DOWNLOAD Sony HBD-E190 / HBD-E290 / HBD-E490 / HBD-E690 Service Manual ↓ Size: 8.04 MB | Pages: 97 in PDF or view online for FREE

Model
HBD-E190 HBD-E290 HBD-E490 HBD-E690
Pages
97
Size
8.04 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hbd-e190-hbd-e290-hbd-e490-hbd-e690.pdf
Date

Sony HBD-E190 / HBD-E290 / HBD-E490 / HBD-E690 Service Manual ▷ View online

HBD-E190/E290/E490/E690
25
12. Factory Initialize (Factory Settings)
There is a possibility that this mode cannot be correctly execut-
ed. Never use this mode.
13. Network (Network Test Diagnosis Screen: Ifconfi g)
Network menu for the wired ethernet.
Screen 1: Ifconfi g Test
Operation:
[
] Activate Ifconfi g (Display network setting)
[
,] 
Select ping test
[RETURN] Returns to the top menu of the service mode
Screen 2: Ping Test
Operation:
[
<
] Select 
Ifconfi g test
[RETURN]  Returns to the top menu of the service mode
(The details of a Ping test are “14. Network (Network Test Diagno-
sis Screen: Ping)”)
Screen 3: Ifconfi g Test Active
Display Ifconfi g command results.
Operation:
[
] Ifconfi g retry
[
,] Select 
Ping Test
[RETURN]  Returns to the top menu of the service mode
14. Network (Network Test Diagnosis Screen: Ping)
Ping test for the wired ethernet.
Screen 1: Ping Test
Operation:
[
<
] Select 
Ifconfi g test
[
m
Ping execution preparation
[RETURN]  Returns to the top menu of the service mode
Screen 2: The IP address of the Ping point is set up
 
(IP address input mode)
When “Ping to :>” is reversed, the [
] button is pressed and IP 
is inputted.
Operation:
[
Finish to input
[RETURN]  Finish to input
[
<
Finish to input and Select Ifconfi g Test
[0] to [9] 
Input Character sting ‘0-9’
[TIME] 
Input Character sting ‘.’
[CLEAR] Backspace
Screen 3: Ping Test Active
When [START] is reversed, the [
] button is pressed and execute 
ping.
Operation:
[
Activate ping test
[
M
The IP address of the ping point is set up
[RETURN]  Returns to the top menu of the service mode
15. System Information (System Information Display)
This screen displays system information.
Screen 1: Basic Information
Operation:
[
,
Drive information (delta IOP of a drive is measured) 
and wireless device information (not used) displayed 
(go to Screen 2)
[RETURN]  Returns to the top menu of the service mode
Screen 2: Drive and Wireless Information Menu
Operation:
[
<
Basic Information displayed (go to Screen 1)
[RETURN]  Returns to the top menu of the service mode
When delta IOP is measured, it becomes impossible to use the Ver-
sion Up function.
 Network
Test:   
Ifconfig
   Ping
HELP : [DOWN][ENT][(NUM)]
(Screen 1)
 Network
HELP : [DOWN][ENT][(NUM)]
 Network
(Screen 2)
(Screen 3)
Test: Ifconfig   
Ping
[START]
Ping To:
Test:  
Ifconfig
   Ping
IP 192. 168. 11. 2 MAC 00-16-01-85-21-A3
HELP : [ENT]: Re/Exe [RIGHT]
(Screen 1)
Test:
(Screen 2)
Ping
Network
Test: Ifconfig
Ping to :> 192. 168. 200. 13
[ENT] : Release
[RET] : Release
(Screen 3)
 Network
Ping to : 192. 168. 200. 13
[START]
HELP: [ENT] : Start [UP] [LEFT]
Ping
Ifconfig
Ping To :
[START]
 Network
Test: Ifconfig
PING 192. 168. 200. 13 OK!
Ping
HBD-E190/E290/E490/E690
26
Contents List:
Main LSIname
Model
Destination
Sequence Number
MAC
IP
IFCON IFCON 
Version
Bootloader Bootloader 
Version
Host Main 
Host Main Version
MicroBE MicroBE 
Version
Host Sub 
Host Sub Version
Middleware Middleware 
Version
ADSP ADSP 
Version
ADSP Coeff 
ADSP Coeff Version
2nd DSP 
2nd DSP Version (not used)
IF Model
IF Dest
WLAN module Serial
WLAN module hw Version
WLAN module MAC Address
Drive Firm Revision
CD DIOP 
Delta IOP
DVD DIOP 
Delta IOP
BD DIOP 
Delta IOP
CD LD TIME 
LD Time
DVD LD TIME  LD Time
BD LD TIME 
LD Time
 
16. Drive
This menu is used to operate the drive using drive-related diagnos-
tic and tools.
Screen 1: Selecting items under *Drive
Operation:
[
<
]/[
,
]  Selects the category
[
m
]/[
Activate the selected category
[RETURN]  Returns to the top menu of the service mode
[1]  Drive OP data Write
[2]  Servo Parameter Check Menu (Not used)
[3]  Servo Signal Check Menu (Not used)
[4]  S-Curve Check Menu (Not used)
[5]  Readability Check Menu (Not used)
[6]  OP Position Check Menu (Not used)
[7]  OP Check Menu (Not used)
[8]  Load Eject Aging (Not used)
[9]  Spindle Control Check Menu (Not used)
[10] FA Test Mode (Not used)
Screen 2: To start OP data Write
Operation:
[
] Starts
Screen 3: Show OP data Write result
Operation:
NG - USB is not fi nd
OK - OP data write
• Drive 
Test
For drive operating check. Service is only use Drive OP data write 
to rewrite OP data after change of new CPU.
 Drive
[1] Drive OP data Write 
 Drive OP data Write
Insert USB StorageDevice ...
Remove DISC and Close tray.
HELP: [ENT] [RET]
Disc : Load
Mode: 1
(Screen 1)
(Screen 2)
(Screen 3)
HELP: [ENT] [RET]
 Drive OP data Write
Insert USB StorageDevice ...
Remove DISC and Close tray.
NG - USB is not find
OK - OP data write
[ENT] Start
[ENT] Start
 System Information
Sequence Number:
MAC:
IP:
Model: 
Main LSIname: 
Destination:
IF-con Block0 Version:
Bootloader Version:
Host Main Version:
MicroBE Version:
Host Sub Version:
Middleware Version:
ADSP Version:
ADSP Coeff Version:
HELP : [RET] [RIGHT]
(Screen 1)
 System Information
CD DIOP:
DVD DIOP:
WLAN module hw version: 
WLAN module MAC Address: 
Drive Firm Revision:
WLAN module Serial:
IF_MODEL: 
IF_DEST:
BD DIOP:
CD LD TIME:
DVD LD TIME:
BD LD TIME:
HELP : [RET] [LEFT]
(Screen 2)
HBD-E190/E290/E490/E690
27
CONFIRMATION  ITEM
1.  Playback Operation Confi rmation
1-1. Test Disc
Part No.
Description
Layer
J-6090-199-A
BLX-104
Single Layer
J-6090-200-A
BLX-204
Dual Layer
J-2501-307-A
CD (HLX-A1)
J-2501-305-A
HLX-513
Single Layer (NTSC)
J-2501-306-A
HLX-514
Dual Layer (NTSC)
J-6090-077-A
HLX-506
Single Layer (PAL)
J-6090-078-A
HLX-507
Dual Layer (PAL)
Note: Refer to the service manual of BDP-BX1/S350 (Part No. 9-883-
989-1[]) (page 1-3 to 1-14E) for the use of BLX-104/204.
Operation and Display:
1. BLX-104
Procedure:
1. Select 
23.976Hz/1080p.
2.  Play “4.Motion picture”.
3.  Check whether player can play back or not.
4.  Check each outputs.
 Video:
 Composite/S 
Video/component/HDMI.
 Audio:
 Speaker 
out.
*  When 1080/24p monitor is nothing, 1080i (59.94Hz or 50Hz) 
can use instead of 1080/24p.
 
However this is temporary correspondence.
*  When the output of HDMI is 1080p, the signal of Composite/S 
Video/Component are not output.
 
It is necessary to lower the output of HDMI to 1080i or less.
2. BLX-204
Procedure:
1.  Select 1080i (59.94Hz or 50Hz).
2.  Play “4.Motion picture”.
3.  Check whether player can play back or not.
 
(Check the picture and sound output)
3. CD (HLX-A1)
Procedure:
Check whether player can play back or not.
(Check the sound output)
4.  HLX-513/514 (NTSC), HLX-506/507 (PAL)
Procedure:
1.  After displayed Main Menu, select “1.Video Signal”.
2.  Play “1.Color bar 100%”.
 
(Check the picture and sound output)
3.  Return to Menu.
4.  Play “Demonstration 4:3” or “Demonstration 16:9”.
 
(Check the picture and sound output)
1-2.  Playback operation confi rmation
Confi rm operation in each signal/output mode of test disc (BLX-
104/204) according to the content of the repair.
Note: “AV Sync.” doesn’t operate.
2. Networking Confi rmation
Confi rm it according to the following procedure when you confi rm 
the connection of the network.
Note: Do not execute “Network Connection Diagnostics” of “Network 
Settings” of the home menu with only the router connected.
Procedure:
1.  Connect the router with the unit with LAN cable.
2.  Turn on the power of the unit and the router.
3.  Press the [HOME] button on the remote commander, and the 
home menu is displayed.
4. Select 
“Setup” 
 “Network Settings”  “Internet Settings”, 
and press the [
] button on the remote commander.
5.  Select “View Networks Status” and press the [
] button on 
the remote commander.
6. Confi rm IP address are displayed in “IP Address”, “Subnet 
Mask” and “Default Gateway”.
IP Address Setting:
XXXX
Internet Access:
XXXX
Physical Connection:
XXXX
IP Address:
XXX.XXX.XXX.XXX
DNS Settings:
XXXX
MAC Address:
XXX.XXX.XXX.XXX
Primary DNS:
XXX.XXX.XXX.XXX
Secondary DNS:
XXX.XXX.XXX.XXX
Subnet Mask:
XXX.XXX.XXX.XXX
Default Gateway:
XXX.XXX.XXX.XXX
HBD-E190/E290/E490/E690
28
SECTION  4
ELECTRICAL  CHECK
FM  AUTO  STOP  CHECK
Procedure:
1.  Turn the power on.
2.  Input the following signal from Signal Generator to FM an-
tenna input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation 
: 75 kHz
Modulation 
: 1 kHz
ANT input 
: 35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the set. You 
cannot use video cable for checking.
 
  Please use SG whose output impedance is 75 ohm. 
 
3.  Set to FM tuner function and scan the input FM signal with 
automatic scanning.
4. Confi rm that input Frequency of A, B and C detected and auto-
matic scanning stops.
 
The stop of automatic scanning means “The station signal is re-
ceived in good condition”.
generator
SET
+
75 
:
Page of 97
Display

Click on the first or last page to see other HBD-E190 / HBD-E290 / HBD-E490 / HBD-E690 service manuals if exist.