DOWNLOAD Sony CMT-CPZ3 / HCD-CPZ3 Service Manual ↓ Size: 5.29 MB | Pages: 75 in PDF or view online for FREE

Model
CMT-CPZ3 HCD-CPZ3
Pages
75
Size
5.29 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cmt-cpz3-hcd-cpz3.pdf
Date

Sony CMT-CPZ3 / HCD-CPZ3 Service Manual ▷ View online

HCD-CPZ3
13
2-16.  CLOSE  LEVER
2-17.  LEVER (DIR),  GEAR (IDL-B)
1  washer (3-1-0.4)
2  SPR-E lever close
4  shaft disc stop
5  close lever 
3 claw
– Bottom view –
3  pulley (gear)
2  capstan retaining ring
9  lever (DIR) 
5  gear (IDL-A)
q;  gear (IDL-B)
1  tension coil spring (DIR)
8 stopper
6  Loosen the screw. 
7  Hold the Release lever
     and change the direction.
4  gear (cap)
– Bottom view –
HCD-CPZ3
14
2-18.  GEAR (IDL-C)
6 claw
1  gear (IDL-F)
5  lever (gear loading)
2  two claws
4  three hooks
3  gear (IDL-D)
7  gear (IDL-C)
HCD-CPZ3
15
SECTION  3
TEST  MODE
COMMON  TEST  MODE
This mode is used to check operations of Ampli
fi er.
Procedure:
1.  Press the [
?
/
1
] key to turn the power ON.
2.  Press three keys of [DSGX] and [
x
] (CD) and [PUSH EN-
TER] JOG simultaneously.
3.   When the COMMON test mode is activated, “
s” blinks on 
the liquid crystal display.
4.   Turn the [BASS] knob counterclockwise, “TONE MIN” is dis-
played on the liquid crystal display. Turn the [BASS] knob clock-
wise, “TONE MAX” is displayed on the liquid crystal display.
Turn the [TREBLE] knob clockwise or counterclockwise,
“TONE FLAT” is displayed on the liquid crystal display.
Turn the [VOLUME] knob counterclockwise, “VOL MIN” is
displayed on the liquid crystal display. Turn the [VOLUME]
knob clockwise, “VOL MAX” is displayed on the liquid crys-
tal display.
5.   To release this mode, press the [
?
/
1
] key.
PANEL  TEST  MODE
This mode is used to check the liquid crystal display, LED, model, 
destination, software version and key.
Procedure:
1.   Press the [
?
/
1
] key to turn the power ON.
2.  Press three keys of [DSGX], [DISPLAY] and [
x
] (CD) simul-
taneously.
3.   Liquid crystal display and LEDs are all turned on.
4.  When you want to enter the model, destination and version 
display mode, press the [PLAY MODE/DIRECTION/TUNING 
MODE] key. 
 
The model and destination are displayed alternately on the liq-
uid crystal display.
5.  Each time [PLAY MODE/DIRECTION/TUNING MODE] 
key is pressed, the display changes starting from MC ver-
sion, GC version, CD version, CDD version, CDMA version, 
CDMB version, BDA version, BDB version, ST version, TA 
version, TM version, and TC version this order, and returns to 
the MC version display on the liquid crystal display.
6.   When [FUNCTION] key is pressed while the version numbers 
are being displayed except model and destination, year, month 
and day of the software creation display. When [FUNCTION] 
key is pressed again, the display returns to the software ver-
sion display. When [PLAY MODE/DIRECTION/TUNING 
MODE] key is pressed while year, month and day of the soft-
ware creation are being displayed, the year, month and day of 
creation of the software versions are displayed on the liquid 
crystal display in the same order of version display.
7.   Press the [REPEAT/FM MODE] key, the key check mode is 
activated.
8.  In the key check mode, the liquid crystal display displays 
“K0 J0 V0”.
 
Each time a key is pressed, “K” value increases. Howev-
er, once a key is pressed, it is no longer taken into account.
“V” value increases in the manner of 0, 1, 3, 5 ... if [VOL-
UME] knob is turned clockwise, or it decreases in the manner 
of 0, 9, 7, 5 ... if [VOLUME] knob is turned counterclockwise.
“J” value increases in the manner of 0, 1, 2, 3 ... if [BASS], 
[TREBLE] and [PUSH ENTER] knob are turned clockwise, or 
it decreases in the manner of 0, 9, 8, 7 ... if [BASS], [TREBLE] 
and [PUSH ENTER] knob are turned counterclockwise.
9.   To release this mode, press three keys in the same manner as 
step 2, or disconnect the power cord.
COLD  RESET
The cold reset clears all data including preset data stored in the 
RAM to initial conditions. Execute this mode when returning the 
set to the customer.
Procedure:
1.   Press the [
?
/
1
] key to turn the power ON.
2.   Press three keys of [
?
/
1
], [DISPLAY] and [
x
] (TAPE) simul-
taneously.
3.   The liquid crystal display becomes blank instantaneously, and 
the set is reset.
SHIP  MODE (NO  MEMORY  CLEAR)
This mode moves the optical pick-up to the position durable to 
vibration. Use this mode when returning the set to the customer 
after repair.
Procedure:
1.  Press the [
?
/
1
] key to turn the power ON.
2.   Press the [FUNCTION] key to select “CD”.
3.   Press three keys of [DSGX], [
x
] (CD) and [  +] simultane-
ously and the ship mode is set.
4.   After the “STANDBY” display blinks, “LOCK” is displayed 
on the liquid crystal display, and the ship mode is set.
SHIP  MODE (MEMORY  CLEAR)
This mode moves the optical pick-up to the position durable to 
vibration. Use this mode when returning the set to the customer 
after repair.
Procedure:
1.   Press the [
?
/
1
] key to turn the power ON.
2.   Press the [FUNCTION] key to select “CD”.
3.   Press three keys of [DSGX],  [
x
] (CD) and [  –] simultane-
ously.
4.   After the “STANDBY” display blinks, “LOCK” is displayed 
on the liquid crystal display, and the ship mode is set.
CD  SLOT  LOCK  MODE
This mode is used to unable to take sample disc out of disc slot in 
the shop.
Procedure:
1.  Press the [
?
/
1
] key to turn the power ON.
2.  Press the [FUNCTION] key to select “CD”.
3.  Insert a CD disc.
4.  While pressing the [
Z
] (CD) key, press the [
x
] (CD) key for 5  
seconds.
5.  The message “LOCKED” is displayed on the liquid crystal 
display and the disc slot is locked (Even if pressing the [
Z
(CD) key, the message “LOCKED” is displayed on the liquid 
crystal display and the disc slot is locked).
6.  To release from this mode, pressing the [
Z
] (CD) key, press the 
[
x
] (CD) key for 5 seconds.
7.  The message “UNLOCKED” is displayed on the liquid crystal 
display and the disc slot is unlocked.
CD  SERVICE  MODE
This mode can run the CD sled motor freely. Use this mode, for 
instance, when cleaning the optical pick-up.
Procedure:
1.   Press the [
?
/
1
] key to turn the power ON.
2.   Press the [FUNCTION] key to select “CD”.
3.  Press three keys of [PLAY MODE/DIRECTION/TUNING 
MODE], [
M L] and [
x
] (CD) simultaneously.
4.   Press the [
M L] key to move the optical pick-up to out-
side track and the message “SLED OUT” is displayed on the 
liquid crystal display, or press the [
l m] key to inside 
track and the message “SLED IN” is displayed on the liquid 
crystal display.
5.   Press the [CD 
u] key, “LD OFF” is displayed and laser di-
ode is turned off. Each time [CD 
u] key is pressed, laser 
diode ON/OFF switch is performed.
6.   To release this mode, press the [
?
/
1
] key.
HCD-CPZ3
16
CD  ERROR  CODE  MODE
This mode can be used for error display of CD section.
Procedure:
1.   Press the [
?
/
1
] key to turn the power ON.
2.   Press the [FUNCTION] key to select “CD”.
3.  Press three keys of [PLAY MODE/DIRECTION/TUNING 
MODE], [  +] and [
x
] (CD) simultaneously.
Note:  Error code is not displayed on the liquid crystal display.
CD  SERVO  TEST  MODE
This mode used to check operation of optical pick-up.
Procedure:
1.   Press the [
?
/
1
] key to turn the power ON.
2.   Press the [FUNCTION] key to select “CD”.
3. Press three keys of [PLAY MODE/DIRECTION/TUNING 
MODE], [l m] and [
x
] (CD) simultaneously.
4. When the CD servo test mode is activated, optical pick-up 
moves.
CD  POWER  MANAGE
This mode is for switch the CD power supply on/off. Even if this 
state pulls out AC plug, it is held.
Procedure:
1.  Press the  [
?
/
1
] key to turn the power on.
2.  Press the [FUNCTION] key to select “CD”.
3.  Press the  [
?
/
1
] key again to turn the power off (standby).
4.  While pressing the [
x
] (CD) key, press the [
?
/
1
] key.
5.  It turns power on and display “CD POWER”, then display 
“ON” or “OFF”.
SECTION  4
MECHANICAL  ADJUSTMENTS
Precaution
1.  Clean the following parts with a denatured alcohol-moistened 
swab: 
     
record/playback heads  pinch rollers
     
erase head 
rubber belts
     capstan 
idlers
2.   Demagnetize the record/playback head with a head demagne-
tizer.
3.   Do not use a magnetized screwdriver for the adjustments.
4.   After the adjustments, apply suitable locking compound to the 
parts adjusted.
5.  The adjustments should be performed with the rated power 
supply voltage unless otherwise noted.
Torque Measurement
Note: Refer to “SUPPLEMENT-1” for New/Former.
Mode
Torque 
meter
Meter reading 
(Former)
Meter reading 
(New)
FWD
CQ-102C
3.06 N • m – 6.96 N • m
31 – 71 g • cm
(0.43 – 0.98 oz • inch)
2.9 – 7.4 mNm
(30 – 75 g • cm)
FWD 
back 
tension
CQ-102C
0.19 N • m – 0.58 N • m
2 – 6 g • cm
(0.02 – 0.08 oz • inch))
0.14 – 0.59 mNm
(1.5 – 6 g • cm)
REV
CQ-102RC
3.06 N • m – 6.96 N • m
31 – 71 g • cm
(0.43 – 0.98 oz • inch))
2.9 – 7.4 mNm
(30 – 75 g • cm)
REV 
back 
tension
CQ-102RC
0.19 N • m – 0.58 N • m
2 – 6 g • cm
(0.02 – 0.08 oz • inch)
0.14 – 0.59 mNm
(1.5 – 6 g • cm)
FF/REW
CQ-201B
6.96 N • m – 14.02 N • m
71 – 143 g • cm
(0.98 – 1.99 oz • inch)
5.4 – 16.7 mNm
(55 – 170 g • cm)
FWD 
tension
CQ-403A
9.80 N • m
100 g or more
(3.53 oz or more)
0.88 Nm
(90 g more)
REV 
tension
CQ-403R
9.80 N • m
100 g or more
(3.53 oz or more)
0.88 Nm
(90 g more)
Ver. 1.1
Page of 75
Display