Sharp LC-45GD1E (serv.man27) Service Manual ▷ View online

32
TU-45GD1E
LC-45GD1E
Unused(For one apparatus)
Unused(For one apparatus)
CVIC-generated internal pattern display
SEINE-generated internal pattern display
Data copy for initialization: Prohibited
Permission of card recording by external input: Prohibited
Saving adjustment value in storage area
Retrieving adjustment value from storage area
Prohibited
Reset of standby cause: Prohibited
Destination setting: Prohibited
Page
Item
Explanation
13/16
[M GAMMA 6 G]
MONITOR G GAMMA 1
MONITOR G GAMMA 2
MONITOR G GAMMA 3
MONITOR G GAMMA 4
MONITOR G GAMMA 5
MONITOR G GAMMA 6
GAMMA     WRITE
OFF
GAMMA     RESET
OFF
14/16
[M GAMMA 6 B]
MONITOR B GAMMA 1
MONITOR B GAMMA 2
MONITOR B GAMMA 3
MONITOR B GAMMA 4
MONITOR B GAMMA 5
MONITOR B GAMMA 6
GAMMA     WRITE
OFF
GAMMA     RESET
OFF
15/16
[PATTERN]
CVIC PATTERN
OFF
GPU RETTERN
OFF
16/16
[ETC]
DATA COPY FOR INIT
ON
CARD REC INPUT
1
EEP SAVE
OFF
EEP RECOVER
OFF
AUTO INSTALLATION SW
1
STANDBY CAUSE RESET
OFF
SYS MODEL COUNTRY
AUTO
33
TU-45GD1E
LC-45GD1E
Key
Function 1 (when on the left side of a page)
Function 2 (when changing a numeric value)
Cursor UP
                '
Cursor DOWN
                "
Cursor RIGHT
                |
Cursor LEFT
                \
ENTER
INPUT
CH_UP
(CH (ù))
CH_DOWN
(CH (Ù))
VOL_UP
(VOL (+))
VOL_DOWN
(VOL (–))
ADJUSTMENT PROCEDURE (LC-45GD1E)
The adjustment values are set to the optimum conditions at the factory before shipping.  If a value should
become improper or an adjustment is required due to part replacement, make an adjustment according to the
following procedure.
Caution: When replacing the following units, make sure to prepare the new units loaded with updated
software.
DIGITAL TUNER unit:
DVI/HDMI unit:
Display adjustment procedure
1. Adjustment procedure
Enter the adjustment process mode 
➝ Adjust VLS BIAS (15V) voltage  ➝ Adjust GRAY LEVEL (14.2V)
voltage  
➝ Adjust COM BIAS  ➝ Adjust background
2 Entering the adjustment process mode (regardless of whether or not the system cable is connected)
[Caution] When entering the adjustment process mode, do not change the set values other
than those for the basic adjustment described below. The system may be damaged beyond
recovery.
Moving up by one item or moving to the previous
page (when at the top)
Moving down by one item or moving to the next
page (when at the bottom)
Moving to the right by one item
Moving to the left by one item
Test pattern off
Moving to the next page
Moving up by one item or moving to the previous
page (when at the top)
Moving down by one item or moving to the next
page (when at the bottom)
Moving to the right by one item
Moving to the left by one item
Incrementing the adjustment value by one
Decrementing the adjustment value by one
Moving to the right by one item
Moving to the left by one item
Executing the item
Moving to the next page
Incrementing the adjustment value by one
Decrementing the adjustment value by one
Moving to the right by one item
Moving to the left by one item
3. Basic operation (Remote controller operation)
(1) Unplug the AC cord with the monitor power SW "ON".
(2) While holding down the "VOL + " and "V CH" keys at a time, plug in the monitor AC cord. The unit starts
up in the "monitor process mode".
Page 1 of the "Monitor adjustment mode" appears.
(The same displays appear on the left and right sides of the screen.)
* To exit the adjustment process mode, turn off the power.
34
TU-45GD1E
LC-45GD1E
4. Adjustment Procedure
4-1. VLS BIAS (15V) voltage adjustment
Go to "VLS BIAS" with the cursor (UP/DOWN) keys and select the value with the cursor (LEFT/RIGHT)
keys.
Connect a digital voltage meter to TP4827 (TL4843) on the LCD_CONT_TOP PWB and adjust the value
with the cursor (UP/DOWN) keys to 15.00V±0.05V.
4-2. GRAY LEVEL (14.2V) voltage adjustment
Go to "GRAY LEVEL" with the cursor (UP/DOWN) keys and select the value with the cursor (LEFT/
RIGHT) keys.
Connect a digital voltage meter to TP4501 (TL4501) on the LCD_CONT_TOP PWB and adjust a value
with the cursor (UP/DOWN) keys to 14.20V±0.05V.
Make sure to adjust the value accurately as this power supply voltage will be used as a reference voltage
for the gradation voltage.
4-3. COM BIAS adjustment
Shift to the [COM BIAS] item with the cursor UP/DOWN key and select a numeric value with the cursor
RIGHT/LEFT key.
Changing the numeric value with the cursor UP/DOWN key will make appear the test pattern.  Make an
adjustment so that the flicker near the center of the screen is minimized.
4-4. Background adjustment
(1)
Connect the AVC center and monitor for the background adjustment.
(2)
Display the adjustment confirmation screen (gray scale).
(3)
Go to "PATTERN" with the cursor (UP/DOWN) keys and press "ENTER".
Go to "PATTERN PAGE2" with the cursor (DOWN) key.
(4)
Adjust ADJ to 6 and press "ENTER".
(5)
Set the 6th point to the designated gradation and adjust RGB to obtain the standard value for the 6th
point.
(6)
Set the 1st point to the designated gradation and calculate the G set value of the 1st point using the
following formula: G initial value of the 1st point x (G adjustment value of the 6th point/928) (rounding off
fractions). Then adjust RB to obtain the standard value of the 1st point.
(7)
Set the 2nd point to the designated gradation and calculate the G set value of the 2nd point using the
following formula: G initial value of the 2nd point x (G adjustment value of the 6th point/928) (rounding off
fractions). Then adjust RB to obtain the standard value of the 2nd point.
(8)
Set the 3rd point to the designated gradation and calculate the G set value of the 3rd point using the
following formula: G initial value of the 3rd point x (G adjustment value of the 6th point/928) (rounding off
fractions). Then adjust RB to obtain the standard value of the 3rd point.
(9)
Set the 4th point to the designated gradation and calculate the G set value of the 4th point using the
following formula: G initial value of the 4th point x (G adjustment value of the 6th point/928) (rounding off
fractions). Then adjust RB to obtain the standard value of the 4th point.
(10) Set the 5th point to the designated gradation and calculate the G set value of the 5th point using the
following formula: G initial value of the 5th point x (G adjustment value of the 6th point/928) (rounding off
fractions). Then adjust RB to obtain the standard value of the 5th point.
(11) Adjust CALC to 1 and calculate. Confirm that the adjustment has been made correctly to exit.
[North America]
Standard value 1: x=0.295, y=0.305 [Minolta CA-110] (216 gradations)
Standard value 2: x=0.295, y=0.305 [Minolta CA-110] (352 gradations)
Standard value 3: x=0.295, y=0.305 [Minolta CA-110] (528 gradations)
Standard value 4: x=0.295, y=0.305 [Minolta CA-110] (656 gradations)
Standard value 5: x=0.295, y=0.305 [Minolta CA-110] (800 gradations)
Standard value 6: x=0.291, y=0.300 [Minolta CA-110] (928 gradations)
35
TU-45GD1E
LC-45GD1E
8.Lamp error detection
8-1.Feature description
This liquid-crystal colour TV incorporates a lamp error detection feature (lamp error detection) that automatically
turns OFF the power for safety under abnormal lamp or lamp circuit conditions.
If anything is wrong with the lamp or lamp circuit or when the lamp error detection feature is activated for some
reason, the following will result.
1 The power of TV main body is turned OFF about six seconds after it is turned ON.  (The power LED on
the front of the TV turns red from green and keeps blinking in red (ON for 250ms and OFF for 1sec).)
2 If 1 occurs five times consecutively, it becomes impossible to turn ON the power.  (The power LED
keeps blinking in red (ON for 250ms and OFF for 1sec).)
8-2.Measures
1).Checking with lamp error detection OFF
While the “MAIN POWER” switch is off, hold down the “P(Ù)” and “       (+)” keys and then turn the “MAIN
POWER” on. The display will run in the “Display process mode” (“<K>” will appear.).
      If there is a problem with a lamp or a lamp circuit, the lamp will go out. (The power LED is green.)
      Then, you can check the operation to see if the lamp and lamp circuit are abnormal.
2).Resetting the lamp error count
After you have finished checking whether the lamp and lamp circuit are abnormal, reset the lamp error
count. If a lamp error is detected five consecutive times, the power cannot be turned on.
      Therefore, move to the “L ERR RESET” line, the fourth line on the first page of the“Display adjustment
      mode”, using the “Cursor '/"” key. Then, reset the “L ERR RESET” value using the “Cursor Û / û” key.
      In this case, press the “Cursor '/"” key to reset it to "0".
Then perform operation checking and check that the lamp error detection feature is not activated.
table of contents of process mode page 0
Normal values of individual displays
Reset to "0"
SERVICE      S
   GRAYLEVEL
   COMBIAS
   VLSBIAS
   L ERR RESET
   LCD
   PATTERN
   MOTOR AND FAN
   OTHER
   VER M301
32/37GD1E
100
155
041
    0
CEEPD