7. Subtract between these two values.
8. If the remainder is smaller than 93 (decimal), then it is
8. If the remainder is smaller than 93 (decimal), then it is
OK. However if the value is higher than 93, then the BU is
defective and need to be change.
defective and need to be change.
9. Press [RETURN] button on the remote commander to return
to previous menu.
10. Press [0] button on the remote commander to return to the
Top Menu of Remocon Diagnosis Menu.
11. Press [
?/1
] button to turn off the system.
• Check Emergency History
To check the emergency history, please follow the following
procedure.
To check the emergency history, please follow the following
procedure.
1. From the Top Menu of Remocon Diagnosis Menu, select “3.
Emergency History” by pressing the [3] button on the remote
commander. The following screen appears on the on-screen
display.
commander. The following screen appears on the on-screen
display.
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page Prev Prev Page
O Return to Top Menu
2. You can check the total time when the laser is turned on
during playback of DVD and CD from the above menu. The
maximum time, which can be displayed are 999h 59min.
maximum time, which can be displayed are 999h 59min.
3. You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page
of emergency history, press [
of emergency history, press [
.
] or [
>
] on the remote
commander. The error code consists of
• Error
Code
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19:
Thermal
shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
52: Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
•
Parameter of error code
This is the detail of error code.
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
•
Time of error code
This is the laser time when an error occurred.
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
HCD-GZR5D
26
To clear the Laser Hour
Press [DISPLAY] button and then press [CLEAR] button. The
data for both CD and DVD data are reset.
Press [DISPLAY] button and then press [CLEAR] button. The
data for both CD and DVD data are reset.
Emg. History Check
1. 01 05 04 04
Laser Hours
CD
0h
0min
DVD
0h
0min
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
Next Next Page Prev Prev Page
O Return to Top Menu
To clear the Emergency History
Press [DVD TOP MENU] button and then press [CLEAR] button.
The error code for all emergency history would be reset.
Press [DVD TOP MENU] button and then press [CLEAR] button.
The error code for all emergency history would be reset.
Emg. History Check
1. 00 00 00 00
Laser Hours
CD
999h
59min
DVD
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
Next Next Page Prev Prev Page
O Return to Top Menu
To clear the Initialize Setup Data
Press [DVD/TUNER MENU] button and then press [CLEAR]
button on the remote commander.
Press [DVD/TUNER MENU] button and then press [CLEAR]
button on the remote commander.
Version information
O Return to Top Menu
Firm (Main) : Ver. xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
To return to the Top Menu of Remocon Diagnosis Menu
Press [0] button on the remote commander.
Press [0] button on the remote commander.
• Check Version Information
To check the version information, please follow the following
procedure.
procedure.
1. From the Top Menu of Remocon Diagnosis Menu, select “4.
Version Information” by pressing the [4] button on the remote
commander. The following screen appears on the on-screen
display.
commander. The following screen appears on the on-screen
display.
Emg. History Check
Initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
Next Next Page Prev Prev Page
O Return to Top Menu
To return to the Top Menu of Remocon Diagnosis Menu,
press [0] on the remote commander.
press [0] on the remote commander.
HCD-GZR5D
27
SECTION 5
MECHANICAL ADJUSTMENTS
• Precaution
1. Clean the following parts with a denatured alcohol-moistened
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer. (Do not bring the head magnetizer close to the
erase head.)
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to
4. After the adjustments, apply suitable locking compound to
the parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
• Torque Measurement
Mode
Torque meter
Meter reading
FWD
CQ-102AS
2.0 – 8.0 mN • m
(20 to 80 g • cm)
(0.28 – 1.12 oz • inch)
FWD
back tension
back tension
CQ-102C
0.15 – 0.6 mN • m
(1.5 to 6 g • cm)
(0.021 – 0.083 oz • inch)
FF
CQ-201AS
5 – 17.7 mN • m
(50 to 177 g • cm)
(0.7 – 2.48 oz • inch)
REW
CQ-201B
5 –17.7 mN • m
(50 to 177 g • cm)
(0.7 – 2.48 oz • inch)
• Tape Tension Measurement
Mode
Torque meter
Meter reading
FWD
CQ-403A
more than 80 g
(more than 2.82 oz)
SECTION 6
ELECTRICAL ADJUSTMENTS
DECK SECTION
Tape
Signal
Used for
P-4-A063
6.3 kHz, – 10 dB
Azimuth Adjustment
0 dB = 0.775V
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
• Test Tape
RECORD/PLAYBACK HEAD AZIMUTH ADJUSTMENT
Procedure:
1. Mode: Playback
Procedure:
1. Mode: Playback
set
JACK board
PHONES jack
(J252)
+
–
level meter
test tape
P-4-A063
(6.3 kHz, -10 dB)
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
so that outputs match within 1dB of peak.
Screw
position
position
L-CH
peak
peak
within
1dB
1dB
Output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
1dB
1dB
Screw
position
position
R-CH
peak
peak
3. Mode: Playback
set
test tape
P-4-A063
(6.3 kHz, -10 dB)
P-4-A063
(6.3 kHz, -10 dB)
oscilloscope
V
H
waveform of oscilloscope
in phase45
90
135
180
good
wrong
JACK board
PHONES jack
(J252)
PHONES jack
(J252)
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
HCD-GZR5D
28
Adjustment Location: Record/Playback/Erase Head
[FM TUNE LEVEL CHECK]
signal
generator
OUTPUT
(75
7)
set
Procedure:
1. Turn on the set.
2. Input the following signal from signal generator to FM
1. Turn on the set.
2. Input the following signal from signal generator to FM
antenna input directly.
Carrier frequency: A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation : 75 kHz
Modulation : 1 kHz
ANT input : 35 dBu (EMF)
Modulation : 1 kHz
ANT input : 35 dBu (EMF)
Note: Use 75 ohm coaxial cable to connect signal generator and
the set.
You cannot use video cable for checking.
Use signal generator whose output impedance is 75 ohm.
3. Set to FM tuner function and tune A, B and C signals.
4. Confi rm “TUNED” is lit on the display for A, B and C sig-
4. Confi rm “TUNED” is lit on the display for A, B and C sig-
nals.
When the selected station signal is received in good condition,
“TUNED” is displayed.
“TUNED” is displayed.
TUNER SECTION