– 9 –
 CD SECTION
Note on Adjustment
1. Perform adjustment in test mode.
After adjustment, be sure to release test mode.
2. Perform adjustments in the order given.
3. Use the disc (YEDS-18. Part No. 3-702-101-01) only when  so
indicated.
Before adjustment
Put the set into test mode and perform the following checks.
Repair if there are any problems.
• Sled Motor Check
1. Press 
fl button, then press OFF button.
2. Press 
±, ≠buttons and confirm that the Optical pick-up
moves smoothly from the innermost to outermost circumference
and back smoothly and with no catching or abnormal noises.
(Cancellation of BTL mute)
± : Optical pick-up moves to the outer circumference
≠ : Optical pick-up moves to the inner circumference
• Focus Search Check
1. Press 
fl button. (Focus search operation is performed continu-
ously.)
2. Look at the Optical pick-up objective lens and confirm that it
moves up and down smoothly, with no catching or abnormal
noises.
3. Press 
π button.
Confirm that focus search operation stops. If it does not , press
π button again longer.
Note :
 When the malfunction is occurred by mis-passing
other buttons, turn off the power and check again
from making the test mode.
How to put the Set into Test Mode
1. Make sure the POWER switch (S801) is off and then turn on the
power. (The LCD801 all light up.)
2. Set Test Mode by momentarily shorting both of the test mode
terminals with a jumper. (Shorting the terminals momentarily is
sufficient).
[SW BOARD]
How to Release Test Mode
1. Press the FUNCTION switch (S809).
2. Turn the POWER OFF.
E-F Balance Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Adjustment Procedure :
1. Connect the oscilloscope to test point TP (VC) and TP (TO) on
MAIN board.
2. Put the set into test mode.
3. optical pick-up setting  to the center by 
± or ≠ button
pushing.
4. Insert disc (YEDS-18) and press 
fl button.
5. Adjust RV703 so that the oscilloscope traveres waveform is sym-
metrical, as shown in the figure below.
6. Release test mode after adjustment is completed.
[MAIN BOARD]
Adjustment Location : Main board (See page 12)
A          
0V
B
C
VOLT / DIV : 1V
TIME / DIV :1ms
A = B
C = 180 – 420mV
TEST mode
Open : Normal mode
Short : Test mode
Jamper wire
TP (TO)
oscilloscope
(DC range)
TP (VC)
– 10 –
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up block is
replaced.
Adjustment procedure :
1. Connect the oscilloscope to test point TP (VC) and TP (RFO) on
MAIN board.
2. Put the set into test mode.
3. Optical pick-up setting to the center by 
± or ≠ button
pushing.
4. Insert disc (YEDS-18) and press 
fl button.
5. Press the 
fl button.  (Tracking servo ON)
6. Adjust RV701 so that the oscilloscope waveform is as shown in
the figure below (eye pattern).
A good eye pattern means that the diamond shape (
) in the cen-
ter of the waveform can be clearly distinguished.
7. Release test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
[MAIN BOARD]
Focus/Tracking Gain Adjustment
A frequency responce analyzer is necessary in order to perform this
adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, mechanical shock and skipping occurs
more easily.
• When gain adjustment is off, the symptoms below appear.
The following is a simple adjustment method.
– Primary Adjustment –
Note :
Since exact adjustment cannot be performed, remember
the positions of the controls before performing the
adjustment.If the positions after the primary adjustment
are only a little different, return the controls to the origi-
nal position.
Procedure :
1. Keep the set horizontal.
If the set is not horizontal, this adjustment cannot be performed
due to the gravity against the 2-axis device.
2. Insert disc (YEDS-18) and press 
fl button.
3. Connect oscilloscope to TP (FO) and TP (VC) on MAIN board.
4. Adjustment RV702 on MAIN board so that the waveform is as
shown in the figure below. (Focus gain adjustment)
1.0 – 1.4 V 
VOLT/DIV : 0.2 V
TIME/DIV: 500 ns  
r
The time until music starts becomes
 longer for STOP 
→ 
fl
 
button or 
automatic selection.
≠, ± buttons pressed.)
(Normally takes about 2 seconds.)
r
Music does not start and disc
continues to rotate for STOP 
fl
 
button or automatic selection.
≠, ± buttons pressed.)
Sound is interrupted during PLAY. 
Or time counter display stops
progressing.
r
More noise during 2-axis device
operation.
Symptoms
Gain
Focus
Tracking
low   
  low or high
           low
           low
high
            high
TP (RFO)
oscilloscope
(DC range)
TP (VC)
Adjustment Location : Main board (See page 12)
– 11 –
5. Connect oscilloscope to TP (TO) and TP (VC) on MAIN board.
6. Adjust RV704 on MAIN board so that the waveform is as shown
in the figure below. (Tracking gain adjustment)
VOLT/DIV : 1V
TIME/DIV : 2ms
• Incorrect Examples (fundamental waveform appears)
low tracking gain
VOLT/DIV : 1V
TIME/DIV : 2ms
high tracking gain
High fundamental wave
than for low gain
VOLT/DIV : 1V
TIME/DIV : 2ms
VOLT/DIV : 100mV
TIME/DIV : 2ms
• Incorrect Examples (DC level changes more than on adjusted
waveform)
VOLT/DIV : 100mV
low focus gain
TIME/DIV : 2ms
VOLT/DIV : 100mV
high focus gain
TIME/DIV : 2ms
[MAIN BOARD]
75mV
0V
200mV
0V
0V
0V
0V
(                                  )
100mV
0V
TP (TO)
TP (FO)
oscilloscope
(DC range)
TP (VC)
– 12 –
Adjustment Location :
L4 : AM Frequency Coverage Adjustment
L2 : FM Frequency Coverage Adjustment
L1 : FM Tracking Adjustment
L3 : AM Tracking Adjustment
CT2 : AM Tracking Adjustment
CFT1 : AM  IF Adjustment
T1 : FM  IF Adjustment
CT1 : FM Tracking Adjustment
[TUNER BOARD]
(Component side)
RV702 : Focus Gain Adjustment
[MAIN BOARD]
(Component side)
RV703 : E-F Balance Adjustment
RV704 : Tracking Gain Adjustment
RV701 : Focus Bias Adjustment
Page of 37
Display