– 5 –
SECTION 3
DISASSEMBLY
Note :
 Follow the disassembly procedure in the numerical order given.
r
 The equipment can be removed using the following procedure.
3-1. CABINET (FRONT), CABINET (REAR), SW BOARD
3-2. BATT BOARD, TUNER BOARD, AC INLET BOARD,  POWER BOARD
5
 Screws +BVTP (2.6X8)
Cabinet (Front)
SW board
4
1
2
3
 Screws +BVTP (3X14)
3
 Screws
    +BVTP (3X14)
Cabinet (Rear)
6
BATT board
Power board
AC inlet board
1
2
8
7
 Screws 
    +BVTP (3X10)
5
 Screw +BVTP (3X10)
Cabinet (Rear)
Tuner board
6
3
Tuner retainer board
4
 Screw
    +BVTP (3X10)
Cabinet (Upper)
Optical pick-up section
Mechanism deck
SW board
Main board, CD motor board
REC SW board
BATT board, Tuner board, AC inlet board, Power board
Cabinet (Front)
Cabinet (Rear) 
Set
– 6 –
3-3. CABINET (UPPER)
3-4. OPTICAL PICK-UP SECTION, MECHANISM DECK, MAIN BOARD,
       REC SW BOARD, CD MOTOR BOARD
Cabinet (Rear)
6
7
3
5
2
 STOP/EJECT
4
 Screws 
    +BVTP (3X10)
1
 Screws 
    +BVTP (3X10)
Handle
Tape operation buttons
Cabinet (Upper)
2
 CNP707 (6pin)
Cabinet (Rear)
Main board
REC SW board
3
 Wire (Flat type) (16 core) 
     to MAIN board (CN701)
5
 Screws +BVTP (3X10)
7
 Screws +BVTP (3X10)
6
1
4
Optical pick-up
section
Mechanism deck
9
CD motor board
8
 Remove solder
– 7 –
4-2. ELECTRICAL ADJUSTMENTS
 TAPE RECORDER SECTION
Standard Output Level
Output terminal
HP OUT
load impedance
32
output signal level
0.25V (–10dB)
Test Tape
Type
Signal
Used for
WS-48A
3kHz, 0dB
Tape Speed Adjustment
 0dB = 0.775V
Tape Speed Adjustment
Procedure :
Mode : Playback
1. Adjust the screw (Tape Speed Adjustment control inside  motor)
for 2,970 – 3,030 Hz reading on the digital frequency counter.
2. Frequency difference between the beginning and the end of the
tape should be within 1.5% (45Hz).
Adjustment Location :
SECTION 4
ADJUSTMENTS
4-1. MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Torque
Torque Meter
Meter Reading
Forward
CQ-102C
30 – 70 g•cm
(0.42 – 0.97 oz•inch)
Forward
CQ-102C
1.5 – 5.5 g•cm
Back Tension
(0.020 – 0.076 oz•inch)
Fast Forward
CQ-201B
more than 60 g•cm
(more than 0.84 oz•inch)
Rewind
CQ-201B
more than 60 g•cm
(more than 0.84 oz•inch)
 Tape Tension  Measurement
Torque Meter
Meter Reading
CQ-403A
more than 100g
(more than 3.53 oz)
set
test tape
WS-48A
(3kHz, 0dB)
32
digital frequency
counter
J301 (phones)
Tape speed adjustment 
control inside motor
– 8 –
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
CFT1
450kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter
Confirmation
531kHz
0.8 – 1.2 V
L4
1,611kHz
4.9 – 5.3 V
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
621kHz
CT2
1,404kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
10.7MHz
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter
Confirmation
87.5MHz
1.1 – 1.5 V
L2
108MHz
3.3 – 3.7 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.5MHz
CT1
108MHz
Adjustment Location : Tuner board (See page 12)
 TUNER  SECTION
 AM Section
Function switch : AM
Volume
: MIN
 FM Section
Function switch : FM
Volume
: MIN
Frequency Coverage Adjustment
Setting :
[TUNER BOARD]
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
22.5kHz frequency deviation by 400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01
µ
F
set
32
J301 (phones)
level meter
 0dB = 1 
µ
V
Digital voltmeter
Adjustment Location : Tuner board (See page 12)
Page of 37
Display

Click on the first or last page to see other CFD-S27 (serv.man2) service manuals if exist.