DOWNLOAD Sony CDP-CX300 / CDP-CX350 / CDP-CX691 Service Manual ↓ Size: 4.59 MB | Pages: 59 in PDF or view online for FREE

Model
CDP-CX300 CDP-CX350 CDP-CX691
Pages
59
Size
4.59 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cdp-cx300-cdp-cx350-cdp-cx691.pdf
Date

Sony CDP-CX300 / CDP-CX350 / CDP-CX691 Service Manual ▷ View online

– 9 –
3-5. BACK PANEL ASSEMBLY
3-6. CDM ASSEMBLY
0
 Back panel
4
 Connector
     (CN84)
1
 Connector (CN991)
9
 Guide (main)
 Main board
2
 Connector 
     (CN903)
3
 Connector 
     (CN901)
7
 Two screws (BVTP 3x8)
!™
 Two screws (BVTP 3x8)
 Two screws (BVTP 3x8)
8
 Two screws 
     (BVTP 3x8)
6
 Two screws (BVTP 3x8)
5
 Three screws 
     (BVTP 3x8)
5
 Screw 
     (BVTP 3x8)
8
 Power board
4
 Screw 
6
 Two screws 
     (BVTP 3x8)
2
 Two screws 
     (BVTP 3x8)
9
 Three screws 
     (BVTP 3x8)
1
 Three screws 
     (BVTP 3x8)
3
 Three screws 
     (BVTP 3x8)
7
 Four screws 
     (BVTP 3x8)
0
 Bracket(top)
 
CDM assembly
– 10 –
ALL ERASE
This mode is used for clearing information such as the title memo.
Do not execute if information such as the title memo is not to be
erased.
Procedure:
While pressing the  CLEAR  button with the power OFF, press the
1/u   button and turn on the power.
The fluorescent display tube displays “ALL ERASE” and all memo-
ries will be cleared.
AGING MODE
• Mode which repeatedly changes and plays back discs automati-
cally in the unit.
• It will repeat aging as long as no errors occur.
• If an error occurs during aging, it will stop all servos, motors, etc.
instantaneously, display the error number, and stop operations.
However, the stopping conditions differ according to whether the
unit is equipped with the “self-protection function during errors”
described later.
The function serves to maintain the state of the unit when errors
occur.
SECTION 4
SERVICE MODE
Mode name
ALL ERASE
AGING MODE
LOARDING AGING MODE
TABLE AGING MODE
DOOR POP UP AGING MODE
TABLE LOTATION MODE
TITLE MEMO SHIFT MODE
MODEL NAME DISPLAY
MICROPROCESSOR VERSION DISPLAY
ALL LIT MODE
MECHANISM ADJUSTMENT MODE
SHIPMENT MODE
TITLE MEMO RECORDING CHECK MODE
Power supply state
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Button operation
  CLEAR  +  
1
  GROUP 1  +  
§
 OPEN/CLOSE  +  +100
  GROUP 2  +  
§
 OPEN/CLOSE  +  +100
  GROUP 3  +  
§
 OPEN/CLOSE  +  +100
  GROUP 4  +  
§
 OPEN/CLOSE  +  +100
  GROUP 5  +  
§
 OPEN/CLOSE  +  +100
  GROUP 7  +  
§
 OPEN/CLOSE  +  +100
  GROUP 1  +  
·
  +  +100
  GROUP 2  +  
·
  +  +100
  GROUP 3  +  
·
  +  +100
  GROUP 4  +  
·
  +  +100
  GROUP 5  +  
·
  +  +100
  GROUP 6  +  
·
  +  +100
Remarks
Note 1
Used in adjustment
Note 1
Note 1
Note 1
Do not execute unless with a proper reason, otherwise the memory of the title memo recorded by the customer will be erased.
The title memo recording check mode is not required for servicing. Do not execute.
SPECIAL FUNCTION
This unit is provided with several service modes.
Details are shown in the following table.
1. Disc change
2. Load in
3. TOC read
4. Access of last track
5. 3 second playback
6. Access of first track
7. 3 second playback
8. Load out
9. FRONT COVER open
10. FRONT COVER close
1. No. 60
2. No. 240
3. No. 180
4. No. 300
5. No. 120
Sequence of Aging Mode
$
$
$
$
$
$
$
$
$
Order of Disc Change
 (1 cycle takes 3 minutes)
$
$
$
$
$
$
$
$
– 11 –
Aging Procedure
1. Turn ON the power of the unit. Press the  
§ OPEN/CLOSE  and
open the front cover.
2. Change the  COMMAND MODE  switch (S901) on set to  CD1 .
3. Press the  AGING START  button of the remote commander for
aging mode (J-2501-123-A).
4. When the disc set mode is set, the  
·  and  P  LEDs blink.
5. Rotate the  DISC/CHARACTER  dial. The slits (No. 60, 120,
180, 240, 300) for setting the discs will come forward. Insert the
discs into these slits. Do not set the discs in other slits.
6. Set whether the self-protection function during errors is equipped
with the unit. Press the  REPEAT  button. If “REPEAT” is dis-
played on the Fluorescent indicator tube, it means the function
is provided. If “REPEAT” is not displayed, it means the function
is not provided.
Error Display
7. Press the  
·  button.
8. The  
·  LED blinks, the aging mode is set, and aging is started.
9. The aging cycle lasts 3 minutes. If errors occur during aging, the
error number will be displayed on the Fluorescent indicator tube.
(Refer to the following table for the details of the errors.)
10. Aging will be repeated as long as no errors occur.
11. After each aging cycle, the number displayed on the Fluorescent
indicator tube will increase.
12. To end aging, disconnect the power cord from the outlet.
NOTE: As an alternative to steps 2 and 3, press the   GROUP 1
button,  
§OPEN/CLOSE  button, and  +100  button at the
same time.
Err 01
Err 02
Err 03
Err 04
Err 05
Err 06
Err *1
Err *2
Err *3
Err *4
Err *5
Err *6
Err *7
No disc in the specified slit
Disc in other slits
Table motor current over
No table sensor input
Load in timeover
Load out timeover
Access timeover
High speed search NG
Q data read error
BU operation (from focus search to until signal can be read) timeover
GFS monitor error
Focus cannot be imposed by focus search
Auto focus bias adjustment cannot be performed
Contents
Code number
Name
DISC sensor check 1
DISC sensor check 2
Table operation check 1
Table operation check 2
Loading operation check 1
Loading operation check 2
BU related check 1
BU related check 2
BU related check 3
BU related check 4
BU related check 5
BU related check 6
BU related check 7
Error code
The * numbers mean the following according to the state of the unit during aging
2 : From chucking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback
Special Aging Mode Functions
The aging mode is provided with the following convenient func-
tions
• Disc setting mode (*1)
• Selection of presence of protection function during error (*2)
• Count function of aging cycle (*3)
*1 Disc setting mode:
5 discs are set before setting the aging mode. This mode makes
the setting of these discs more easy.
*2 Self protection function during errors:
Function which voluntarily corrects errors which occur during
normal operations by retries.
If this function is not provided, all operations will be stopped
without retiring. It is suitable for checking errors with low re-
producibility.
If this function is provided, and errors can be corrected by re-
tries, aging will be continued without stopping.
*3 Aging cycle count function:
Functions which displays the number of agings carried out on
the Fluorescent indicator tube  in numbers. One aging cycle con-
sists of five discs.
1DISC
CD1
DISC
120
AGED 10
number of agings
number of disc table
  
  
1 2 0
E 0 1
#
  
Aging cycle
number
Error code
Disc number
with error
Disc number
when aging
180
  
– 12 –
LOADING AGING MODE
• This mode is used for repeating loading operations continuously.
• Aging will be performed continuously unless an error occurs.
• When an error occurs, the error code will be displayed on the
fluorescent indicator tube.
Procedure:
1. Set a disc in the DISC 1 slit.
2. With the power ON, while pressing the  GROUP 2  button and
§ OPEN/CLOSE  button, press the  +100  button.
3. When the mode is set, both the  
·   and  P   indicators will
start to blink.
4. When the  
·   button is pressed, only the  ·   indicator will
blink and aging starts.
5. To end the mode, press the  
1/u   button or disconnect the power
cord from the outlet.
The error codes displayed during operations and when errors occur
are the same as the 
“AGING MODE”
 described earlier.
TABLE AGING MODE
• This mode is used for rotating the table randomly.
• Aging will be performed continuously unless an error occurs.
• When an error occurs, the error code will be displayed on the
fluorescent indicator tube.
Procedure:
1. Set discs in slits 1, 2, 99, 100, and 200.
2. With the power ON, while pressing the  GROUP 3  button and
§ OPEN/CLOSE  button, press the  +100  button.
3. When the mode is set, both the  
·   and  P   indicators will
start to blink.
4. When the  
·   button is pressed, only the  ·   indicator will
blink and aging starts.
5. To end the mode, press the  
1/u   button or disconnect the power
cord from the outlet.
During aging, operations will be carried out sequentially in the or-
der of No. 1, No. 2, No. 100, No. 99, and No. 200 slits.
The error codes displayed during operations and when errors occur
are the same as the 
“AGING MODE”
 described earlier.
DOOR POP UP AGING MODE
• This mode is used for performing aging of the CD pop up part
and door open/close.
It is used for checking if operations are performed normally.
Method:
1. To select a slot to be aged, press the 
§ OPEN/CLOSE  button
and rotate the  DISC/CHARACTER  knob with the front door
opened to select a number.
2. With the power ON, while pressing the  GROUP 4  button and
§ OPEN/CLOSE  button, press the  +100  button.
3. When the  
·  button is pressed, aging starts, and door open/
close and up/down operations of the pop up part are performed
continuously.
4. To end the mode, press the  
1/u  button.
If DISC is not selected at step 1, aging will be performed at the 192
slot.
The number of times aging is performed will be displayed on the
fluorescent indicator tube during operations.
TABLE ROTATION MODE
• This mode is used for electrical adjustments. Refer to the section
on Electrical Adjustments.
TITLE MEMO SHIFT MODE
• This mode is used for writing title memo information recorded in
this unit in a different unit.
Use it for transferring disc memo contents written by the cus-
tomer to the new units when replacing the unit, etc.
Connection:
Procedure:
1. Connect two units using the  CONTROL A1 II  connection cord
shown in the figure.
2. Set the  COMMAND MODE  switch of the copy source unit to
CD3  and the  COMMAND MODE  switch of the copy desti-
nation unit to  CD1 .
3. With the power on, while pressing the  GROUP 7  button and
§ OPEN/CLOSE  button of the copy destination unit, press
the  +100  button.
4. When the data has been transferred, the fluorescent indicator
tube displays “complete” for about 1 second.
MODEL NAME DISPLAY
Model names can be displayed on the fluorescent indicator tube
for checking the microprocessor model setting, etc.
Procedure:
With the power ON, while pressing the  GROUP 1  and 
· but-
tons, press the  +100  button.
The model name is displayed on the fluorescent indicator tube.
MICROPROCESSOR VERSION DISPLAY
The microprocessor version can be displayed on the fluorescent
indicator tube.
Procedure:
With the power ON, while pressing the  GROUP 2  and 
· but-
tons, press the  +100  button.
The microprocessor version is displayed on the fluorescent indica-
tor tube.
ALL LIT MODE
This mode is used for lighting the whole fluorescent indicator
tubes and LEDs.
Procedure:
With the power ON, while pressing the  GROUP 3  and 
· but-
tons, press the  +100  button.
Both the fluorescent indicator tubes and LEDs will light up com-
pletely.
To end this mode, press the  
1/u  mode.
CONTROL A1 
II
 connection cord provided
Flow of data
This unit
(Copy source)
Another unit
(Copy destination)
COMMAND MODE: CD3
COMMAND MODE: CD1
CONTROL A1 
II
$
$
$
$
Page of 59
Display