Sony CMT-F3MD / HCD-F3MD Service Manual ▷ View online
73
Pin No.
Pin Name
I/O
Description
89
FRDR
O
Focus servo drive PWM signal (–) output to the BH6511FS (IC152)
90
FS4
O
Clock signal (176.4 kHz) output terminal (X’tal system) Not used (open)
91
SRDR
O
Sled servo drive PWM signal (–) output to the BH6511FS (IC152)
92
SFDR
O
Sled servo drive PWM signal (+) output to the BH6511FS (IC152)
93
SPRD
O
Spindle servo drive PWM signal (–) output to the BH6511FS (IC152)
94
SPFD
O
Spindle servo drive PWM signal (+) output to the BH6511FS (IC152)
95
FGIN
I (S)
FG signal input terminal Not used (fixed at “L”)
96
TEST1
I
97
TEST2
I
Input terminal for the test (fixed at “L”)
98
TEST3
I
99
DVSS
—
Ground terminal (digital system)
100
EFMO
O
EFM signal output to the overwrite head driver (IC181) when recording mode
* I (S) stands for schmitt input, I (A) for analog input, O (3) for 3-state output, and O (A) for analog output in the column I/O.
74
Pin No.
Pin Name
I/O
Description
1
WMOUT
O
Serial data output to the equipment connected to other unit Not used (open)
2
WMCLK
I
Serial data transfer clock signal input from the equipment connected to other unit
Not used (fixed at “L”)
Not used (fixed at “L”)
3
LEVEL-L
O
Left channel level output to the master controller (IC501)
4
LEVEL-R
O
Right channel level output to the master controller (IC501)
5
LEDDATA
O
Serial data output terminal for the LED driver Not used (open)
6
—
O
Not used (open)
7
LEDCLK
O
Serial data transfer clock signal output terminal for the LED driver Not used (open)
8
BYTE
I
External data bus line byte selection signal input “L”: 16 bit, “H”: 8 bit (fixed at “L”)
9
CNVSS
—
Ground terminal
10
XIN-T
I
Sub system clock input terminal (32.768 kHz) Not used (fixed at “L”)
11
XOUT-T
O
Sub system clock output terminal (32.768 kHz) Not used (open)
12
S.RST
I
System reset signal input from the reset signal generator (IC931) “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
13
XOUT
O
Main system clock output terminal (10 MHz)
14
GND
—
Ground terminal
15
XIN
I
Main system clock input terminal (10 MHz)
16
3.3V
—
Power supply terminal (+3.3V)
17
NMI
I
Non-maskable interrupt input terminal (fixed at “H” in this set)
18
P.DOWN
I
Power down detection signal input terminal “L”: power down, normally: “H”
19
WMSYNC
I
Sync signal input from the equipment connected to other unit Not used (fixed at “L”)
20
I2CBUSY
O
Busy signal output for the I2C bus “L” active Not used (pull up)
21
L3CLK
O
L3 bus data transfer clock signal output to the A/D, D/A converter (IC201)
22
L3DATA
O
L3 bus data output to the A/D, D/A converter (IC201)
23
—
O
Not used (open)
24
ELEUP
O
Mini-disc elevator up/down motor control signal output terminal
“H” active Not used (open)
“H” active Not used (open)
25
—
O
Not used (open)
26
ELEDOWN
O
Mini-disc elevator up/down motor control signal output terminal
“H” active Not used (open)
“H” active Not used (open)
27
SQSY
I
Subcode Q sync (SCOR) input from the CXD2654R (IC121)
“L” is input every 13.3 msec Almost all, “H” is input
“L” is input every 13.3 msec Almost all, “H” is input
28
RESET SW
I
Reset switch input terminal “L”: reset Not used (fixed at “L”)
29
I2CCLK
I/O
Shift clock signal input/output terminal for the I2C bus
30
I2CDATA
I/O
Serial data input/output terminal for the I2C bus
31
FLDATA
O
Display serial data output terminal Not used (open)
32
—
O
Not used (open)
33
FLCLK
O
Display serial data transfer clock signal output terminal Not used (open)
34
FLCS
O
Display serial chip select signal output terminal “L” active Not used (open)
35
SWDT
O
Writing data output to the CXD2654R (IC121)
36
SRDT
I
Reading data input from the CXD2654R (IC121)
37
SCLK
O
Serial clock signal output to the CXD2654R (IC121)
38
OPTSEL0
O
Selection signal output for the optical input signal Not used (open)
39
SENSOR
I
Elevator position detect sensor input terminal Not used (fixed at “L”)
40
SENSOR2
I
Elevator position detect sensor input terminal Not used (fixed at “L”)
41
HEADDOWN
O
Over write head up/down motor control signal output terminal
“H” active Not used (open)
“H” active Not used (open)
• MD DIGITAL BOARD IC316 M30624MG-A16FP (MD MECHANISM CONTROLLER)
75
Pin No.
Pin Name
I/O
Description
42
HEADUP
O
Over write head up/down motor control signal output terminal
“H” active Not used (open)
“H” active Not used (open)
43
JOG0
I
Jog dial pulse input terminal (A phase input) Not used (open)
44
JOG1
I
Jog dial pulse input terminal (B phase input) Not used (open)
45
WMINV
O
Clock signal phase inversion control signal output to the equipment connected to other unit
Not used (open)
Not used (open)
46
LEDLAT
O
Serial data latch pulse output to the LED driver “L” active Not used (pull down)
47
OPTSEL1
O
Selection signal output terminal for digital signal Not used (open)
48
DARST
O
Reset signal output terminal “L”: reset Not used (open)
49
MUTE
O
Audio line muting control signal output terminal “L”: line muting on
Not used (open)
Not used (open)
50
STB
O
Power control strobe signal output for the external device
“L”: standby mode, “H”: power on Not used (open)
“L”: standby mode, “H”: power on Not used (open)
51
CHACK-IN
I
Detection input from the disc loading in detect switch (S573)
“L”: disc chucking, others: “H” Not used
“L”: disc chucking, others: “H” Not used
52
HOME
I
Detection input from the elevator home position detect switch
“L”: home position, others: “H” Not used (fixed at “L”)
“L”: home position, others: “H” Not used (fixed at “L”)
53
PACK-OUT
I
Detection input from the disc loading out detect switch (S602)
“L”: loading out position, others: “H”
“L”: loading out position, others: “H”
54
LDIN
O
Mini-disc loading motor control signal output to the motor driver (IC153)
“H” active *1
“H” active *1
55
LDOUT
O
Mini-disc loading motor control signal output to the motor driver (IC153)
“H” active *1
“H” active *1
56
LD-LOW
I
The loading motor drive voltage control signal output to the motor driver (IC153)
“H” active Not used (open)
“H” active Not used (open)
57
LDON
O
Laser diode on/off control signal output to the automatic power control circuit “H”: laser on
58
REFLECT
I
Detection input from the disc reflection rate detect switch (S102-1)
“L”: high reflection rate disc, “H”: low reflection rate disc
“L”: high reflection rate disc, “H”: low reflection rate disc
59
PROTECT
I
Rec-proof claw detect input from the protect detect switch (S102-2) “H”: write protect
60
PB-P
I
Detection input from the playback position detect switch (S604) “L” active
61
REC/PB
O
Not used (open)
62
3.3V
—
Power supply terminal (+3.3V)
63
LIMIT-IN
I
Detection input from the sled limit-in detect switch (S101)
The optical pick-up is inner position when “L”
The optical pick-up is inner position when “L”
64
GND
—
Ground terminal
Laser modulation select signal output to the HF module switch circuit
Playback power: “H”, Stop: “L”,
Recording power:
65
MOD
O
2 sec
0.5 sec
*1 Mini-disc loading motor (M903) control
Loading
Eject
Stop
Brake
LDIN (pin tf)
“H”
“L”
“L”
“H”
LDOUT (pin tg)
“L”
“H”
“L”
“H”
Terminal
Mode
76
Pin No.
Pin Name
I/O
Description
66
XLATCH
O
Serial data latch pulse signal output to the CXD2654R (IC121)
67
WRPWR
O
Laser power select signal output to the CXD2654R (IC121) and HF module switch circuit
“L”: playback mode, “H”: recording mode
“L”: playback mode, “H”: recording mode
68
LOADING
SEL: L
I
Setting terminal for the loading control method
“H”: not used IN switch (fixed at “L”)
“H”: not used IN switch (fixed at “L”)
69
L3MODE
O
L3 bus mode control signal output to the A/D, D/A converter (IC201)
70, 71
—
I
Not used (fixed at “H”)
72
SCTX
O
Recording data output enable signal output to the CXD2654R (IC121) and over write head driver
(IC181) Writing data transmission timing output (Also serves as the magnetic head on/off
output)
(IC181) Writing data transmission timing output (Also serves as the magnetic head on/off
output)
73
XINT
I
Interrupt status input from the CXD2654R (IC121)
74
REC-P
O
Detection input from the recording position detect switch (S601) “L”: recording position
75
DQSY
I
Digital In U-bit CD format subcode Q sync (SCOR) input from the CXD2654R (IC121)
“L” is input every 13.3 msec Almost all, “H” is input
“L” is input every 13.3 msec Almost all, “H” is input
76
—
I
Not used (open)
77
DIGRST
O
Reset signal output to the CXD2654R (IC121) and BH6511FS (IC152) “L”: reset
78
SENS
I
Internal status (SENSE) input from the CXD2654R (IC121)
79
MNT3
I
Spindle servo lock status monitor signal input from the CXD2654R (IC121)
80
MNT2
I
Busy signal input from the CXD2654R (IC121)
81
MNT1
I
Track jump detection signal input from the CXD2654R (IC121)
82
MNT0
I
Focus OK signal input from the CXD2654R (IC121)
“H” is input when focus is on (“L”: NG)
“H” is input when focus is on (“L”: NG)
83
SENSOR SW
O
Control signal output for the sensor gain selection Not used (fixed at “L”)
84
DISK5
I
Detection input from the disc detect switch “L”: disc is set Not used (fixed at “L”)
85
DISK1
I
Detection input from the disc detect switch “L”: disc is set Not used (fixed at “L”)
86
DISK2
I
Detection input from the disc detect switch “L”: disc is set Not used (fixed at “L”)
87
SCL
O
Serial clock signal output to the EEPROM (IC171)
88
SDA
I/O
Two-way data bus with the EEPROM (IC171)
89
DISK4
I
Detection input from the disc detect switch “L”: disc is set Not used (fixed at “L”)
90
DISK3
I
Detection input from the disc detect switch “L”: disc is set Not used (fixed at “L”)
91
HEADSW-
DOWN
I
Detection input from the over write head down position detect switch
“L”: down position Not used (fixed at “L”)
“L”: down position Not used (fixed at “L”)
92
HEADSW-UP
I
Detection input from the over write head up position detect switch
“L”: up position Not used (fixed at “L”)
“L”: up position Not used (fixed at “L”)
93 to 95
KEY3 to KEY1
I
Key input terminal (A/D input) Not used (fixed at “H”)
96
AVSS
—
Ground terminal (for A/D converter)
97
KEY0
I
Key input terminal (A/D input) Not used (fixed at “H”)
98
VREF
I
Reference voltage (+3.3V) input terminal (for A/D converter)
99
+3.3V
—
Power supply terminal (+3.3V)
100
WMIN
I
Serial data input from the equipment connected to other unit Not used (fixed at “L”)
Click on the first or last page to see other CMT-F3MD / HCD-F3MD service manuals if exist.