13
CFD-S40CP
4-1. MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power sup-
ply voltage (9V) unless otherwise noted.
Torque Measurement
Torque
Torque Meter
Meter Reading
1.77 – 5.88 mN•m
Forward
CQ-102C
(18 – 60 g•cm)
(0.25 – 0.83 oz•inch)
Forward
0.1 – 0.49 mN•m
Back Tension
CQ-102C
(1.0 – 5.0 g•cm)
(0.014 – 0.069 oz•inch)
4.42 – 9.31 mN•m
Fast Forward
CQ-201B
(45 – 95 g•cm)
(0.62 – 1.32 oz•inch)
4.42 – 9.31 mN•m
Rewind
CQ-201B
(45 – 95 g•cm)
(0.62 – 1.32 oz•inch)
Tape Tension  Measurement
Torque Meter
Meter Reading
CQ-403A
more than 60g
(more than 2.12 oz)
SECTION 4
ADJUSTMENTS
4-2. ELECTRICAL ADJUSTMENTS
 TAPE RECORDER SECTION
Standard Output Level
Output terminal
HP OUT
load impedance
32 
output signal level
0.25V (–10dB)
Test Tape
Type
Signal
Used for
WS-48A
3kHz, 0dB
Tape Speed Adjustment
Tape Speed Adjustment
Procedure :
Mode : Playback
Adjustment Value : 3,000Hz
Standard Value : 2,940 - 3,060Hz
Frequency difference between the beginning and the end of the tape
should be within 1.5% (45Hz).
set
test tape
WS-48A
(3kHz, 0dB)
32
digital frequency
counter
J301 (phones)
Tape speed adjustment 
control inside motor
 0dB = 0.775V
Adjustment Location : Mechanism deck
14
CFD-S40CP
MW/LW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455kHz
(     ): AEP, UK
AM (MW) FREQUENCY COVERAGE CHECK
Frequency Display
530 kHz
1,710 kHz
(531 kHz)
(1,611 kHz)
Reading on Digital voltmeter
1.0 (0.8)
+ 0.7 V
4.8 (5.0)
+ 1.2 V
– 0.5 V
– 0.6 V
Adjustment Part
<confirmation>
<confirmation>
(     ): AEP, UK
AM (MW) TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L4 (L3)
CT3
620 kHz (621 kHz)
1,400 kHz (1,404 kHz)
LW FREQUENCY COVERAGE ADJUSTMENT (AEP, UK)
Frequency Display
153 kHz
279 kHz
Reading on Digital voltmeter
0.7
+ 0.3 V
5.0 
± 0.1 V
– 0.4 V
Adjustment Part
<confirmation>
L4
LW TRACKING ADJUSTMENT (AEP, UK)
Adjust for a maximum reading on level meter.
L3
CT5
162 kHz
261 kHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.6 
± 0.4 V
4.0 
± 0.3 V
Adjustment Part
<confirmation>
L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
Adjustment Location : Main board (See page 15)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
 TUNER  SECTION
 AM Section
Function switch : AM (US, Canadian, Korean, Taiwan)
  MW or LW (AEP, UK)
Volume
: MIN
 FM Section
Function switch : FM
Volume
: MIN
• Connecting Level Meter (FM and AM)
• Connecting Digital Voltmeter (FM and AM)
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
22.5kHz frequency deviation by 
1kHz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01
µF
 0dB = 1 
µV
i
 jack
set
32 
level meter
(range: 0.5–5 V ac)
digital
voltmeter
100 k
TP (VT)
(JW17)
Ver 1.1  12001.07
15
CFD-S40CP
CONTROL BOARD (Condustor side)
R616
S604
R606
R611
TEST B
TEST A
VOLUME
MEGA BASS
SOUND
R636
R631
R603
R632
R633
R605
R604
S603
-
S606
S605
S611
+
TEST mode : momentanly short
Focus Bias Check
1. Connect the oscilloscope between TP4003 (RF DC) and GND
on CD board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01) (CD)
3. Press the u button two times (LPC ON).
4. Confirm that the oscilloscope waveform is as shown in the fig-
ure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the cen-
ter of the waveform can be clearly distinguished.
5. Press the u button.(LPC OFF)
6. Perform confirmation in step 4 again.
7. Insert the disc (TCD-W082L)(Part No:J-2502-063-2)(CD-RW)
8. Perform confirmation in step 3 to step 6.
RF Signal Reference Waveform (eye pattern)
RF level
(CD)
0.8 – 1.2 Vp-p (LPC ON)
0.9 – 1.5 Vp-p (LPC OFF)
(CD-RW)
1.0 – 1.4 Vp-p (LPC ON)
0.7 – 1.3 Vp-p (LPC OFF)
VOLT/DIV : 200mV
TIME/DIV : 500 nS
CD SECTION
Perform all CD section check and all adjustments in the test mode.
How to put the set into CD test mode
1. Press the POWER button turn the set ON.
2. Press the FUNCTION button to select CD.
3. Set Tset mode by momentarily shorting both side of TEST A.
4. Press the x button two times. The set is into CD test mode
(
88 is displayed)
5. Turn the power off to release test mode.
 
 
 
 
 
 
2
8
C1092
Q1010
C
C1084
RV1002
R1071
R1078
R1076
R1072
R1079
R107
R1067
R1070
4
Q1007
R1019
IC1007
R1004
oscilloscope
(AC range)
TP 4002(FE)
IC 1007 10pin
CD BOARD   (SIDE A)
When observing the eye pattern, set the oscilloscope for AC range
and raise certical sensitivity
 
 
 
 
 
 
2
4
2
C1065
R1037
R1033
C1049
TP4002(FE)
R1060
R1059
R1061
R1047
C1056
C1058
TP4003(RF DC)
C1068
IC1006
L1007
R1038
R1048
C1050
FB1
FB
FB
FL100
TP4003
(RF DC)
CD BOARD
  
(SIDE A)
oscilloscope
(AC range)
(GND)
Focus Erorr Adjustment
1. Connect the oscilloscope between TP4002(FE) and IC1007 10
pin on CD board.
2. Set to no disc and CD stop status.
3. Adjust RV1001 so that the center of the waveform meets the
specifications.
A
A: –100mV to +100mV
0V
Center of the waveform.
Specifications :
Adjustment Location : See page 16
16
CFD-S40CP
T1: MW/LW
    IF Adjustment
L3: LW Tracking
     Adjustment
     (AEP, UK)
L3: MW Tracking
     Adjustment
     (AEP, UK)
CT5: LW Tracking
        Adjustment
        (AEP, UK)
CT3: AM (MW) Tracking
        Adjustment
L4: AM Tracking Adjustment (US, CND, Korean, Taiwan)
L4: LW Frequency Coverage Adjustment (AEP, UK)
L2: FM Frequency 
Coverage Adjustment
L1
CT1
FM Tracking Adjustment
TUNER BOARD   
(Component side)
Adjustment Location :
CD BOARD   
(SIDE A)
IC1007
RV1001:Focus Erorr Adjustment
IC1006
Ver 1.1  12001.07