DOWNLOAD Sharp LC-65XS1E (serv.man3) Service Manual ↓ Size: 1.33 MB | Pages: 23 in PDF or view online for FREE

Model
LC-65XS1E (serv.man3)
Pages
23
Size
1.33 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / Adjustment
File
lc-65xs1e-sm3.pdf
Date

Sharp LC-65XS1E (serv.man3) Service Manual ▷ View online

LC-52XS1E/RU/LC-65XS1E/RU
3 – 9
32/46
[M OPC3]
1
OPC LDUTY 23
Disclosure 
2
OPC LDUTY 24
Disclosure 
3
OPC LDUTY 25
Disclosure 
4
OPC LDUTY 26
Disclosure 
5
OPC LDUTY 27
Disclosure 
6
OPC LDUTY 28
Disclosure 
7
OPC LDUTY 29
Disclosure 
8
OPC LDUTY 30
Disclosure 
9
OPC LDUTY 31
Disclosure 
10
OPC LDUTY 32
Disclosure 
33/46
[M ADL1]
1
OPC33 ADLEVEL 0
Disclosure 
2
OPC33 ADLEVEL 1
Disclosure 
3
OPC33 ADLEVEL 2
Disclosure 
4
OPC33 ADLEVEL 3
Disclosure 
5
OPC33 ADLEVEL 4
Disclosure 
6
OPC33 ADLEVEL 5
Disclosure 
7
OPC33 ADLEVEL 6
Disclosure 
8
OPC33 ADLEVEL 7
Disclosure 
9
OPC33 ADLEVEL 8
Disclosure 
10
OPC33 ADLEVEL 9
Disclosure 
11
OPC33 ADLEVEL 10
Disclosure 
12
OPC33 ADLEVEL 11
Disclosure 
34/46
[M ADL2]
1
OPC33 ADLEVEL 12
Disclosure 
2
OPC33 ADLEVEL 13
Disclosure 
3
OPC33 ADLEVEL 14
Disclosure 
4
OPC33 ADLEVEL 15
Disclosure 
5
OPC33 ADLEVEL 16
Disclosure 
6
OPC33 ADLEVEL 17
Disclosure 
7
OPC33 ADLEVEL 18
Disclosure 
8
OPC33 ADLEVEL 19
Disclosure 
9
OPC33 ADLEVEL 20
Disclosure 
10
OPC33 ADLEVEL 21
Disclosure 
11
OPC33 ADLEVEL 22
Disclosure 
35/46
[M ADL3]
1
OPC33 ADLEVEL 23
Disclosure 
2
OPC33 ADLEVEL 24
Disclosure 
3
OPC33 ADLEVEL 25
Disclosure 
4
OPC33 ADLEVEL 26
Disclosure 
5
OPC33 ADLEVEL 27
Disclosure 
6
OPC33 ADLEVEL 28
Disclosure 
7
OPC33 ADLEVEL 29
Disclosure 
8
OPC33 ADLEVEL 30
Disclosure 
9
OPC33 ADLEVEL 31
Disclosure 
36/46
[M V6THE]
1
V6 OS THERMO 1
83 (52), 79 (65)
Disclosure 
2
V6 OS THERMO 2
101 (52), 97 (65)
Disclosure 
3
V6 OS THERMO 3
114 (52), 108 (65)
Disclosure 
4
V6 OS THERMO 4
122 (52), 121 (65)
Disclosure 
5
V6 OS THERMO 5
137 (52), 135 (65)
Disclosure 
6
V6 OS THERMO 6
155 (52), 152 (65)
Disclosure 
7
V6 OS THERMO 7
174 (52), 175 (65)
Disclosure 
37/46
[M V5THE]
1
V5 OS THERMO 1
83 (52), 79 (65)
Disclosure 
2
V5 OS THERMO 2
101 (52), 97 (65)
Disclosure 
3
V5 OS THERMO 3
114 (52), 108 (65)
Disclosure 
4
V5 OS THERMO 4
122 (52), 121 (65)
Disclosure 
5
V5 OS THERMO 5
137 (52), 135 (65)
Disclosure 
6
V5 OS THERMO 6
155 (52), 152 (65)
Disclosure 
7
V5 OS THERMO 7
174 (52), 175 (65)
Disclosure 
Page
Line
Item
Description
Remarks (adjustment detail, etc.)
LC-52XS1E/RU/LC-65XS1E/RU
3 – 10
38/46
[M BLCTL TEMP]
1
BL TEMP1
Disclosure 
2
BL TEMP2
Disclosure
3
BL TDUTY
Disclosure
39/46
[M EEP SET]
1
MONITOR TIME OUT
ON
Disclosure
2
MONITOR MAX TEMP
53
Disclosure
3
MONITOR EEP READ / WRITE
WRITE
Disclosure
4
MONITOR EEP ADR
0x  0
Disclosure
5
MONITOR EEP DATA
0x  0
Disclosure
40/46
[M TESTPTRN]
1
LCD TEST PATTERN
OFF
Pattern with built-in LCD controller display.   
2
LCD AGI TEST PATTERN
OFF
Pattern with built-in LCD controller display.   
3
LCD EVA TEST PATTERN
OFF
Pattern with built-in LCD controller display.   
4
FRA TEST PATTERN
OFF
Pattern with built-in LCD controller display.   
5
PSF TEST PATTERN
OFF
41/46
[DCLP COMP]
1
YG_CLPWDY_COMP525P
default
Disclosure
2
RB_CLPWDC_COMP525P
default
Disclosure
3
AYCLPON_COMP525P
default
Disclosure
4
SLLSHR_GAIN_COMP525P
0
Disclosure
5
YG_CLPWDY_COMP1125I
default
Disclosure
6
RB_CLPWDC_COMP1125I
default
Disclosure
7
AYCLPON_COMP1125I
default
Disclosure
8
SLLSHR_GAIN_COMP1125I
0
Disclosure
9
YG_CLPWDY_COMP750P
default
Disclosure
10
RB_CLPWDC_COMP750P
default
Disclosure
11
AYCLPON_COMP750P
default
Disclosure
12
SLLSHR_GAIN_COMP750P
0
Disclosure
42/46
[DCLP DVI]
1
YG_CLPWDY_DVIA
default
Disclosure
2
RB_CLPWDC_DVIA
default
Disclosure
3
AYCLPON_DVIA
default
Disclosure
4
SLLSHR_GAIN_DVIA
0
Disclosure
5
FILTERMODE
default
Disclosure
43/46
[IRSS]
1
IrSS MODE
ROM
Disclosure
2
OPERATION MODE
AUTO
Disclosure
3
TEMP THREADSHOLD
175
Disclosure
4
NOISE THREADSHOLD
0
Disclosure
5
INSPECTION MENU MODE
NOMAL
Disclosure
44/46
[FR REGI]
1
KEY LOCK(1217)
Enter
Key input lock
2
KOUTEI AREA ALL CLEAR
Adjustment value clearness in all areas in process
3
A MODE AREA CLEAR
Adjustment value clearness of process A mode
4
BACKUP AREA CLEAR
Adjustment value clearness in process backup area
5
B MODE AREA CLEAR
Adjustment value clearness of process B mode
6
EXECUTION
Clear execution
45/46
[MEM CLEAR]
1
READ/WRITE
READ
Read/Write
2
SLAVE ADDRESS
FRA
Slave address
3
REGISTER ADDRESS
0x  0
Register address
0x  0
4
WRITE DATA
0x  0
Writing data
0x  0
5
READ DATA
0x  0
Reading data
0x  0
Page
Line
Item
Description
Remarks (adjustment detail, etc.)
LC-52XS1E/RU/LC-65XS1E/RU
3 – 11
46/46
[ETC]
1
POWER MEASURE (Quick ON)
Enter
2
POWER MEASURE (Quick OFF)
Enter
3
EEP SAVE
OFF
Writing setting values in EEPROM.
4
EEP RECOVER
OFF
Reading setting values from EEPROM.
5
LED TCON DATA SAVE
OFF
Writing LED TCON DATA in EEPROM
6
LED TCON DATA RECOVER
OFF
Reading LED TCON DATA from EEPROM
7
MONITOR SUB ERROR CAUSE 
RESET
OFF
Reset of monitor sub error cause
8
STANDBY CAUSE RESET
OFF
Reset stand by cause.
9
WALL PICTURE DATA 
NONE
10
WALL PICTURE DATA MODE 
ERASE
11
TIME COUNTER
2
12
TIME COUNTER RESET
OFF
13
PRODUCT EEP ADR
0x 0
Don't touch when serving (for producer of factory)
14
PRODUCT EEP DATA
0x 0
Don't touch when serving (for producer of factory)
Page
Line
Item
Description
Remarks (adjustment detail, etc.)
LC-52XS1E/RU/LC-65XS1E/RU
3 – 12
[4] Display Adjustment
1. Panel Part Adjustment
1. COMB-BIAS Adjustment
2. EDID writing
3. Initialization to factory settings (When factory settings is initialized by STB, it is unnecessary. )
After a factory setting,  It ends with the AC power supply OFF.
Adjustment 
point 
Adjustment conditions
Adjustment procedure
1
COMB-BIAS 
Adjustment
A visual check
1. Please start a set.
2. Enter the adjustment process mode. (Please refer to the [2]nd clause..)
3. Move the cursor to [VCOM ADJ] on page 3/46.
4. Press the OK key. then, you can check that the pattern for adjustment is displayed.
5. Adjust so that the flicker for the central part of a screen becomes the minimum using the (+) 
and (-) key of the volume of R/C.
6. If it will be in the optimal state by the 5th clause, press the OK key and turn off a pattern.
[CAUTION]
Operate a monitor independently and adjust him.
2
Upper and lower 
brightness differ-
ence adjustment
(Only 65 inch)
A visual check
1. Please start a set.
2. Enter the adjustment process mode. (Please refer to the [2]nd clause..)
3. Move the cursor to [LCD LUMA ADJ] on page 3/46.
4. Press the OK key. then, you can check that the gray flat pattern for adjustment is displayed.
5. Adjust so that the Upper and lower brightness difference for the central part of a screen  
becomes the minimum using the (+) and (-) key of the volume of R/C.
6. If it will be in the optimal state by the 5th clause, press the OK key and turn off a pattern.
[CAUTION]
The brightness of the screen in the under changes by the upper and lower brightness differ-
ence adjustment.
Operate a monitor independently and adjust him.
Adjustment point 
 Adjustment conditions
Writing procedure
1
EDID writing
Adjustment process mode
[EDID writing with adjustment process mode]
• Enter the adjustment process mode.
•  Move the cursor to [HDMI EDID WRITE] on page 3/46.
• Press the "OK" key to remote control. 
• After a while, If “EDID WRITE OK" is displayed, the setting is completed. 
“CAUTION”
The data based on model discrimination information in the LB harness (IF substrate ~ 
LCD_A3C substrate) is described to EEPROM. Confirm the thing that the inspected set 
is corresponding to the size of the panel on the process page 1. 
(When not written in, HDMI does not function.)
CAUTION:  After factory setting is set, Please do not turn on the power supply. 
If you turn on the power supply, Please execute the factory setting again. 
Please do not carry out power supply OFF with remote control.
Adjustment point 
Adjustment conditions
 Adjustment procedure
1
Factory settings 
Please end by MAIN 
POWER key "OFF."
(See to below caution)
[Factory setting with adjustment process mode]
• Enter the adjustment process mode.
• Move the cursor to [INDUSTRY INIT] on page 2/46.
and press the [OK] key.
• After a while, “INDUSTRY INIT SUCCESS” is displayed in the upper part of the 
screen and the setting is completed. 
When succeeding: Background color (green)
When failing: Background color (red)
The following items are initialized in the factory setting.
1) Last state of operation.
2) The contents of an error are cleared.
(Back light operation time is not cleared.)
How to exit from adjustment process mode.
After adjustments, to exit the adjustment process mode, turn off the MAIN power key.
When the power is turned off with the remote control, unplug the AC power cord and plug it back in.
Page of 23
Display