Sharp LC-70LE836E Service Manual ▷ View online

LC-70LE835E/RU, 836E/S, 838E
5 – 11
4) Volume fixed [VOLUME FIXED]
5) Volume fixed level [VOLUME FIXED LEVEL]
6) Remote control operation [RC BUTTON]
7) Main Unit Operation [PANEL BUTTON]
Option
“VARIABLE”, “FIXED”, “ACCTRL” or “AC/RCCTRL” (loop enabled)
Default “VARIABLE”
Function •
VARIABLE
FIXED
AC CTRL
AC/RC CTRL 
: The volume is not fixed.
: The volume is fixed to the value adjusted in the volume fixed level.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in the 
  case of the AC-ON only.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in 
  any case.
  (AC
→ON, remote control→ON, main utit's key→ON)
Exception
In the adjustment process, the volume can be set to any level regardless of this setting.
Disabled key when 
setting to FIXED
VOLUME UP/DOWN    [both remote control and main unit]
MUTE 
*
Main units's key is enabled for operating menu.
Remarks 
[MAXIMUM VOLUME] has priority to [VOLUME FIXED]
*
When setting to FIXED, Maximum volume is fixed.
The volume of the headphones is fixed.
When setting to “FIXED”, the volume is not displayed in operating Disabled key.
In menu operation, the main unit’s keys (Vol (+/-)) are enabled.
Volume level graphic be omitted to volume level number.
In setting to FIXED, ONVOL of On TIMER is not selected (Eliminate Item)
In setting to AC/RC CTRL, ONVOL of On TIMER i is not selected (Eliminate Item)
Option
0~60 (loop disabled)
Default 20
Function
The volume is fixed to the adjusted value (the main unit’s speaker only).
Exception
In the adjustment process, the volume can be set to any level regardless of this setting.
Remarks 
When [VOLUME FIXED] is set to “VARIABLE”, the setting cannot be changed.
VOLUME can be abbreviated to VOL.
Option
“RESPOND”, “NORESPOND” or “LIMITED” (loop enabled)
Default “RESPOND”
Function 
The operation of the remote control’s keys is set.
     RESPOND
     NO RESPOND
     LIMITED 
: The remote control’s keys in the normal state are enabled.
: The remote control’s keys in the normal state are disabled.
  The POWER key (RECEPTION/STANDBY key) is also disabled.
: Only a part of keys (CHANNEL, etc.) is enabled and other keys are disabled.
Exception
All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or 
Public Mode setting screen.
Remarks 
The enable keys when setting to “LIMITED” are depended on Model.
Option
“RESPOND” or “NO RESPOND” (loop enabled)
Default “RESPOND”
Function •
RESPOND 
NO RESPOND
: The main unit’s keys are enabled.
: The main unit’s keys are disabled excluding the POWER key (RECEPTION/STANDBY key).
Exception
The start operation in the adjustment process mode, inspection mode are enabled regardless of this setting.
All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or 
Public Mode setting screen.
For the models with the MENU key on the main unit, menu operation is possible regardless of the setting during the 
initial setting when the power is turned on for the first time.
LC-70LE835E/RU, 836E/S, 838E
5 – 12
8) Menu operation [MENU BUTTON]
9) AV position fixed [AV POSITION FIXED]
10)  OSD display [ON SCREEN DISPLAY]
Option
“RESPOND” or “NO RESPOND” (loop enabled)
Default “RESPOND”
Function
The MENU key on the main unit and remote control is decided whether it is enabled or disabled.
Exception
RESPOND
NO RESPOND 
: The manu key is enabled.
: The manu key is disabled.
: All the keys are enabled regardless of this setting while entering the process mode, inspection 
  mode or Public Mode setting screen.
Disabled key excluding 
Menu key when setting 
to not default
All the direct transition keys to menu display. (AUTO PRESET, MANUAL MEMORY and others)
*
These keys does not exist according to the model.
Remarks 
When setting to “NO RESPOND”
For the models with the MENU key on the main unit, menu operation is possible regardless of the setting while the 
initial setting when the power is turned on for the first time.
Option
“VARIABLE” or “FIXED” (loop enabled)
Default “VARIABLE”
Function •
VARIABLE
FIXED
: AV position is not fixed.
: AV position is fixed.
: The image/sound adjustment items in the menu are fixed in the selected state.
: When receiving “AV POSITION” of the remote control, only the actual state is displayed, and 
  setting is not changed.
Remarks 
When receiving the sound select direct keys (AV POSITION key, OPC, DOLBY key, etc.), only the actual state is 
displayed; no setting is changed.
*
These keys does not exist according to the model.
The settings for the Public mode are retained after the personal data is initialized, each item for the AV position and 
image/sound adjustment are not initialized.
Option
“YES”, “NO” or “LIMITED” (loop enabled)
“LIMITED” is looped only in case of need (destination).
Default “YES”
Function •
YES
NO
LIMITED
: OSD is displayed.
: The following OSD is not displayed.
  Registration, setting, adjustment menu, channel call, volume bar, and input select.
: Only a part of OSD (CH call: “New Information” etc...) is not displayed.
Key which may be 
enabled
(Example of the confus-
ing key)
It is OK in the case that simple input select occur or the original state returns soon automatically.
Disabled key when 
setting to not default
When setting to “NO”, the keys which is related to visibility of the screen and sound cannot be used.
STILL IMAGE, SCREEN DISPLAY, OFF TIMER, AV POSITION, BRIGHTNESS SENSOR, SCREEN SIZE SELECT, 
AUTO PRESET, MANUAL MEMORY, IMAGE SELECT, SOUND SELECT, LANGUAGE, Closed caution
*
Disabled keys dependeds on the models. 
Remarks 
When setting to “NO”,
                                     ON TIMER (Watching reservation) is cleared.
                                     OFF TIMER “SLEEP” is cleared.
*
These items does not exist according to the model.
When setting to “NO”,
                                  These Displays (Version-up, Public mode setting screen, Pass Word input screen of Public 
                                  Mode, the adjustment process mode, K mark of inspection mode) are enabled regardless of 
                                  this setting.
LC-70LE835E/RU, 836E/S, 838E
5 – 13
11)  Start mode [INPUT MODE START]
Example of option: “NORMAL”, “TVD (002TV)”, “INPUT1”, “INPUT2”, “INPUT3”, “HDMI1”, “HDMI2”, “HDMI3”, “HDMI4”.
12)  Input fixed [INPUT MODE FIXED]
13)  Speaker ON/OFF selection [LOUD SPEAKER]
14)  Remote control path through [RC PATH THROUGH]
Option
“NORMAL” or “Input source 1 (input selection or channel)” ... (loop enabled)
Default “NORMAL”
Function 
Which kinds of input source or channel is decided when the power turning on.
     NORMAL
: The content of the last memory is followed.
Remarks
When setting to not Normal, ON TIMER (Watching reservation) has priority.
When setting to “NORMAL”, [INPUT MODE FIXED] is set to “VARIABLE” and [INPUT MODE FIXED] is prohibited to 
select. (selection impossible.)
Option
“VARIABLE”, “FIXED”, “ACCTRL” or “AC/RCCTRL” (loop enabled)
Default VARIABLE
Function
     VARIABLE
     FIXED
     AC CTRL
     AC/RC CTRL
: If [INPUT MODE START] is set to Normal, input mode is not fixed.
: When “INPUT MODESTART” is active, it is impossible to switch to another channel or input 
  source.
: When “INPUT MODESTART” is active the unit starts at the input mode which is selected when 
  power is turned on in the case of the AC-ON only.
: When “INPUT MODESTART” is active the unit starts at the input mode which is selected 
  when power is turned on in any case.
  (AC
→ON, remote control→ON, main utit's key→ON)
Disabled key when 
setting to “FIXED” 
CHANNEL (+/-), DIRECT CHANNEL buttons, FLASHBACK, INPUT SELECT, TV/VIDEO, AUTO PRESET, 
MANUAL MEMORY, i.LINK, DIRECTINPUTSELECT, ATV, DTV, EPG, RADIO etc...
Remarks
If [INPUT MODE START] is Normal, this function cannot be set.
Set to “VARIABLE” automatically.
When setting to “FIXED”,
The item related to the channel setting and input selection in Menu are not displayed.
ON TIMER (Watching reservation) is not active.
*
These items does not exist according to the model.
Option
“ON” or “OFF” (loop enabled)
Default ON
Function
     ON
     OFF
: The sound from the speakers is output.
: The sound from the speakers is not output even if the headphones are not used.
Remarks
When the VOL (+/-) key is pressed, the mute icon is displayed for 4 seconds.
For the MUTE key and sound-related keys, caution is displayed.
For the headphones, normal operation is possible.
Option
“OFF”, “ON: TVRCE” or “ON: TVRCD” (loop enabled)
Default OFF
Function 
The item decide whether the signal received by the remote control’s light-receiving section is output to the blankpin (9pin) 
of RS232C.
     OFF
     ON: TVRCE
     ON: TVRCD 
: This function is not active.
: This function is active, and remote control is active, too.
: This function is active, but remote control is not active.
Exception
In the case of “ON: TV RCD”, the start operation in the adjustment process mode, inspection mod are enabled 
                               regardless of this setting.
In the case of “ON: TV RCD”, all the keys are enabled regardless of this setting while entering the adjustment process 
                               mode, inspection mode or Public mode setting screen.
Remarks 
*
Remote control path through does not exist according to the model.
LC-70LE835E/RU, 836E/S, 838E
5 – 14
15)  232C power ON control [232C POWON]
16)  Public mode setting [PUBLIC MODE]
9. Copy Mode
1. Starting the Copy Mode
1)  Method of needing password
a) While holding down the “INPUT” and “Volume UP” keys on the set at once, plug in the AC power cord to turn on the power.
b) Display the Pass Word input screen.
After a while, value of Enter password appears on the screen.
Operation procedure
The initial input position is the digit at the left end.
For the numeric keys “0” to “9” of R/C, key input is accepted.
Input of the other keys is prohibited.
Change “—” to “ ” by inputting the numeric key at the input position, and shift the input position rightward one digit.
When three digits are completely input, the Pass Word is judged.
c) Check the Pass Word by inputting three digits.
If the Pass Word “3” “6” “9”, it shifts to the Copy Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
2. Exiting the Copy Mode Setting screen
There is following way to exit the Copy Mode setting screen.
Turn off the power. (Unplug the AC power cord from the outlet to forcibly turn off the power.)
3. Basic operation in the Copy Mode
Option
“ENABLE” or “DISABLE” (loop enabled)
Default DISABLE
Function 
The item decide whether Power ON by the 232C command is enabled/disabled in the standby state.
The same function as 232C command “RSPW”.
     ENABLE
     DISABLE
: POWR0001 is always enabled.
: Start-up may be impossible at POWR0001.
  (If the 232C command reception module is set to OFF, the command is invalid.)
Option
“OFF” or “ON” (loop enabled)
Default OFF
Function 
The item decide whether Public mode setting menu are enabled or disabled.
The same item as [PUBLIC MODE] in the adjustment process menu.
     OFF
     ON
: Public mode is not active.
: Public mode is active.
Remarks 
Each operation of the Public mode is impossible unless this item is set to ON.
CH (+/-) or Cursor (
/
)
Movement to the selected item.
Decision (ok)
Execution
Enter password
Enter password
Enter password
Page of 78