Sharp LC-39LE751EK (serv.man3) Service Manual ▷ View online
45
LC-39/50LE750
LC-39/50LE751
LC-39/50LE752
10. INPUT TV MODE PROGRAM NUMBER [1-999]
If value is “0”, TV should start in the last program number selected by user if in the previous control ATV / DTV
is selected, this is the normal user TV behavior. If value is different from “0”, TV should starts in the specifi ed
program number when it is switched on.
is selected, this is the normal user TV behavior. If value is different from “0”, TV should starts in the specifi ed
program number when it is switched on.
11. INPUT MODE FIXED [VARIABLE ↔ FIXED]
“FIXED” has been selected, any channels and input modes other than those selected at the start mode cannot
be picked up.
be picked up.
12. RC PATH THROUGH [ON ↔ OFF] (Need additional Hardware)
When ON and RS-232 circuitry is really assembled , in pin #9 of RS-232 socket appears a feedback of the
remote signal (3.3v logic type).
remote signal (3.3v logic type).
13. HOTEL MODE [ON ↔ OFF]
If ON has been selected the HOTEL MODE is activated.
14. RS-232C POWER ON [ENABLE ↔ DISABLE] (Need additional Hardware)
When this option is set to “ENABLE” it means that TV should be able to be switched on from standby mode
through a RS232 command.
through a RS232 command.
15. HDMI LEVEL POWER ON [ENABLE ↔ DISABLE] (Need additional Hardware)
Enabling this option, the polling of HDMI signal presence in a given HDMI input is being monitored.
[TV in ON mode] If there isn’t HDMI signal present, after some seconds TV should go to standby
[TV in standby mode] If there is HDMI signal present, TV should switch on.
[TV in ON mode] If there isn’t HDMI signal present, after some seconds TV should go to standby
[TV in standby mode] If there is HDMI signal present, TV should switch on.
16. COMMIT
Select Commit and press OK to apply the change.
17. RESET
Cancel all Public Mode settings. (It returns to the factory settings)
8.3. Public Mode Menu.
8. Public Mode (Hotel mode) ( continued )
Item
Description
Remarks (adjustment details, etc.)
PUBLIC MODE
PUBLIC MODE Submenu
Press ">" or "OK" to enter to PUBLIC MODE Submenu
1
Power On fi xed
Variable
Press ";" or "<" to change Variable/Fixed then press "OK"
2
Maximum volume
100
Enter number of maximum volume
3
Volume fi xed
Variable
Press ";" or "<" to change Variable/Fixed then press "OK"
4
Volume fi xed level
33
Enter number of maximum volume
5
RC button
Respond
Press ";" or "<" to change Respond/No respond then press "OK"
6
Panel button
Respond
Press ";" or "<" to change Respond/No respond then press "OK"
7
Menu Button
Respond
Press ";" or "<" to change Respond/No respond then press "OK"
8
On Screen Display
Yes
Press ";" or "<" to change Yes/No then press "OK"
9
Input mode start
Normal
Press ";" or "<" to change Normal/ATV/DTV/HDMI1.. then press "OK"
10
Input TV mode program
number
number
0
Enter number of program
11
Input mode fi xed
Variable
Press ";" or "<" to change Variable/Fixed then press "OK"
12
RC path through
Off
Press ";" or "<" to change On/Off then press "OK" (Need additional Hardware)
13
Hotel mode
Off
Press ";" or "<" to change On/Off then press "OK"
14
RS232C Power On
Disable
Press ";" or "<" to change Enable/Disable then press "OK" (Need additional
Hardware)
Hardware)
15
HDMI Level Power On
Disable
Press ";" or "<" to change Enable/Disable then press "OK" (Need additional
Hardware)
Hardware)
16
Commit
Press "OK" to confi rm
17
Reset
Press "OK" to return to factory settings
46
LC-39/50LE750
LC-39/50LE751
LC-39/50LE752
9. SMART LOADER
Description.
The Smartloader is a function implemented in the service software of SEE designed LE750 series intended to easily
replicate the user settings of one TV into another. These settings include (but not restricted to): picture and audio, tun-
ing set-up, language and country selection, PIN, child locked programs… Factory adjustments are not copied as they
are different for every TV.
The Smartloader makes possible the user data to be stored in a memory device connected to the USB terminal of the
TV that is used as reference and later load those data into other TVs by using their respective USB terminal.
replicate the user settings of one TV into another. These settings include (but not restricted to): picture and audio, tun-
ing set-up, language and country selection, PIN, child locked programs… Factory adjustments are not copied as they
are different for every TV.
The Smartloader makes possible the user data to be stored in a memory device connected to the USB terminal of the
TV that is used as reference and later load those data into other TVs by using their respective USB terminal.
How it works.
In reference TV:
In reference TV:
1. Insert a memory device in the USB slot.
2. Enter in service mode, select SmartLoader (Clone TV) menu.
3. Press “OK”.
4. Select “Save data” and press OK in the remote control.
5. Wait until “OK:0” is displayed, the fi le has been successfully created in the root directory of the memory device.
In case of error, an explanation message is shown.
2. Enter in service mode, select SmartLoader (Clone TV) menu.
3. Press “OK”.
4. Select “Save data” and press OK in the remote control.
5. Wait until “OK:0” is displayed, the fi le has been successfully created in the root directory of the memory device.
In case of error, an explanation message is shown.
In TV to be cloned:
1. Insert a memory device with a fi le in it obtained following the above procedure.
2. Enter in service mode, select SmartLoader menu.
3. Select “Load data” and press OK button in the remote control.
4. After some seconds, “OK: 0” is displayed. In case of error, an explanation message is shown.
5. Reboot the TV to load the new settings.
2. Enter in service mode, select SmartLoader menu.
3. Select “Load data” and press OK button in the remote control.
4. After some seconds, “OK: 0” is displayed. In case of error, an explanation message is shown.
5. Reboot the TV to load the new settings.
Very important: All the TVs must have the same software version and hardware.
10. RS232 ADJUSTMENTS
The following information describes how to use RS-232 commands on the LE65x/75x series. We have also pro-
vided information on the adaptor cable required.
vided information on the adaptor cable required.
RS-232 cable
The LE65x/75x series do not support RS232 connectivity with a standard D-Sub 9 pin connector and instead use a
3.5mm jack input. To use this input for RS232 control it is necessary to adapt a connector cable. Please follow the
instructions below on how to construct the cable. Be sure that you use a commercial available RS232 to TTL 3.3V
level converter; nowadays there are a lot of USB-to-RS232 level converters on the market. You can fi nd some dif-
ferent models through FTDI company (www.ftdi.com).
The LE65x/75x series do not support RS232 connectivity with a standard D-Sub 9 pin connector and instead use a
3.5mm jack input. To use this input for RS232 control it is necessary to adapt a connector cable. Please follow the
instructions below on how to construct the cable. Be sure that you use a commercial available RS232 to TTL 3.3V
level converter; nowadays there are a lot of USB-to-RS232 level converters on the market. You can fi nd some dif-
ferent models through FTDI company (www.ftdi.com).
Please take a look on:
http://www.ftdichip.com/Support/Documents/DataSheets/Cables/DS_TTL-232R_CABLES.pdf
http://www.ftdichip.com/Support/Documents/DataSheets/Cables/DS_TTL-232R_CABLES.pdf
TV set signal requirement is shown in the below picture.
47
LC-39/50LE750
LC-39/50LE751
LC-39/50LE752
SOFTWARE UPGRADING
Ɣ
Ɣ
Ɣ
It is possible to update the software on your SHARP TV.
1
Add the binary file to USB memory root.
2
Insert the memory in any USB side TV set
socket.
socket.
3
Press
@ button.
4
With
Ż/Ź select Setup and press OK.
5
Select Control
ĺ Software ĺ Software
Update
ĺ Via USB.
Software update via USB
Ɣ
Ɣ
Ɣ
The next screen will appear:
The software version that is currently installed is
displayed.
displayed.
6 Press
V
button to proceed. The TV searches for
a new software file on the USB stick.
If a new software version is available after the
search, a message appears:
search, a message appears:
New software Vx.xx
7 Press
V
button to start loading the new software.
Or press END to end the wizard (the software will
not be updated).
not be updated).
•The updated percentage appears.
8 To make your TV completely ready for use again,
please switch it off and on with the mains switch.
Ɣ
Ɣ
Ɣ
If an Internet connection is available, new software can
be downloaded directly and installed in the TV set.
be downloaded directly and installed in the TV set.
1 Press
@ button.
2 With
Ż/Ź select Setup and press OK.
3 Select Control
→ Software → Software
Update
→ Via Internet.
A message regarding data protection will be
displayed.
displayed.
4 If you do not agree with data protection message,
please press
G
to exit. If you agree, please press
V
to continue.
The version of the software that is currently installed
will be displayed.
will be displayed.
5 By pressing
V
the TV connects to the Internet
and scans the update server for new software.
If a new software version is available, a message
appears.
appears.
6 Press
V
to start loading the new software.
If you want to end the wizard, please press END.
7 To make your TV completely ready for use again,
please switch it off and on with the mains switch.
NOTES
•
Please do not switch off the TV by the mains switch
during software updating.
during software updating.
•
The total programming process can take up to 50 minutes
in total.
Software update via Internet
“xxx.tli”
48
LC-39/50LE750
LC-39/50LE751
LC-39/50LE752
MAJOR ICs INFORMATION
1. General ICs Information
DUNTKF135WE (Main Unit)
IC 1505: HDMI Switch 3 inputs to 1 output.
Part number: BU16028KV (ROHM)
Sharp code: VHIBU16028K-1Q
http://www.rohm.com/products/databook/video/pdf/bu16006kv-e.pdf
Features:
Supports 2.25 Gbps Signaling Rate for 480i/p, 720p, and 1080i/p
Resolution to 12-Bit Color Depth.
Resolution to 12-Bit Color Depth.
Compatible with HDMI 1.3a.
5V Tolerance to all DDC and HPD_SINK Inputs.
Integrated Switchable 50
ΩΩReceiver Termination.
Integrated DDC buffer.
Integrated Equalizer circuit to adapt long cable.
IC 2701: Audio Power Amplifier.
Part number: STA333BW13TR (ST MICRO)
Sharp code: VHISTA333BW-1L.
http://www.st.com/internet/com/TECHNICAL_RESOURCES/TECHNICAL_LITERATURE/DATASHEET/CD00166760.pdf
Features:
Wide-range supply voltage, 4.5 V to 21.5 V.
Three power output configurations:
o 2 channels of ternary PWM (2 x 20 W into 8 Ω at 18 V) + PWM output.
o 2 channels of ternary PWM (2 x 20 W into 8 Ω at 18 V) + ternary stereo line-out.
o 2.1 channels of binary PWM (left, right, LFE) (2 x 9 W into 4 Ω +1 x 20 W into 8 at 18 V).
FFX with 100-dB SNR and dynamic range.
Scalable FFX modulation index.
Selectable 32- to 192-kHz input sample rates.
I2C control with selectable device address.
Digital gain/attenuation +48 dB to -80 dB with 0.5-dB/step resolution.
Soft volume update with programmable ratio.
Individual channel and master gain/attenuation.
Dynamic range compression (DRC) or anti-clipping
mode.
mode.
Audio presets:
o 15 preset crossover filters.
o 5 preset anti-clipping modes.
o Preset night-time listening mode.
Individual channel soft/hard mute.
Independent channel volume and DSP bypass.
I2S input data interface.
Input and output channel mapping.
Automatic invalid input-detect mute.
Up to 5 user-programmable bi-quads by channel.
Three coefficients banks for EQ presets storing with fast recall via I2C interface.
Bass/treble tones and de-emphasis control.
Selectable high-pass filters for DC blocking.
Advanced AM interference frequency switching and noise suppression modes.
Click on the first or last page to see other LC-39LE751EK (serv.man3) service manuals if exist.