Sony DAV-SZ1000W / HBD-SZ1000W (serv.man2) Service Manual ▷ View online
1. The FLUORESCENT INDICATOR TUBE DRIVER(IC501) outputs signal for the
FLUORESCENT INDICATOR TUBE(ND501) to operate by the control signal from
the SYSTEM CONTROL(IC5002).
the SYSTEM CONTROL(IC5002).
2. Voltage required for the FLUORESCENT INDICATOR TUBE operation is supplied
g
q
p
pp
from the DC/DC CONVERTER(T501).
3. The LED lights up by the signals from the SYSTEM CONTROL(IC5002) and the
FLUORESCENT INDICATOR TUBE DRIVER(IC501).
(Note) How to check if it started properly.
•
When the SYSTEM CONTROL(IC5002) boots up properly, “DEMO” will be
indicated on the display of the main unit. If “DEMO” is not displayed, you need to
check the power input signal to the SYSTEM CONTROL(IC5002).
indicated on the display of the main unit. If “DEMO” is not displayed, you need to
check the power input signal to the SYSTEM CONTROL(IC5002).
9
Page
1. When AC power supplies voltage to the SUB POWER TRANSFORMAER(T903),
FAN14V output signal is output. This signal is input to the FAN
DRIVE(Q3000,Q3002) and then the DC FAN(FAN3001) starts spinning at low
speed.
DRIVE(Q3000,Q3002) and then the DC FAN(FAN3001) starts spinning at low
speed.
2. When the SUB WOOFER outputs in high volume, the signal is input to the FAN
DRIVE(Q3000,Q3002) and the DC FAN(FAN3001) starts spinning at high
speed.(Refer to P.18)
speed.(Refer to P.18)
(Note) Spinning of the fan
If th DC FAN d
t
i
th t
t
i
id th
it
ill i
Thi
•
If the DC FAN dose not spin, the temperature inside the unit will increase. This
may cause the unit to stop operating along with the display “Protector” on the
FLUORESCENT INDICATOR TUBE.
may cause the unit to stop operating along with the display “Protector” on the
FLUORESCENT INDICATOR TUBE.
10
Page
1.
When AC cord is pulled out, AC and DC voltage for the SYSTEM CONTROL
decrease.
decrease.
2.
The SYSTEM CONTROL(IC5002 20pin) detects and outputs this decrease of
the DC voltage.
the DC voltage.
g
3.
When the SYSTEM CONTROL(IC5002 20pin) detects AC_CUT signal, it enters
to shut-down operation and saves the backup data in IC. The data such as tuner
setting, sound field, volume and speaker settings are stored as backups.
to shut-down operation and saves the backup data in IC. The data such as tuner
setting, sound field, volume and speaker settings are stored as backups.
11
Page
Following are descriptions of the SERVO section.