DOWNLOAD Sony CMT-SE9 / MDS-SE9 Service Manual ↓ Size: 6.94 MB | Pages: 77 in PDF or view online for FREE

Model
CMT-SE9 MDS-SE9
Pages
77
Size
6.94 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cmt-se9-mds-se9.pdf
Date

Sony CMT-SE9 / MDS-SE9 Service Manual ▷ View online

25
MDS-SE9
5. Key Test Mode
Procedure:
1.
Press the  ?/1  button to turn on the power.(HCD-SE9)
2.
Press three bottons  Z 
TAPE
  ,  
TAPE 
X  and  
TAPE 
x  simultaneously, and  be in the state of version test mode.
Press [TAPE DIRECTION] button to select the key test mode.
3.
In the key test mode, the LCD displays “KEY 1”. Each time a button is pressed, “KEY #” value increases. However, once a button is
pressed, it is no longer taken into account. It is end at “KEY 19 OK”.
4.
To exit from this mode, press the  ?/1  button. (HCD-SE9)
5. Selecting the Test Mode
There are 26 types of test modes as shown below. The groups can be switched by pressing the  
MD 
.
or  
MD 
>
  button. After selecting
the group to be used, press the [ENTER/START]
 
button. After setting a certain group, pressing the  
MD 
.
or  
MD 
>
  button switches
modes shown below.
Refer to “Group” in the table for details can be selected.
All items used for servicing can be treated using group [Service]. So be carefully not to enter other groups by mistake.
Note:
Do not use the test mode in the [Develop] group.
If used, the unit may not operate normally.
If the [Develop] group is set accidentally, press the [MODE] button immediately to exit the [Develop] group.
MD  TEST MODE
1. Precautions For Use of Test Mode
• As operations related to loading will be performed regardless of the test mode operations being performed, be sure to check that the disc
is stopped before setting and removing it.
Even if the  Z 
MD
  button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc will not
stop rotating.
Therefore, it will be ejected while rotating.
Be sure to press the  Z 
MD
  button after pressing the [MODE] button and the rotation of disc is stopped.
1-1. Recording Laser Emission Mode and Operating Buttons
• Continuous recording mode (CREC 2MODE) (C37)
• Laser power check mode (LDPWR CHECK) (C13)
• Laser power adjustment mode (LDPWR ADJUST) (C04)
• Comparison with initial Iop value written in nonvolatile memory (Iop Compare) (C27)
• Write current Iop value in read nonvolatile memory using microprocessor (Iop NV Save) (C06)
• Traverse (MO) check (EF MO CHECK) (C14)
• Traverse (MO) adjustment (EF MO ADJUST) (C07)
• When pressing the [REC/REC IT] button.
2. Setting the Test Mode
Procedure : 1. Press the ?/1 button to turn the power on. (HCD-SE9)
2. Press the [FUNCTION] button to enter “MD” mode. (HCD-SE9)
3. Press three buttons of  
MD
 x , [REC MODE] and  Z 
MD
  simultaneously.
When the test mode is set, “[Check]” will be displayed. Pressing the 
MD 
.  or  
MD 
> button between the
following three groups; ···
Tt [Check] Tt [Service] Tt [Develop] Tt ···.
Note:
Do not use the test mode in the [Develop] group.
If used, the unit may not operate normally.
If the [Develop] group is set accidentally, press the [MODE] button immediately to exit the [Develop] group.
3. Releasing the Test Mode
Press the  Z 
TAPE
  button once and press the  ?
/
1  button to turn the power off, the set goes to the standby mode.
4. Basic Operations of the Test Mode
All operations are performed using the  
MD
 
.
 ,  
MD
 
>
 , [ENTER/START], [MODE] and [TAPE REC] buttons.
The functions of these buttons are as follows.
Function name
Function
[ENTER/START]
 
button
Proceeds onto the next step. Finalizes input
[MODE]
 
button
Returns to previous step. Stops operations
 
MD
 . ,
MD
 > buttons
Changes parameters and modes
[TAPE REC]
 
button
Selects the sub menu
26
MDS-SE9
• For details of each adjustment mode, refer to “SECTION 6  ELECTRICAL ADJUSTMENTS”.
About “Err Display” (C02), please refer to a page 7 self-diagnostic function.
• If a different mode has been selected by mistake, press the
 
[MODE]
 
button to release that mode.
• Modes with (
×
) in the Mark column are not used for servicing and therefore are not described in detail. If these modes are set acciden-
tally, press the
 
[MODE]
 
button to release the mode immediately.
5-1. Operating the Continuous Playback Mode
1.
Entering the continuous playback mode
(1) Set the disc in the unit. (Whichever recordable discs or discs for playback only are available)
(2) Press the  
MD
 .  or  
MD
 >  button to display “CPLAY 2MODE” (C36).
(3) Press the [ENTER/START] button to change the display to “CPLAY2MID”.
(4) When access completes, the display changes to “C = 
 AD = 
 )”.
Note: The numbers “   ” on the display show you error rates and ADER.
2.
Changing the parts to be played back
(1) Press the [ENTER/START] button during continuous playback to change the display as below.
When pressed another time, the parts to be played back can be moved.
(2) When access completes, the display changes to “C = 
 AD = 
 )”.
Note: The numbers “   ” on the display show you error rates and ADER.
3.
Ending the continuous playback mode
(1) Press the [MODE] button. The display will change to “CPLAY 2MODE” (C36).
(2) Press the  Z 
MD
  button and take out the disc.
Note : The playback start addresses for IN, MID, and OUT are as follows.
IN
: 40h cluster
MID
: 300h cluster
OUT
: 700h cluster
Display
AUTO CHECK
Err Display
TEMP ADJUST
LDPWR ADJUST
Iop Write
Iop NV Save
EF MO ADJUST
EF CD ADJUST
FBIAS ADJUST
AG Set (MO)
AG Set (CD)
TEMP CHECK
LDPWR CHECK
EF MO CHECK
EF CD CHECK
FBIAS CHECK
ScurveCHECK
VERIFYMODE
DETRK CHECK
0920 CHECK
Iop Read
Iop Compare
ADJ CLEAR
INFORMATION
CPLAY 2MODE
CREC 2MODE
Details
Automatic self-diagnosis
Error history display, clear
Temperature compensation offset adjustment
Laser power adjustment
Iop data writing
Writes current Iop value in read nonvolatile memory using microprocessor
Traverse (MO) adjustment
Traverse (CD) adjustment
Focus bias adjustment
Auto gain output level adjustment (MO)
Auto gain output level adjustment (CD)
Temperature compensation offset check
Laser power check
Traverse (MO) check
Traverse (CD) check
Focus bias check
S-curve check
Nonvolatile memory check
Detrack check
Most circumference check
Iop data display
Comparison with initial Iop value written in nonvolatile memory
Initialization of nonvolatile memory for adjustment values
Display of microprocessor version, etc.
Continuous playback mode
Continuous recording mode
No.
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C25
C26
C27
C28
C31
C36
C37
Mark
Group
Check
Service
“CPLAY 2MID” 
t “CPLAY 2OUT” t “CPLAY 2IN”  
27
MDS-SE9
5-2. Operating the Continuous Recording Mode
 (Use only when performing self-recording/playback check)
1.
Entering the continuous recording mode
(1) Set a recordable disc in the unit.
(2) Press the  
MD
 .  or  
MD
 >  button to display “CREC
 
2MODE” (C37).
(3) Press the [ENTER/START] button to change the display to “CREC 2MID
.
(4) When access completes, the display changes to “CREC 2( 
 )” and “
           
” lights up.
Note: The numbers “   ” on the displayed show you the recording position addresses.
2.
Changing the parts to be recorded
(1) When the [ENTER/START] button is pressed during continuous recording, the display changes as below.
When pressed another time, the parts to be recorded can be changed. “ 
          
” goes off.
(2) When access completes, the display changes to “CREC 2( 
 )” and “ 
          
” lights up.
Note: The numbers “   ” on the display show you the recording position addresses.
3.
Ending the continuous recording mode
(1) Press the [MODE] button. The display changes to “CREC 2MODE” (C37) and “ 
          
”  goes off.
(2) Press the  Z 
MD
  button and take out the disc.
Note 1 : The recording start addresses for IN, MID, and OUT are as follows.
IN
: 40h cluster
MID
: 300h cluster
OUT
: 700h cluster
Note 2 : The [MODE] button can be used to stop recording anytime.
Note 3 : Do not perform continuous recording for long periods of time above 5 minutes.
Note 4 : During continuous recording, be careful not to apply vibration.
7. Automatic Self-diagnosis Function
This test mode performs CREC and CPLAY automatically for mainly checking the characteristics of the optical pick-up.
To perform this test mode, the laser power must first be checked.
Perform AUTO CHECK after the laser power check and Iop Compare.
Procedure:
1.
Display “AUTO CHECK” and press the [ENTER/START] button. If “LDPWR 
 ” is displayed, it means that the laser power
check has not been performed. In this case, perform the laser power check and Iop Compare (C27), and then repeat from step1.
2.
If a disc is in the mechanical deck, it will be ejected forcibly.
“DISC IN” will be displayed in this case. Load a test disc (MDW-74/GA-1) which can be recorded.
3.
If a disc is loaded at step 2, the check will start automatically.
4.
When “XX CHECK” is displayed, the item corresponding to XX will be performed.
When “06 CHECK” completes, the disc loaded at step 2 will be ejected. “DISC IN” will be displayed. Load the check disc (TDYS-1).
5.
When the disc is loaded in step 4, the check will automatically be resumed from “07 CHECK”.
6.
After completing to “0C CHECK”, check OK or NG will be displayed. If all items are OK, “CHK ALL OK” will be displayed. If any
item is NG, it will be displayed as “NG:xxxx”.
When “CHK ALL OK” is displayed, it means that the optical pick-up is normal. Check the operations of other parts (spindle motor, sled
motor, etc.).
When displayed as “NG:xxxx”, it means that the optical pick-up is faulty. In this case, replace the optical pick-up.
6. Functions of Other Buttons
“CREC 2MID” 
t “CREC 2OUT” t “CREC 2IN”  
REC
REC
REC
REC
Function
MD
 N X
MD
 x
TAPE
 M
TAPE
 m
TAPE DIRECTION
REC MODE
MD
TAPE
TAPE
 X
REC/REC IT
DISPLAY
Contents
Sets continuous playback when this is pressed in the STOP state. When this is pressed during
continuous playback, tracking power servo turns ON/OFF.
Stops continuous playback and continuous recording
The sled moves to the outer circumference only when this is pressed
The sled moves to the inner circumference only when this is pressed
Switches the spindle servo mode (CLV S 
↔ 
CLV A)
Switches the pits or grooves each time the button is pressed
Ejects the disc
Releases the test mode
Clears the setting of pits and groove, and judges pits and groove again.
When it is pressed while servo is turning on, the recording starts from present position.
Switches the display mode
28
MDS-SE9
Record/Playback Head Azimuth Adjustment
Procedure:
1.
Mode : Playback
2.
Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1 dB of peak.
L-CH peak
R-CH peak
screw position
output
level
within
1 dB
L-CH peak
R-CH peak
screw position
within 1dB
TAPE SECTION
0 dB=0.775V
1.
Demagnetize the record/playback head with a head demagne-
tizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
4.
The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit ad-
justment.)
5.
The adjustments should be performed for both L-CH and R-
CH.
6.
Switches and controls should be set as follows unless other-
wise specified.
test tape
P-4-A100
(10kHz, –10dB)
level meter
set
+
MD/TAPE OUT   (J401)
Tape
P-4-A100
WS-48B
10 kHz, –10 dB
3 kHz, 0 dB
Azimuth Adjustment
Tape Speed Adjustment
Signal
Used for
SECTION 6
ELECTRICAL ADJUSTMENTS
SECTION  5
MECHANICAL ADJUSTMENTS
PRECAUTION
1.
Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback head pinch roller
erase head rubber belts
capstan
2.
Demagnetize the record/playback head with a head demagne-
tizer.
(Do not bring the head demagnetizer close to the erase head.)
3.
Do not use a magnetized screwdriver for the adjustments.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Torque
Torque Meter
Meter Reading
FWD
CQ-102C
2.94 to 7.74mN •m
(30 to 79g •cm)
FWD
CQ- 102C
0.20 to 0.59mN •m
back tension
(2 to 6g •cm)
REV
CQ- 102RC
2.94 to 7.74mN •m
(30 to 79g •cm)
REV
CQ-102RC
0.20 to 0.59mN •m
back tension
(2 to 6g •cm)
FF,REW
CQ- 201B
6.86 to 17.64mN •m
(70 to 179g •cm)
FWD
CQ-403A
9.80mN •m or more
tension
(100g •cm or more)
REV
CQ-403R
9.80mN •m or more
tension
(100g •cm or more)
tape mechanism deck
adjustment screw
Page of 77