TO USB] button repeatedly until a message
1. Press the [REC TO USB] button repeatedly until a message
“V0 0 0” appears on the fl uorescent indicator tube. “0”
represents VACS level which is triggered by signal level.
represents VACS level which is triggered by signal level.
2. Press the [REC TO USB] button repeatedly until a message
“D +4 +0 +2” appears on the fl uorescent indicator tube. “+4”
represents Equalizer Low level, “+0” represents Equalizer
Mid level and “+2” represents Equalizer High level.
represents Equalizer Low level, “+0” represents Equalizer
Mid level and “+2” represents Equalizer High level.
• Check of Equalizer Band Select
1. Press the [EQ BAND/MEMORY] button repeatedly until a
1. Press the [EQ BAND/MEMORY] button repeatedly until a
message “LOW +4 dB” appears on the fl uorescent indicator
tube. EQ Band is set to Low level.
tube. EQ Band is set to Low level.
2. Press the [EQ BAND/MEMORY] button repeatedly until a
message “MID +0 dB” appears on the fl uorescent indicator
tube. EQ Band is set to Middle level.
tube. EQ Band is set to Middle level.
3. Press the [EQ BAND/MEMORY] button repeatedly until a
message “HIGH +2 dB” appears on the fl uorescent indicator
tube. EQ Band is set to High level.
tube. EQ Band is set to High level.
• Change of Equalizer Band
1. Press the [EQ BAND/MEMORY] button repeatedly until a
1. Press the [EQ BAND/MEMORY] button repeatedly until a
message “LOW +4 dB” appears on the fl uorescent indicator
tube.
tube.
2. When the [OPERATION DIAL] ring is turned clockwise or
counterclockwise even slightly, “LOW +4 dB” change to
“LOW –8 dB” y “LOW +8 dB” appears on the fl uorescent
“LOW –8 dB” y “LOW +8 dB” appears on the fl uorescent
indicator tube.
3. Press the [EQ BAND/MEMORY] button repeatedly until a
message “MID +0 dB” appears on the fl uorescent indicator
tube.
tube.
4. When the [OPERATION DIAL] ring is turned clockwise
or counterclockwise even slightly, “MID +0 dB” change to
“MID –8 dB” y “MID +8 dB” appears on the fl uorescent
“MID –8 dB” y “MID +8 dB” appears on the fl uorescent
indicator tube.
5. Press the [EQ BAND/MEMORY] button repeatedly until a
message “HIGH +2 dB” appears on the fl uorescent indicator
tube.
tube.
6. When the [OPERATION DIAL] ring is turned clockwise or
counterclockwise even slightly, “HIGH +2 dB” change to
“HIGH –8 dB” y “HIGH +8 dB” appears on the fl uorescent
“HIGH –8 dB” y “HIGH +8 dB” appears on the fl uorescent
indicator tube.
• Check of DBFB ON/OFF Select
1. Press the [OPTIONS] button repeatedly until a message
1. Press the [OPTIONS] button repeatedly until a message
“DBFB OFF” or “DBFB ON” appears on the fl uorescent
indicator tube.
indicator tube.
• To release from AMP Test Mode
1. To release from this mode, press the [
1. To release from this mode, press the [
?/1
] button.
Click on the first or last page to see other HCD-GZR77D / MHC-GZR77D service manuals if exist.