DOWNLOAD Sony HCD-DZ210D Service Manual ↓ Size: 9.28 MB | Pages: 82 in PDF or view online for FREE

Model
HCD-DZ210D
Pages
82
Size
9.28 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-dz210d.pdf
Date

Sony HCD-DZ210D Service Manual ▷ View online

21
HCD-DZ210D
DVD SECTION
[TEST DISC LIST]
Be sure to use the DVD disc that matches the signal standards of
your region.
• 
CD
YEDS-18 (Part No.: 3-702-101-01)
PATD-012 (Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No.: J-6090-069-A)
HLX-504 (Part No.: J-6090-088-A)
PAL    : HLX-506 (Part No.: J-6090-077-A)
• DVD DL (Dual Layer)
NTSC : HLX-501 (Part No.: J-6090-071-A)
HLX-505 (Part No.: J-6090-089-A)
PAL    : HLX-507 (Part No.: J-6090-078-A)
8-1. GENERAL DESCRIPTION
The Mirror Time and IOP measurement allows you to make
diagnosis and adjustment simply by using the remote commander
and monitor TV. The instructions, diagnosis results, etc. are given
on the on-screen display (OSD).
Be sure to execute the Mirror Time and IOP measurement when a
BU (Base Unit) is replaced.
8-2. HOW TO ENTER TEST MODE
While pressing the  
x  
and  A  buttons simultaneously, turn
VOLUME +  with the DVD player in power on.
The Test Mode starts, then the menu shown below will be
displayed on the TV screen.
The menu above is the Remocon Diagnosis Menu screen which
consists of five main functions. At the bottom of the menu screen,
the model name and IF-con version. To enter Mirror Time
Adjustment menu, press button  2 “R”  on the remote commander
to enter Drive Manual Operation menu. To exit from the Test Mode,
press the power button on the remote commander.
8-3. DRIVE MANUAL OPERATION
The Drive Manual Operation menu consists of five main
function. By pressing  2 “R”  button on the remote commander in
the Remocon Diagnosis Menu, the screen will appear as shown.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version Information
Model Name
IF-con
: V
Syscon
: Ver.
er. XX.XX (XXXX)
X.XXX
: DSX1-DAB_ XX
*
1
*1: Changes depending on destination 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
8-4. EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard
procedures must be followed.
(1) In power on, while pressing the  
x  
and  A  buttons
simultaneously, turn   VOLUME +  .
(2) Select “2. Drive Manual Operation” by pressing the  2 “R”
button on the remote commander. The screen will appear as
     shown.
(3) Select “3. Manual Adjustment” by pressing the  3 “R”  button
on the remote commander. The screen will appear as shown.
(4) Select “6.IOP” by pressing the  6 “R”  button on the remote
commander.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
Model Name
IF-con
:  Ver. XX.XX (XXXX)
Syscon
:  Ver. X.XXX
: DSX1-DAB_ XX
*
1
*1: Changes depending on destination 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
o
  O    Change Value
[RETURN] Return to previous menu
22
HCD-DZ210D
(5) Wait until a hexadecimal number appear.
(6) Convert each data from hexadecimal to decimal using
conversion table.
(7) Please find the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
(8) Subtract between these two values.
(9) If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defective
and need to be change.
(10) Press the  RETURN “R”  button to return back to previous
 menu.
(11) Press the  0 “R”  button to return to Top Menu and power off
 the DVD Player.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 5B:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
Change Value
[0] Return to previous menu
8-5. EMERGENCY HISTORY
To  check the emergency history, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “3.
Emergency History Check” by pressing the  3 “R”  button on
the remote commander. The following screen appears on the
on-screen display.
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
(2) You can check the total time when the laser is turned on during
playback of DVD and CD from the above menu. The maximum
time, which can be displayed are 999h 59min.
(3) You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press  . “R”  or  > “R” on the remote
commander. The error code consists of the following three
blocks. The first block indicates the error code. The second
block indicates the parameter and the third block indicates the
time of error code as shown below.
• Error Code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
52: Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
Emg.History Check
1.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
Next   Next Page    Prev  Prev Page
O  Return to Top Menu
23
HCD-DZ210D
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
Example of Error code
1.  01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
• Parameter of error code
This is the detail of error code.
Emg.History Check
1.  01  05  04  04
Laser Hours
CD
0h
0min
DVD
0h
0min
00  92  46  00
00  00  00  00
00  00  23  45
2.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
Next   Next Page    Prev  Prev Page
O  Return to Top Menu
8-5-1.  Clear the Laser Hour
Press  DISPLAY “R”  button and then press  CLEAR “R”  button.
The data for both CD and DVD data are reset.
Emg.History Check
1.  00  00  00  00
Laser Hours
CD
999h
59min
DVD
999h
59min
00  00  00  00
00  00  00  00
00  00  00  00
2.  00  00  00  00
00  00  00  00
00  00  00  00
00  00  00  00
 
Next   Next Page    Prev  Prev Page
O  Return to Top Menu
8-5-2.  Clear the Emergency History
Press  TOP MENU “R”  button and then press  CLEAR “R”  button.
The error code for all emergency history would be reset.
8-5-3.  Clear the Initialize Setup Data
Press  MENU “R”  button and then press  CLEAR “R”  button on
the remote commander.
Version information
 
O  Return to Top Menu
Firm (Main) :  Ver. xxxxx
Firm (Sub) :  xxxxx
RISC :   xxxxx
8032 :   xxxxx
Audio DSP :  xxxxx
Servo DSP :  xxxxx
• Time of error code
This is the laser time when an error occurred.
8-5-4. Return to the Top Menu of Remocon Diagnosis
Menu
Press  0 “R”  button on the remote commander.
• Check Version Information
To  check the version information, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “4.
Version Information” by pressing the  4 “R”  button on the
remote commander. The following screen appears on the on-
screen display.
To return to the Top Menu of Remocon Diagnosis Menu, press
0 “R”  on the remote commander.
24
HCD-DZ210D
SECTION  5
ELECTRICAL ADJUSTMENT
DVD SECTION
When the base unit is replaced, perform the adjustment and the
measurement as shown below in this order.
EXECUTING IOP MEASUREMENT (See page 21)
[TEST DISC LIST]
Be sure to use the DVD disc that matches the signal standards of
your region.
• 
CD
YEDS-18
(Part No.: 3-702-101-01)
PATD-012
(Part No.: 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503
(Part No.: J-6090-069-A)
HLX-504
(Part No.: J-6090-088-A)
PAL    : HLX-506
(Part No.: J-6090-077-A)
• DVD DL (Dual Layer)
NTSC : HLX-501
(Part No.: J-6090-071-A)
HLX-505
(Part No.: J-6090-089-A)
PAL    : HLX-507
(Part No.: J-6090-078-A)
[RF Level Check]
Connection:
Procedure:
1. Connect an oscilloscope to CN1105 pin 6  (RFMON) and
CN1105 pin 3 (GND) on the MAIN board.
2. Turn the power on.
3. Insert the CD test disc (refer to the TEST DISC LIST), and
press the  H  button to play the disc back.
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: 
A clear RF signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
5. Eject the CD disc, and insert the DVD SL test disc (refer to
the TEST DISC LIST), and press the  H   button to play the
disc back.
Checking Location: MAIN board (Side A)
+
CN1105 pin 
6
 (RFMON)
CN1105 pin 
3
 (GND)
oscilloscope 
MAIN board
RF signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:  0.57  to 1.1 Vp-p (CD)
     
0.58 to 1.23 Vp-p (DVD)
IC501
IC1103
3
6
CN1105 Pin 
3
 (GND)
CN1105 Pin 
6
 (RFMON)
CN1105
MAIN BOARD
(SIDE A)
Page of 82
Display