DOWNLOAD Sony CDP-CE275 / CDP-CE375 Service Manual ↓ Size: 2.95 MB | Pages: 41 in PDF or view online for FREE

Model
CDP-CE275 CDP-CE375
Pages
41
Size
2.95 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cdp-ce275-cdp-ce375.pdf
Date

Sony CDP-CE275 / CDP-CE375 Service Manual ▷ View online

11
CDP-CE275/CE375
Buttons and Corresponding Button Numbers
Button
Button Number or Display
DISC1
12
DISC2
11
DISC3
10
DISC4
9
DISC5
8
PLAY MODE
20
PEAK SEARCH
19
FADER
18
REPEAT
17
TIME
16
H (PLAY)
Partial lighting 1
X (PAUSE)
Partial lighting 2
x (STOP)
All lit
EX-CHANGE
35
DISC SKIP
36
m
24
M
25
EDIT
26
CHECK
27
CLEAR
28
AMS (push)
37
AMS (turn)
When rotated clockwise: The music calendar
numerals light up in ascending order.
When rotated counterclockwise: The music
calendar numerals light up in descending
order.
R
Light altemately
r
1
SEC
STEP
MIN
PEAK
TRACK
DISC
2 3
4
5
6
7 8
9 10
11 12 13 14 15
16 17 18 19 20
ALL1DISCS
 PROGRAM
 SHUFFLE
REPEAT 1
EDIT
TIME
FADE
A B
All lit
SEC
MIN
TRACK
Partial lighting 1
1
STEP
PEAK
DISC
2 3
4
5
6
7 8
ALL1DISCS
1
3
5
7
9
11
13
15
18
20
Partial lighting 2
2
4
6
8
10
12
14
16 17
19
R
Light altemately
r
Ver 1.1 2001.07
12
CDP-CE275/CE375
AGING  MODE
For the aging mode, three modes of all mode, disc table mode, and loading mode are available.
This set has the Aging mode for operation check of the mechanism deck.
• If a failure occurred
The aging operation stops and a faulty status is displayed on the fluorescent indicator tube.
• If no failure occurs
The aging operation continues repeatedly.
Note:
Do not use the test disc when performing aging.
Aging will not be performed properly if discs with tracks shorter than 4 seconds are used.
Procedure:
1. Press the 
[POWER]
 button and turn ON the power.
2. Set discs on all trays.
(More than two discs if five are not available)
3. All mode:
Press the 
[CHECK]
[PLAY MODE]
 and
x
buttons at the same time.
Disc table mode:
Press the 
[CHECK]
[PLAY MODE]
 and 
[SKIP]
 buttons at the same time.
Loading mode:
Press the 
[CHECK]
[PLAY MODE]
 and 
[EX-CHANGE]
 buttons at the same time.
4. Aging starts, and the fluorescent indicator tube will display the following.
5. To exit the mode, press the 
[POWER]
 button to turn OFF the power.
Code No.
Status
All mode
Disc table
Loading
Display in
Display in
mode
mode
Normal operation
case of failure
0
CLOSE (Tray closed)
a
a
A-0
Err 0
1
TOC reading
a
a
a
A-1
Err 1
2
Access to last track
a
A-2
Err 2
3
Play of last track (3 sec)
a
Counter display
Err 3
4
EX OPEN (Tray opened while chucking)
a
a
A-4
Err 4
5
EX SKIP (Disc tray rotated)
a
A-5
Err 5
6
EX CLOSE (Tray closed)
a
a
A-6
Err 6
7
Access to first track
a
A-7
Err 7
8
Play of first track (3 sec)
a
Counter display
Err 8
9
OPEN (tray opened)
a
a
A-9
Err 9
A
DISC SKIP (Disc tray rotated,
a
a
A-A
Err A
and next disc was selected)
The discs are selectie in the order of DISC1 
DISC2 
 DISC3 
 DISC4 
 DISC5 
 DISC1 
 .... Empty trays are skipped.
But the order is random in the disc table mode.
MECHANISM  DECK  CHECK  MODE
For the mechanism deck check mode, two modes of disc table mode and loading mode are available.
In the mechanism deck check mode, the disc table turning time and the loading time in each section are measured and displayed.
Procedure:
Disc table mode:
Press the 
[POWER]
 switch while pressing
H
[    OPEN/CLOSE]
 and  
[REPEAT]
 buttons simultaneously.
Loading mode:
Press the 
[POWER]
 switch while pressing
H
[    OPEN/CLOSE]
 and  
[TIME]
 buttons simultaneously.
A
A
Display contents
Mode
Check command
Display
Disc table mode
0: Right one turn
r 12.5
Table turning
1: Left one Turn
L 10.2
(
 time measurement 
)
2: Measurement end
r 12.5
3: Undefined
4: Star position
Sta
– –.–
5: Open 
 Close
CLo 10.2
6: Close 
 BU up
UP
0.7
Table mode
7: BU up 
 EX open
EoP
6.2
Loading time
8: EX open 
 EX close
ECL 10.3
(
 measurement 
)
9: EX close 
 BU down
don
1.2
A: BU down 
 Open
oPn
9.3
FF: Measurement end
CLo 10.2
Ver 1.1 2001.07
13
CDP-CE275/CE375
Ver 1.1  2001.07
Note:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use PATD-012 disc (4-225-203-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S Curve Check
Connection:
Procedure:
1.
Set the test disc (PATD-012). Disc chucking operation is
complete, then press the 
[POWER]
 button to turn the power
off.
2.
Connect an oscilloscope to test point TP (FE1) and TP (VC)
on the BD board.
3.
Connect between test point TP (ADJ) on the MAIN board and
GND by lead wire.
4.
Press the  
[POWER]
 button to turn the power on and enter the
ADJ mode.
Then playback the number two track automatically, press the
x
button to stop the playback.
5.
Press the  
[CHECK]
 button actuate the focus search. (actuate
the focus search when disc table is moving in and out)
6.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 2 ± 1
Vp-p.
S-curve waveform
Note:
 • Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Checking Location: BD board
RFDC Level Check
Connection:
+
BD board
TP (FE1)
TP (VC)
oscilloscope
A
B
symmetry
within 2 
±
 1 Vp-p
+
BD board
TP (RFDC)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 1.15 
±
 0.35 Vp-p
VC
Procedure:
1.
Set the test disc (PATD-012). Disc chucking operation is
complete, then press the 
[POWER]
 button to turn the power
off.
2.
Connect an oscilloscope to test point TP (RFDC) and TP (VC)
on the BD board.
3.
Connect between test point TP (ADJ) on the MAIN board and
GND by lead wire.
4.
Press the  
[POWER]
 button to turn the power on and enter the
ADJ mode, then playback the number two track automatically.
5.
Confirm that oscilloscope waveform is clear and check the level
of between RFDC top and VC is correct or not.
Note:
A clear RFDC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
       RFDC signal waveform
Checking Location: BD board
RFAC Level Check
Connection:
Procedure:
1.
Set the test disc (PATD-012). Disc chucking operation is
complete, then press the 
[POWER]
 button to turn the power
off.
2.
Connect an oscilloscope to test point TP (RFAC) and TP (VC)
on the BD board.
3.
Connect between test point TP (ADJ) on the MAIN board and
GND by lead wire.
4.
Press the  
[POWER]
 button to turn the power on and enter the
ADJ mode, then playback the number two track automatically.
5.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
Note:
A clear RFAC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
       RFAC signal waveform
Checking Location: BD board
+
BD board
TP (RFAC)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 1.35 
±
 0.4 Vp-p
SECTION  5
ELECTRICAL  ADJUSTMENTS
14
CDP-CE275/CE375
Ver 1.1 2001.07
E-F Balance Check
Connection:
Procedure:
1.
Set the test disc (PATD-012). Disc chucking operation is
complete, then press the 
[POWER]
 button to turn the power
off.
2.
Connect an oscilloscpe to test point TP (TE1) and TP (VC) on
the BD board.
3.
Connect between test point TP (ADJ) on the MAIN board and
GND by lead wire.
4.
Press the  
[POWER]
 button to turn the power on and enter the
ADJ mode, then playback the number two track automatically.
5.
Press the 
[TIME]
 button.  (The tracking servo and the sledding
servo are turned OFF)
6.
Check the level B of the oscilliscope waveform and the A (DC
voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse Waveform
7.
Press the 
[TIME]
 button. (The tracking servo and sledding servo
are turned ON)
Confirm the C (DC voltage) is almost equal to the A (DC
voltage) is step 6.
Traverse Waveform
Checking Location: BD board
+
BD board
TP (TE1)
TP (VC)
oscilloscope
0V
B
level: 1.15 
±
 0.5 Vp-p
Center of 
the waveform
A (DC 
voltage)
0V
Tracking servo
Sled servo
ON
C (DC 
voltage)
Tracking servo
Sled servo
OFF
Checking Location:
– BD BOARD (Conductor Side) –
TP 
(RFDC)
TP
 (FE1)
TP
 (VC)
IC131
IC150
IC101
TP
 (TE1)
TP 
(RFAC)
Page of 41
Display

Click on the first or last page to see other CDP-CE275 / CDP-CE375 service manuals if exist.