– 17 –
6-2. ELECTRICAL ADJUSTMENT
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when
the signal level is low than specified value with the following
checks.
S-Curve Check
Procedure :
1. Chuck the disc (YEDS-18) beforehand, and disconnect the power
cord from the outlet.
2. Connect oscilloscope to test point TP (FE1) on BD board.
3. Connect test point TP1 (ADJ) on MAIN board to ground with
lead wire.
4. The ADJ mode is set when the power cord is inserted into the
outlet and power is supplied.
5. The fifth track is played automatically.
6. Press the  CHECK  button.
7. Check the oscilloscope waveform (S-curve) is symmetrical be-
tween A and B. And confirm peak to peak level within 3±1 Vp-p.
S-curve waveform
8. Pressing the  
1/u  button stops the output of the waveform (s
curve).
9. After check, remove the lead wire connected in step 3.
Note : • Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the bright-
ness to obtain best waveform.
Adjustment Location: BD board
RF Level Check
Note: A clear RF signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
RF signal waveform
Adjustment Location: BD board
E-F Balance Check
Procedure :
1. Chuck the disc (YEDS-18) beforehand, and disconnect the power
cord from the outlet.
2. Connect oscilloscpe to test point TP (TE) on BD board.
3. Connect test point TP1 (ADJ) on MAIN board to ground with
lead wire.
4. The ADJ mode is set when the power cord is inserted into the
outlet and power is supplied.
5. The fifth track is played automatically.
6. Press the  GROUP 3  button. (The tracking servo and the sled-
ding servo are turned OFF.)
7. Check the level B of the oscilliscope's waveform and the A (DC
voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse waveform
8. Press the  GROUP 8  button. (The tracking servo and sledding
servo are turned ON.) Confirm the C (DC voltage) is almost
equal to the A (DC voltage) is step 7.
Traverse waveform
Procedure :
1. Connect oscilloscope to test point TP (RF) on BD board.
2. Turn Power switch on.
3. Put disc (YEDS-18) in to play the number five track.
4. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
oscilloscope
BD board
TP (FE1)
TP (VC)
symmetry
A
B
Within 3 
±
 1 Vp-p
oscilloscope
BD board
TP (RF)
TP (VC)
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.2         Vp-p
+0.25
–0.20
oscilloscope
BD board
TP (TE)
TP (VC)
0V
level : 1.3 
±
 0.6 mVp-p
A (DC voltage)
Center of the waveform
B
0V
C (DC 
voltage)
Tracking servo
Sledding servo
        OFF
Tracking servo
Sledding servo
        ON
9. Disconnect the lead wire of TP1 (ADJ) connected in step 2.
Adjustment Location: MAIN board
– 18 –
1. Connect the oscilloscope to Pins 1, 2, and 3 of CN506 of the
MAIN board.
2. Check that no discs are loaded in the unit.
3. With the power ON, while pressing the  GROUP 5  and
§ OPEN/CLOSE  buttons, press the  +100  button. The disc
table starts to rotate in the clockwise direction.
4. Loosen the fixing screw, move the mounting board (SENSOR),
and secure the mounting board (SENSOR) at the point the H
portion of the P.T waveform comes the center of the H portion
of the D.S waveform.
Disc Sensor Adjustment
Be sure to perform this adjustment after sensor adjustment in ME-
CHANICAL ADJUSTMENT.
Connection:
Waveform:
5. Rotate the  DISC/CHARACTER  knob in the counterclockwise
direction and the disc table starts to rotate in the same direction.
Check that the waveform at this time is the same as that in step
4. If larger by a considerable extent, rotate the  DISC/CHAR-
ACTER  knob in the clockwise direction and the disc table starts
to rotate in the same direction. Repeat from step 4.
6. Rotate RV501 of the MAIN board and adjust so that the H and L
portions of the D.S waveform become the same.
Fixing screw
Mounting board (SENSOR)
D.S: Pin 
1
T.P: Pin 
3
GND: Pin 
2
oscilloscope
D.S
GND
T.P
MAIN board
CN506
D.S
P.T
D.S
P.T
Should be at the center
D.S
Adjust so that these widths
become the same.
Adjustment Location: MAIN board
– 19 –
Adjustment Location :
[ BD BOARD ] – Side B –
IC102
IC103
TP
(RF)
TP
(FE1)
TP
(TE)
TP
(VC)
[ MAIN BOARD ] – Component Side –
RV501
DISC SENSOR 
ADJUSTMENT
1
3
CN506
TP2 (AFADJ) R516
TP1 (ADJ)
R517
1
44
34
33
23
22
12 11
IC502
– 20 –
SECTION  7
DIAGRAMS
7-1. CIRCUIT BOARDS LOCATION
MAIN board
JACK board
POWER board
LED board
T . SENS board
D . SENS (OUT) board
D . SENS (IN) board
D . SW board
D . MOTOR board
JOG board
SW board
SW 2 board
L.T. MOTOR board
BD board
DISPLAY board
KEY board
Page of 59