13
3-7.  TUNER (FM/AM),  IR-REPEATER  BOARD
 IR-REPEATER board
 wire (flat type)
 
(9 core) (US, Canadian models (MAIN board: CN1013/tuner))/
 
(11 core) (AEP, UK models (MAIN board: CN1012/tuner))
 tuner (FM/AM)
 two screws
 (BVTP3 
× 8)
 two screws
 (BVTP3 
× 8)
 connector (CN151)
 two fabric non wovens
 (5T25)
3-8.  POWER  BOARD
 bracket (HT)
 POWER board
 fabric non woven (15T25)
 clip bracket
 seven screws
 (BVTT3 
× 6)
 eight screws
 (BVTT3 
× 6)
 three screws
 (BVTT3 
× 6)
 screw
 (BVTT3 
× 6)
SA-WIS100/SS-IS15
14
3-9.  IO  BOARD
 wire (flat type) (21 core)
(CN701)
 wire (flat type) (15 core)
 (CN903)
 IO board
 connector
 (CN703)
 three screws
 (BVTT3 
× 6)
 eight screws
 (BVTP3 
× 8)
3-10.  SPEAKER  BOARD,  SAIR  BOARD
RB SPEAKER
 board
RE bracket (S-AIR)
RK holder (S-AIR)
RL SAIR board
RI two screws
 (BVTP2.6)
 three screws
 (BVTP3 
× 8)
RT two screws
 (BVTP3 
× 8)
RG two screws
 (BVTP3 
× 8)
RH cushion (35T100)
 fabric non woven (15T25)
 shield (S-AIR)
 terminal
 two screws
 (BVTT3 
× 6)
 two screws
 (BVTT3 
× 6)
 two screws
 (BVTT3 
× 6)
R lead wire connector
(CN101)
SA-WIS100/SS-IS15
15
SECTION  4
TEST  MODE
1.  TEST  MODES  OTHER  THAN  THE  TEST  MENU
These are executable test mode even if not entering the test menu.
1-1. Cold Reset
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the three buttons [
INPUT SELECTOR
], [
VOLUME –
] and 
[
?/1
] simultaneously.
3.  The messages “COLD RESET” is displayed on the fl uorescent 
indicator tude, and power supply is turned off.
2.  TEST  MODES  IN  THE  TEST  MENU
These are the test modes done in the test menu.
Setting method of the test menu:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the two buttons [INPUT SELECTOR] and [VOLUME 
+] simultaneously for 5 seconds.
3.  The message “TEST MENU” appears on the fl uorescent indi-
cator tube and enter the test menu.
2-1. Panel Test
Procedure:
1.  Enter the test menu.
2.  Press the [VOLUME +] [VOLUME –] button to select the 
“PANEL”, and press the [INPUT SELECTOR] button.
3.  LEDs and all segments in fl uorescent indicator tube are lighted 
up. The display of the fl uorescent indicator tube is repeated in 
order of all lighting 
→ display pattern 1 → display pattern 2.
4.   When all segments in fl uorescent indicator tude are lighted up 
in the state of step 3, press the [VOLUME +] button and model 
information is displayed on the fl uorescent indicator tube.
 
Each time the [VOLUME +] button is pressed, the display 
changes from destination information, MC version in this or-
der, and returns to the model information display.
 
Each time the [PRESET +] button is pressed, the version and 
date are switched.
5.  In the state of step 3, press the [VOLUME –] button and “K 0” 
is displayed on the fl uorescent indicator tube.
 
“K 0” value increases whenever a button on the set is pressed. 
However, once a button has been pressed, it is no longer taken 
into account.
 
All buttons on the set are pressed, “OK” and “K 6” are alter-
nately displayed on the fl uorescent indicator tube.
6.  To release from this mode, press the [
?/1
] button.
2-2. AMP Test
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-3.  Tuner Factory Preset
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-4. VACS Display
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-5. VACS On/off
Procedure:
1.  Enter the test menu.
2.  Press the [VOLUME +] [VOLUME –] button to select the 
“VACS ONOFF”, and press the [INPUT SELECTOR] button.
3.  On/off of VACS changes.
2-6.  DSP Halt Mode
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-7.  DSP Status Display
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-8.  A.CAL Test Disp
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-9.  DSP IRAM MODE
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-10. HDMI Version Display
Procedure:
1.  Enter the test menu.
2.  Press the [VOLUME +] [VOLUME –] button to select the 
“HDMI VER”, and press the [INPUT SELECTOR] button.
3.  The version of HDMI is displayed on the fl uorescent indicator 
tube.
2-11.  Digital Media Port Test
Procedure:
1.  Connect the DMPORT check jig (P/N: J-2501-309-A) with the 
DMPORT jack (CN702) on the IO board.
2.  Press the [
?/1
] button to turn the power on.
3. Confi rm that both LEDs of the DMPORT check jig lights. 
(Confi rmation the power supply line)
4.  Press the [INPUT SELECTOR] button to select the “DMPORT”.
5.  Enter the test menu.
6.  Press the [VOLUME +] [VOLUME –] button to select the 
“DMPORT CHK”, and press the [INPUT SELECTOR] but-
ton.
7.  The message “DMPORT OK”, appears on the fluorescent indi-
cator tube and enter the digital media port test mode.
 
(Confirmation of communication line)
 
When “NO DETECT”. and “UART.TO” are displayed on 
the fluorescent indicator tube, confirm the connection of the 
DMPORT check jig, and enter the mode again.
8.  To a pinjack of the DMPORT check jig input information rele-
vant to audio signal (sine-wave 1.0V rms) and composite video 
signal (white 100% 1.0Vp-p, color bar, etc.).
9. Confi rm the output of speakers and monitor TV. (Confi rmation 
of analog signal)
10. To release from this mode, press the [
?/1
] button.
2-12. DMPORT Device Test
Procedure:
1.  Connect the DMPORT check jig (P/N: J-2501-309-A) with the 
DMPORT jack (CN702) on the IO board.
2.  Enter the test menu.
3.  Press the [VOLUME +] [VOLUME -] button to select the 
“DMPORT DEV”, and press the [INPUT SELECTOR] but-
ton.
4.  LED on the jig lights.
color
pattern
generator
DMPORT
check jig
(Part No.:
J-2501-309-A)
J001
AF
oscillator
set
(SA-WIS100)
TV
monitor
FL/FR
speaker
IO board
CN702
SPEAKER board
TB101
IO board
J901
SA-WIS100/SS-IS15
16
2-13. S-AIR Test
Procedure:
1.  Enter the test menu.
2.  Press the [VOLUME +] [VOLUME –] button to select the “S-
AIR TEST”, and press the [INPUT SELECTOR] button.
3.  The message “POWER”appears on the fl uorescent  indicator 
tube and enter the S-AIR test mode.
4.  Press the [
M
] [
m
] button on the remote commander to select 
the “POWER” and press the [ENTER] button on the remote 
commander.
5.  The output power is displayed on the fl uorescent indicator tube 
and the it can be changed by pressing the [
M
] [
m
] button on the 
remote commander.
6.  Press the [
<
] button on the remote commander, returns to the 
previous screen.
7.  Press the [
M
] [
m
] button on the remote commander to select the 
“NAMG” and press the [ENTER] button on the remote com-
mander.
8.  The NAMG setting value is displayed on the fl uorescent indi-
cator tube and the it can be changed by pressing the [
M
] [
m
button on the remote commander.
9.  Press the [
<
] button on the remote commander, returns to the 
previous screen.
10.  Press the [
M
] [
m
] button on the remote commander to select the 
“VER.CHECK” and press the [ENTER] button on the remote 
commander.
11. The microcomputer version of the S-AIR product connected 
with the set is displayed.
12. Press the [
<
] button on the remote commander, returns to the 
previous screen.
13. Press the [
M
] [
m
] button on the remote commander to select 
the “ENC KEY” and press the [ENTER] button on the remote 
commander.
14. The on/off setting of the encryption key is displayed on the 
fl uorescent indicator tube and the it can be changed by pressing 
the [
M
] [
m
] button on the remote commander.
15. Press the [
<
] button on the remote commander, returns to the 
previous screen.
16. To release from this mode, press the [
?/1
] button.
2-14. Radio 
Test
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-15.  DMPORT Source Display
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-16.  DMPORT Target Display
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-17. Cold Reset
Procedure:
1.  Enter the test menu.
2.  Press the [VOLUME +] [VOLUME –] button to select the 
“COLD RESET”, and press the [INPUT SELECTOR] button.
3.  The message “COLD RESET.” appears on the fl uorescent in-
dicator tube, power supply is turned off.
SECTION  5
ELECTRICAL  CHECK
FM  AUTO  STOP  CHECK
Procedure:
1.  Turn the power on.
2.  Insert the following signal from Signal Generator to FM an-
tenna input directly.
*  Carrier Freq :  A = 87.5 MHz, B = 98 MHz, C = 108 MHz
 Deviation 
75 
kHz
 Modulation 
kHz
 
ANT input  :  35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the set. You 
cannot use video cable for checking.
 
  Please use SG whose output impedance is 75 ohm.
3.  Set to FM tuner function and scan the input FM signal with 
automatic scanning.
4. Confi rm that input Frequency of A, B and C delected and auto-
matic scanning stops.
The stop of sutomatic scanning means “The statioon signal is re-
ceived in good condition”.
generator
SET
+
75
Ω