33
HCD-SE5/SE9
2-7.  Disc Check Memory
Disc Check Memory
 1. SL Disc check
 2. CD Disc check
 3. DL Disc check
Exit: RETURN
On this screen, measure the mirror time of chucked disc, and write
to the EEPROM.
2-8.  Error Rate Display
Error Rate Display
UC
CR
Address
PI1 Err
Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx
PI2 Err
Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx
PO  Err
Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx
Exit: RETURN
On this screen, measure and display the error rate.
UC : Incorrect value
CR : Correct value
Add : Address
2-9.  SACD Water Mark Check
SACD Water Mark Check
 PSP AMP
 PSN
 Start: ENTER
Stop: RETURN
On this screen, measure the PSP AMP value and PSN value of SACD
water mark.
3.
MECHA AGING
On the Test Mode Menu screen, selecting 
[3]
 displays the aging
test menu.
Note:
 MECHA AGING is not available in this set.
### Aging Test MENU ###
**
 Pls use over 40min. CD 
**
Operation Menu
1. Open/Close Test
Exit: RETURN
4.
EMERGENCY  HISTORY
On the Test Mode Menu screen, selecting 
[4]
  displays the
information such as servo emergency history.
The history information from last 1 up to 10 can be scrolled with
the v key or V key. Also, specific information can be displayed
by directly entering that number with ten keys.
### EMG. History ###
  Laser Hours
CD
xxxxhxxm
DVD
xxxxhxxm
a.
bb xx xx xx  xx xx xx xx
xx xx xx xx  xx xx xx xx
a.
bb xx xx xx  xx xx xx xx
xx xx xx xx  xx xx xx xx
   Select:1-9
Scroll:UP/DOWN
  (1.Latest EMG.)
Exit: RETURN
xxxxhxxm : The laser on total hours. Data below minutes are
omitted.
a.
: Error number.
bb
: Error code.
xx
: Not used.
• Clearing History Information
Clearing laser hours:
Press the 
[DVD DISPLAY]
 and 
[CLEAR]
 keys in this order.
Then both CD and DVD data are cleared.
Clearing emergency history:
Press the 
[TOP MENU]
 and 
[CLEAR]
 keys in this order.
Initializing set up data:
Press 
[DVD MENU]
 and 
[CLEAR]
 keys in this order.
The data have been initialized when “EEPROM Initialize
Finished.”  message is displayed. The EMG. History screen will
be restored soon.
34
HCD-SE5/SE9
• Code list of Emergency History
10: Communication to RF AMP (IC001) failed.
11: Each servo for focus, tracking, and spindle is unlocked.
12: Check sum error of EEPROM (IC204).
14: Communication to servo DSP (IC509) failed, or servo DSP
(IC509) is faulty.
15: Communication to DVD decoder (IC701) failed, or DVD
decoder (IC701) is faulty.
16: Communication to DSD decoder (IC801) failed, or DSD
decoder (IC801) is faulty.
20: Initialization of sled servo failed. It is not placed in the ini-
tial position.
23: Sled servo operation error.
24: Made a request to move the sled servo to wrong position.
30: Tracking balance adjustment error.
31: Tracking gain adjustment error.
33: Focus bias adjustment error.
34: Focus gain adjustment error.
35: Equalizer adjustment error.
40: Focus servo does not operate.
41: With a DVD dual layer disc, focus jump failed.
50: CLV (spindle) servo does not operate.
51: Spindle does not stop.
60: Made a request to seek nonexistent address.
61: Seek error of retry more than regulated times.
70: Control data could not be read.
80: Disc reading failed.
5.
MECHA  ERROR  HISTORY
On the Test Mode Menu screen, selecting 
[5]
 displays the information
of mechanism deck error history.
The history information from last 1 up to 8 can be scrolled with
the v key or V key. Also, specific information can be displayed
by directly entering that number with ten keys.
### Mecha Error History ###
  1. aa bb cc xx xx xx xx xx
  2. aa bb cc xx xx xx xx xx
  3. aa bb cc xx xx xx xx xx
  4. aa bb cc xx xx xx xx xx
  5. aa bb cc xx xx xx xx xx
  6. aa bb cc xx xx xx xx xx
  7. aa bb cc xx xx xx xx xx
  8. aa bb cc xx xx xx xx xx
Scroll:UP/DOWN
(1.Latest Err.)
Exit: RETURN
aa: Initialization is completed or not.
FF
: Complete.
other number : Not complete.
bb: Operating status of mechanism deck at an error occurred.
(lod sq jcp)
00
: Initializing.
10 to 15 : Open operating.
16 to 19 : Kicking cause open failed.
1A to 1F : Open operating.
20 to 27 : Complete the open operation.
28
: No disc and complete the open operation.
29 to 2F : Complete the open operation.
30 to 3F : Close requesting.
40 to 4F : Open requesting.
50 to 5F : Close operating.
60 to 6F : Complete the chucking operation.
80 to 8F : Complete the release operation.
(BU is home position)
90 to 9F : BU down operating.
A0 to AF : Opening/closing the shutter. Or stationary state in
open/close the shutter is enablement.
B0 to BF : BU up requesting.
C0 to CF : BU down requesting.
D0 to DF : BU upping.
E0 to EF : No disc checking in disc loading.
cc: Operating status of mechanism deck at an error occurred.
(lod oq jcp)
00
: Complete the operation.
10 to 1F : Open operating.
20 to 2F : Close operating.
30 to 3F : Release operating.
60 to 6F : Chucking operating.
70 to 7F : Kicking operating.
80 to 8F : Returning the BU to home position. (after kicking)
35
HCD-SE5/SE9
6.
VERSION  INFORMATION
On the Test Mode Menu screen, selecting 
[6]
 displays the ROM
version and region code.
The parenthesized hexadecimal number in version field is checksum
value of ROM.
## Version Information ##
 IF con.
Ver.x. xx
 SYScon.
Ver.x. xx  (xxxx)
Model
CMT-SE5 or CMT-SE9
Region
0x
Config
xxxxxxxx
 Front End Ver.x.xx
Exit: RETURN
IF con.
: The version of system controller (IC501).
SYScon. : The version of DVD system processor (IC207).
Front End: The version of mechanism controller (IC901).
7.
VIDEO  LEVEL  ADJUSTMENT
On the Test Mode Menu screen, selecting 
[7]
 displays color bars
for video level adjustment. During display of color bars, OSD
disappears but the menu screen will be restored if pressing the
[RETURN      ]
 key.
O
36
HCD-SE5/SE9
 DVD SECTION
AUTO SERVO ADJUSTMENT
After parts related to the servo circuit (RF amplifier (IC001), DSP
(IC509), motor driver (IC501), EEPROM (IC903) so on) are
replaced, re-adjusting the servo circuit is necessary. Select “ALL”
at  “1. DRIVE AUTO ADJUSTMENT” (Refer to page XX in TEST
MODE) and adjust DVD-SL (single layer), CD and DVD-DL (dual
layer).
[TEST DISC LIST]
Use the following test disc on test mode.
TDV-520CSO (DVD-SL): PART No. J-2501-236-A
LUV-P01 (CD):
PART No. 4-999-032-01
TDV-540C (DVD-DL):
PART No. J-2501-235-A
Note:
Do not use exiting test disc for DVD.
SECTION  5
ELECTRICAL  ADJUSTMENT
       RFMON signal waveform
• Standard value
Test Disc
RFMON level
Standard Value
DVD
TDV-520CSO
1.09 
±
 0.2Vp-p
(J-2501-236-A)
CD
LUV-P01
1.05 
±
 0.2Vp-p
(4-999-032-01)
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
RFMON level
RFMON Level Check
Perform a RFMON level check before exchanging optical pick-up.
Measurement Point: DMBSE board CN901
1pin (RF) — 3pin (GND)
Ver 1.1