DOWNLOAD Sony CMT-SE9 / MDS-SE9 Service Manual ↓ Size: 6.94 MB | Pages: 77 in PDF or view online for FREE

Model
CMT-SE9 MDS-SE9
Pages
77
Size
6.94 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cmt-se9-mds-se9.pdf
Date

Sony CMT-SE9 / MDS-SE9 Service Manual ▷ View online

29
MDS-SE9
Record Bias Adjustment
Procedure :
1. Press the [FUNCTION] button to select TAPE. (HCD-SE9)
2. Insert a tape into deck, press the [TAPE REC] button, and then
press the  
TAPE
 X  button to start recording.
3. Mode : Record
4. Mode : Playback
5. Confirm playback the signal recorded in step  become adjustment
level as follows
If these levels do not satisfy adjustment level, adjust the RV241
(L-CH) and RV291 (R-CH) on the MAIN board to repeat steps
3 and 4.
Adjustment level : The playback output of 10kHz level difference
against 315Hz reference should be 0 
±
 3.0dB.
Adjustment Location :
[MAIN BOARD](SIDE B)
AF OSC
1) 315 Hz
2) 10 kHz
blank tape
CS-123
set
attenuator
600 
50 mV (–23.8 dB)
MD/TAPE OUT   (J401)
recorded
position
level meter
set
MD/TAPE OUT   (J401)
Tape speed Adjust 
RV321
RV291
Record Bias Adjust (R-CH)
RV241
Record Bias Adjust (L-CH)
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: REC/PB Head
Tape Speed Check
Procedure:
1.
MODE : FWD Playback.
2.
Insert the WS-48B into deck.
3.
Press the  
TAPE
 Y  button of deck.
4.
Check the reading of frequency counter becomes 3000 ± 90
Hz. If these level do not satisfy adjustment level, adjust the
RV321.
Adjustment Location: MAIN BOARD
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.35%
(test tape: WS-48B)
3.
Mode: Playback
test tape
P-4-A100
(10kHz, –10dB)
oscilloscope
set
Waveform of oscilloscope
in phase
45
°
90
°
135
°
180
°
good
wrong
V
H
R-ch
L-ch
GND
R-CH
MD/TAPE OUT   (J401)
L-CH
test tape
WS-48B
(3kHz, 0dB)
frequency
counter
set
MD/TAPE OUT   (J401)
30
MDS-SE9
Other faults are suspected.
Check the mechanism parts (spindle motor, sled motor, etc.).
Start
NG
NG
NG
OK
OK
OK
Laser Power Check
6-2.
(See page 33)
6-3.
(See page 33)
6-4.
(See page 34)
Iop Compare
Auto Check
Replace optical pick-up or MDM-7S2D
MD SECTION
1. Parts  Replacement  and  Adjustment
If malfunctions caused by optical pick-up such as sound skipping are suspected, follow the following check.
Check before replacement
31
MDS-SE9
Flow Chart for Adjustment
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Start
IC195 replacement
OP or IC195 replacement
IC101, IC195 or D101 
replacement
OP, IC993 or IC195 
replacement
After turning the power off and on, initialises the non-volatile 
memory (EEPROM).
7. Initial setting of adjustment value (See page 36)
9. Temperature compensation offset adjustment (See page 36)
10. Laser power adjustment (See page 36)
OP, IC701, IC933 or IC195 
replacement
OP, IC101, IC201 or IC195 
replacement
OP replacement
Spindle motor replacement
6-4. Auto check (See page 34)
End
11. Iop NV save (See page 37)
12.Traverse adjustment (See page 37)
13. Focus bias adjustment (See page 38)
16. Auto gain control output level adjustment (See page 39)
In Err display mode, write OP change Iop
In Err display mode, Spdl change
•Abbreviation
OP: Optical pick-up
32
MDS-SE9
2.
Precautions for Checking Laser Diode
Emission
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
3.
Precautions for Use of Optical Pick-Up
(KMS-262A/262E)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when handling it.
Before disconnecting the connector, perform soldering bridge to the
laser tap. Before connecting the connector, be careful not to remove
the solder. Also take adequate measures to prevent damage by static
electricity. Handle the flexible board with care as it breaks easily.
Optical pick-up flexible board
pick-up
flexible board
laser tap
4. Precautions for Adjustments
1. When replacing the following parts, perform the adjustments
and checks with 
 in the order shown in the following table.
2. Set the MD test mode when performing adjustments.
After completing the adjustments, exit the MD test mode.
Perform the adjustments and checks in “Group Service” of the
MD test mode.
3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring devices.
Check Disc (TDYS-1) (Part No. : 4-963-646-01)
Test Disk (MDW-74/GA-1) (Part No. : 4-229-747-01)
Laser power meter LPM-8001 (Part No. : J-2501-046-A)
or
MD Laser power meter 8010S (Part No. :  J-2501-145-A)*
1
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
(Part No. : J-2501-196-A)
5. When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the
oscilloscope.
(VC and ground will become short-circuited.)
6. Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Notes on page 11)
7. As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
*
1
Laser power meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (Part
No. J-2501-145-A) instead of the conventional laser power
meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of optical pick-up.
7.
Initial setting of adjustment value
8.
Recording of Iop information
9.
Temperature compensation
offset adjustment
10. Laser power adjustment
11. Iop NV Save
12. Traverse adjustment
13. Focus bias adjustment
16. Auto gain adjustment
6-4. AUTO CHECK
Optical
Pick-up
IC101
IC701
IC201
IC993
IC195
D101
Parts to be replaced
Adjustment
Before starting adjustment:
The adjustment value differs depending on the types (KMS-262A
or KMS-262E) of optical pickup. Be sure to confirm the type name
before starting adjustment.
pink
: KMS-262A
white : KMS-262E
UV adhesive = 
UV adhesive 
Optical pick-up
(KMS-262A/262E)
Page of 77
Display

Click on the first or last page to see other CMT-SE9 / MDS-SE9 service manuals if exist.