– 13 –
7. Move the holder (sensor) center so that the flat portion center at the top of the SENS (CH1) input waveform and the ‘’H” center of
TEST (CH2) coincide.
8. Tighten the fixed screw to fix the disc table, then press the 
[CLEAR]
 button.
9. The disc table rotates in the counterclockwise direction.  Measure the waveform and make sure that the flat portion center at the top of
the SENS (CH1) input waveform and the ‘’H” center of TEST (CH2) coincide.
10. If the adjustment is not successful, press the 
[CLEAR]
 button to rotate the disc table in the clockwise direction,
and perform steps 6 to 9.
Note:
During the adjustment mode, the rotational direction is switched each time the 
[CLEAR]
 button is pressed.
Pressing the 
[CHECK]
 button enters the loading mode which will be described later. Pressing the 
[CLEAR]
 button rotates the disc table again.
TEST (CH2) waveform
SENS (CH1) waveform
Flat portion center of
SENS (CH1) waveform
Holder (sensor)
Fixed screw
– 14 –
MAGNET  ASSY  ALIGMENT
1. Check that there is no disc in the unit and then turn ON the power.  Open the door, and set a disc in the PLUS ONE slit.
2. Turn OFF the power, close the door, and while pressing the
[CLEAR]
and [PLUS ONE] buttons simultaneously, turn ON the power
again.
3. Press the
[CHECK]
button, and set the loading mode.
4. Press the
±
button and chuck the disc.
5. Adjust the magnet assembly and magnet holder so that A=B as shown in the figure.
DISC  HOLDER  A  ALIGMENT
1. Check that there is no disc in the unit and then turn ON the power.  Open the door, and set a disc in the PLUS ONE slit.
2. Turn OFF the power, close the door, and while pressing the
[CLEAR]
and
[PLUS ONE]
buttons simultaneously, turn ON the power
again.
3. Press the
[CHECK]
button, and set the loading mode.
4. Press the
±
button and chuck the disc.
5. Press
or
±
button to stop the disc holder A slightly away from the disc.
6. Rotate and adjust the adjusting screw so that the center of the disc and that of the disc holder coincide.
Magnet ASSY
Magnet ASSY
Magnet holder
Screw (For adjustment)
A   B
Disc
Disc
Disc holder A
Disc holder A
a  b
a = b
Screw (For adjustment)
– 15 –
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the fol-
lowing checks.
S Curve Check
Procedure :
1. Press the
I
/
u
button and turn ON the power supply.
2. Open the front cover, and press the 
[PLUS ONE]
 button.
3. Set the disc (YEDS-18) into the “PLUS ONE” slit.
4. Close the front cover, and chuck the disc.
5. Press the
I
/
u
button and turn OFF the power.
6. Connect the oscilloscope to TP (FE) of the BD board.
7. Connect TP (ADJ) of the DISPLAY board and the ground with
a lead wire.
8. Press the
I
/
u
button and turn ON the power.
9. The first track will be played back automatically. When the
[CHECK]
button is pressed, “S JI” will be displayed on the
fluorescent indicator tube, and focus search will be repeated.
10. Check the oscilloscope waveform (S-curve) is symmetrical be-
tween A and B. And confirm peak to peak level within 1.8 
±
0.6 Vp-p.
11. Turn OFF the power, and remove the lead wire connected at
step 7.
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the brightness
to obtain best waveform.
RF Level Check
Procedure :
1. Press the
I
/
u
button and turn ON the power supply.
2. Open the front cover, and press the 
[PLUS ONE]
 button.
3. Set the disc (YEDS-18) into the “PLUS ONE” slit.
4. Close the front cover, and chuck the disc.
5. Press the
I
/
u
button and turn OFF the power.
6. Connect the oscilloscope to TP (RF) of the BD board.
7. Connect TP (ADJ) of the DISPLAY board and the ground with
a lead wire.
8. Press the
I
/
u
button and turn ON the power.
9. Playback the fifth track of the disc.
10. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
11. Turn OFF the power, and remove the lead wire connected at
step 7.
Note:
A clear RF signal waveform means that the shape “
” can be clearly
distinguished at the center of the waveform.
E-F Balance (Traverse) Check
The procedure for this checking method differs for when a general
remote control unit is used and not used.
When a general remote commander is used:
1. Press the
I
/
u
button and turn ON the power supply.
2. Open the front cover, and press the 
[PLUS ONE]
 button.
3. Set the disc (YEDS-18) into the “PLUS ONE” slit.
4. Close the front cover, and chuck the disc.
5. Press the
I
/
u
button and turn OFF the power.
6. Connect the oscilloscope to TP (TE) of the BD board.
7. Connect TP (ADJ) of the DISPLAY board and the ground with
a lead wire.
8. Press the
I
/
u
button and turn ON the power.
9. Playback the fifth track of the disc.
10. Press the 
[3]
 button on the remote commander. (The tracking
servo and the sledding servo are turned OFF.)
11. Check the level B of the oscilliscope's waveform and the A (DC
voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than 
±
 10%
12. Press the 
[8]
 button on the remote control unit. (The tracking
servo and sledding servo are turned ON.) Confirm the C (DC
voltage) is almost equal to the A (DC voltage) is step 11.
13. Turn OFF the power, and remove the lead wire connected at
step 7.
SECTION  6
ELECTRICAL  ADJUSTMENTS
BD board
TP (FE)
TP (VC)
+
oscilloscope
symmetry
within 1.8 
±
 0.6Vp-p
A
B
S-curve waveforms
BD board
TP (RF)
TP (VC)
+
oscilloscope
(AC range)
level :  1.6 
±
0.3
 
Vp-p
0.2
 
VOLT/DIV :  200mV
TIME/DIV :  500ns
RF signal waveform
BD board
TP (TE)
TP (VC)
+
oscilloscope
Center of the waveform
level :  1.3 
±
 0.5 Vp-p
A (DC voltage)
0 V 
Traverse waveform
C (DC
voltage)
Tracking servo 
Sled servo
           ON
Tracking servo 
Sled servo
          OFF
Traverse waveform
0 V
– 16 –
When a general remote commander is not used:
1. Solder lead wires to TP (DVDD) and TP (TOFF) on the BD
board severally.
2. Connect the oscilloscope to TP (TE) of the BD board.
3. Press the
I
/
u
button and turn ON the power supply.
4. Open the front cover, and press the
[PLUS ONE]
button.
5. Set the disc (YEDS-18) into the “PLUS ONE” slit.
6. Close the front cover, and chuck the disc.
7. Playback the fifth track of the disc.
8. Short-circuit the lead wire connected at step 1. (The tracking
servo is turned OFF)
9. Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than 
±
 10%
10. Disconnect the lead wire short-circuited at step 8. (The track-
ing servo is turned ON.) Confirm the C (DC voltage) is almost
equal to the A (DC voltage) is step 8.
11. Turn OFF the power, and remove the lead wire connected at
step 1.
RF PLL Free-run Frequency Check
Procedure :
1. Connect the frequency counter to TP (PCK) of the BD board.
2. Press the
I
/
u
button and turn ON the power supply.
3. Open the front cover, and press the 
[PLUS ONE]
 button.
4. Set the disc (YEDS-18) into the “PLUS ONE” slit.
5. Close the front cover, and chuck the disc.
6. Playback the fifth track of the disc.
7. Confirm that reading on frequency counter is 4.3218 MHz 
±
30 kHz.
About RV502 on the AUDIO board
RV502 of the AUDIO board requires no adjustments. Please note
that it should be dixed to mechanical center position when you
moved and do not know origin position.
Adjustment Location:
[ BD BOARD ] — CONDUCTOR SIDE —
[ DISPLAY BOARD ] — CONDUCTOR SIDE —
[ AUDIO BOARD ] — COMPONENT SIDE —
frequency counter
BD board
TP (PCK)
C (DC
voltage)
Tracking servo 
           ON
Tracking servo 
          OFF
Traverse waveform
0 V
CNP801
IC801
CNP804
TP
(ADJ)
IC102
TP
(TOFF)
TP
(DVDD)
TP
(PCK)
TP
(RF)
TP
(TE)
TP
(FE)
TP
(VC)
CN101
CN103
CN102
IC101
BD board
TP (FE)
TP (VC)
+
oscilloscope
T501
NO503
CN841
CN801
CN811
CN501
RV502 (No Adjustment)
Center of the waveform
level :  1.3 
±
 0.5 Vp-p
A (DC voltage)
0 V 
Traverse waveform
Page of 48
Display